Military Engineer Services - Madhya Pradesh

24982909 repair / maintenance of external water supply system at dscc ayodhya nagar , bhopal , excavation in trenches not exceeding 1 . 5 mtrs wide and not exceeding 1 . 5mtr in depth and getting out in hard / dense soil for taking out u / s clogged water pipe lines & relaying after cleaning / laying of new pipe lines , complete all as specified and directed . , returning filling in , including spreading , leveling , watering and well ramming in layers n exc 25 cm thick in hard / dense soil complete all as specified and directed . , removing surplus excavated soil n exc 50 mtr and depositing where directed at a level n exc 1 . 5 mtr above the starting point . , taking up or down ( from wall / trenches / floor ) existing steel tubing and connections , including cleaning for refixing or removal to store of following sizes: , ( a ) gi pipe 20 mm dia , ( b ) gi pipe 25 mm dia , ( c ) gi pipe 40 mm dia , ( d ) gi pipe 50 mm dia , refixing of old steel tubing and connections in new or old position including cleaning internally and externally , any grade / make in trenches / wall / floor / ceiling including all type of new fittings i . e . sockets , tee union elbow complete all as specified and directed for the follwing size , ( a ) gi pipe 20 mm dia , ( b ) gi pipe 25 mm dia , ( c ) gi pipe 40 mm dia , supply , fixing & laying gi tubing medium grade with one socket both end threaded in any length including cutting threading connection in new or old position and all type of gi new fittings for laid in trenches all as specified and directed of following size . , gi pipe 20mm dia bore , gi pipe 25mm dia bore , gi pipe 40mm dia bore , gi pipe 50mm dia bore , supply and fixing gun metal gate valves with iron wheel head screwed both ends for galvanised iron pipe of following sizes , including taking out old unserviceable gate valves , ( a ) 20mm dia , ( b ) 25mm dia , ( c ) 40mm dia , ( d ) 50mm dia , supply and fixing in replacement of float valve brass , high pressure with polythene float and fly nut complete screwed for iron pipe of following sizes . , ( a ) 25 mm dia , ( b ) 20mm dia , supply and fixing in repairs of rotational moulded pvc water storage tank of capacity 2000 ltrs cylindrical vertical with closed top including taking down of old broken / tank and making connection for new tank all as specified and directed by engr in charge . , ditto but 1000 litre capacity , ditto but 500 litre capacity , s&f in replacement top cover lid for pvc tank as per existing size / pattern , suitable for tank capacity 500 / 1000 / 2000 ltr . , 500 liters , 1000 liters , 2000 liters , supply and fixing in repair of foot valve assy with strainer of brass / gun metal of 50mm dia for suction pipe in u / g sump including taking out and lower the suction pipe all as directed by engr in charge . , supply , replacement and fixing cast iron sluice valve , heavy duty ( pn 1 . 6 ) with flanged ends , stainless steel spindle any pattern with iron wheel head conforming to is including jointing and jointing materials , nuts , bolts , rubber gasket and washers etc complete all as specified of following sizes . , ( a ) 100 mm bore , ( b ) 80 mm bore , ( c ) supply & fixing gland packing for motors . , m & l for repair / rewinding of submerssible pomp mono block type ac , 3 phase 5 hp , kirloskar model kvp 5684 after dismantling from its original position and disconnect from electric panel , opening the body , cutting , removing the burnt out winding and rewinding the same with appropriate supper enameled copper wire , insulating , varnishing drying etc and reassembling the motor . pump set including repair / replacement for pump set of all bearing , bush , nut , bolts , washers , coupling with pump and testing for best performance all as specified and directed by engr in charge . , m & l for repair / servicing of pump set suitable for ac , 3 phase , 7 . 5 hp by dismantling the pump case by opening the nuts & bolts and replacing the unserviceable impeller bearings and bush gasket , nut , bolts , washers including greasing , gland packing and rubber spacer incl transportation all as directed by engr in charge . , rewinding of 7 . 5 hp submersible pump set by removing old unserviceable copper winding clearing of slots and rewinding of submersible pump set with same gauge and no of turn of copper coil which is obtained from old winding and assembling complete all as specified and directed by engr in charge . , m&l for taking out of gi water tubing heavy grade of 50mm dia bore from existing bore well along with submerssible pumps , electric cable , wire rope etc for repairing of u / s submerssible pump , replacement of defective cable with the help of tripot , chain pulley and proper tools complete all as specified and directed by engr in charge . , m&l for taking out of gi water tubing heavy grade of 40mm dia bore from existing bore well along with submerssible pumps , electric cable , wire rope etc for repairing of u / s submerssible pump , replacement of defective cable with the help of tripot , chain pulley all as specified and directed by engr in charge . , supply , fixing of old submersible elctric cable pvc sheathed industrial 10 sqmm 3 core cable copper conductor including fitting with suitable lugs etc complete all as specifed and directed . , m & l for cleaning of underground sump by removing sludge , mud or any other foreign materials from the bottom and internal surface by wire brushing , drawn out water outside with portable pump sets and washing internally by using bleaching powder and applying 2 coats of white cement base paint and marking the date of cleaning complete capacity 50000 . 00 ltr with white paint on black background all as directed by engineer in charge for capacity of tank fifty thousand litre . note : ( i ) contractor shall be fully responsible for all security and sefty measures . contractor shall deploy experienced persons in such field with insurance from reputed insurance company and also submit the certificate . the engr in charge will ensure and certify the same before initiating payment . ( ii ) contractor shall ensure that during cleaning of tanks etc water supply system is not intrupted , accordingly adequate manpower shall be deployed to complete the job within the time period given by engr in charge . , ditto as above but of capacity 25000 ltrs , m & l for cleaning of over head water tank by removing sludge , mud or any other foreign material from the bottom and internal surface by wire brushing , draining out the water in the tank and washing internally by using bleaching powder and applying 02 coats of white cement base paint and marking the date of cleaning , complete capacity of the tank etc with fluorescent white paint on black background and all as directed by engineer in charge for capacity of tank one lakh litre . note : ( i ) contractor shall be fully responsible for all security and sefty measures . contractor shall deploy experienced persons in such field with insurance from reputed insurance company and also submit the certificate . the engr in charge will ensure and certify the same before initiating payment . ( ii ) contractor shall ensure that during cleaning of tanks etc water supply system is not intrupted , accordingly adequate manpower shall be deployed to complete the job within the time period given by engr in charge . , s & f in repair dol starter suitable for mono block type motor of capacity 5hp 3 phase , consisting relays & contactor , pre wiring , on / off of push button , 3 phase indicating neon lamp , overload relay system all as specified and directed by engr in charge . , s & f in repair semi autoamatic star delta starter suitable for 7 . 5 hp submersible motor , 415 volts , 50hz , 3 phase in sheet steel enclosure mb 2s type consisting relays & contactor , pre wiring , o...

Directorate Of Medical Education - Madhya Pradesh

24604803 tender invites for maintenance of hospital equipments fridgewith labour charges 3 mechenical work/stand 4 fridge painting charge 5 connector lead raplaced 6 door gas kit 7 thermostate replacement 8 compressor rewinder 9 compressor replacement 10 over load relay 11 relay replacement 12 gas charging 13 running capacitor 14 starting capacitor 15 thermo state 16 water cooler with labourcharges 17 fan motor rewinding 18 paint outside 19 paint inside 20 water tank leakage 21 fan blade replacement 22 knobe (each) 23 condencer coil repair 24 condencer cooling ccl repairing 25 fan capacitor 26 over load relay 27 thermostate replacement 28 running capacitor 29 starting capacitor 30 gas charging 31 compressor rewinder 32 compressor replacement 33 gezzer with labour charges 34 tank repairing nut screw etc 35 glass wood 36 neon lamp 37 3 core wire (per, meter) 38 thermostate raplaced 39 element raplacement 40 thermostate replacement 41 painting of tank 42 emergency light with labour charge 43 switch on/off 44 electronic pcb 45 tube rod 46 battery charging 47 power supply card replacement 48 lead 3 core (per meter) 49 switch board extension electric with labour charges 50 switch 5 amp 51 socket 5 amp 52 indicator lamp 53 power socket 15 amp 54 power switch 15 amp 55 wiring of board 56 pin top 57 3 core lead set (per meter) 58 voltage steplizer electric with labour charges 59 transformer rewinding 60 capacitor 61 tooggle switch 62 fuse holder 63 controller pcb circuit 64 relay replacement 65 power socket 15amp 66 3 core lead set (per meter) 67 exhaust fan/caling fan/stard fan with labour charges 68 fan motor rewinding 69 capacitor replacement 70 bearing set (2 nos) 71 shaft replacement 72 fan blade set 73 knobe for stand fan 74 3 core lead replacement 75 pyno switch 76 removing/fixing charges 77 rubber brush 78 fan regulator elactrical 79 fan regulator electronic 80 spotone lamps comptalux with labour charges 81 lamp replacement 82 holder replacement 83 wiring replacement 84 room cooler/desert cooler/small cooler with labour charges 85 rewinding of fan motor 86 replacement bush &shaft/bearing 87 3 core lead (per meter) 88 rotary switch 89 pump motor repairing 90 pump motor replacement 91 electrical wiring of cooler 92 stand wedling/wheel set etc 93 pvc pipe & destribution (set) 94 pad set replacement 95 shifting of cooler 96 regulator replacement 97 switch replacement 98 painting of cooler 99 air conditioner window/split unit with labour charges 100 running capacitor 101 starting capacitor 102 over load relay 103 compressor replacement 104 thermostate 105 compressor winding 106 gas filling charges 107 blower motor winding 108 condencer repair 109 cooling coil repair 110 replacement bush & shaft/bearing 111 service charges 112 water purifier (acquaguard) with labour charges 113 per filter candel 114 carbon 115 u v tube 116 top buttom filter 117 togle switch 118 bipper circuit repair 119 fuse holder 120 connecting lead 121 pcb repaire 122 new pcb 123 water tube replacement 124 minor works aluminium carpenter work with material and labour charges 125 board sunmica per sq. fit 126 ply board up to 8 mm 127 woden rafter 128 carpenter charges per day per carpenter 129 ragzine per mtr. 130 aluminium partition work per sq. fit 131 handle replacement 132 door closer replacement 133 wooden table repair each 134 chair repair each material labour both 135 door stopper replacement 136 glass for office table per sq. fit 137 plain glass per sq. fit with labour 138 curtain pipe per sq. fit 139 false celling pre sq. fit 140 door window repair screening per sq. fit 141 electrical works with material and labour charges 142 open serface wiring pvc pipe per mtr. 143 sub main distribution board repair 144 main board 3 phase work per board 145 tube light rod/chowk/starter fitting labour charges 146 exhaust fan fitting charges 147 cilling/wall fan fitting charges 148 tube light complete fitting (new) 149 cilling fan painting work 150 cable laying upto 25 sq. cable per mtr. 151 concealed wiring 3 phase (per power point) 152 switch round type 5 amp 153 socket round type 4 amp 154 switch /socket flesh type 5 amp 155 switch/socket flesh type 15 amp 156 pvc casecing caping/pvc pipe upto 3/4 157 copper wire upto 1.5 squre mm (per meter) 158 sunmica board up to 10×12? per board 159 replacement of mcb (per unit) 160 replacement of fuses up to 63 amp 161 power combined s/s with board 162 three pole mcb 163 lose wire drese up 164 four pole mcb 165 strite light fitting complete 166 inventer repairing 167 engine oil replacement 168 air filter 169 carbon brush per set 170 alternator rewinding 171 machanical work column aligament gressing 172 fuel pump repair 173 rocker arm 174 valve 175 portable honda petrol generator repair 176 dg set up 7.5 kva 177 dg set 300 kva 178 water lifting pump with labour charges 179 rewinding of motor up to 15 hp 180 capacitor replacement 181 pump unit repair 182 cleaning & painting 183 football replacement 184 empler replacement 185 servicing oiling & greassing charges 186 bearing replacement 187 single phase privetor (safety instrument) 188 main switch 3 phase 63 amp 189 star delta stator repair charges 190 over load replacement 191 rewinding of motor above 15 hp 192 wiring of motor control board 193 bearing replacement above 15 hp 194 servising of motor above 15 hp 195 plumbing work including material and labour charges 196 1/2? gi pipe line per mtr 197 1? gi pipe line per mtr 198 albow, tee, band, replacement each 199 tape replacement each 200 plumber per day charge 201 gi pipe line up to 1? per meter 202 tank flot valve each 203 old 204 denting/painting work including trasportation charges labour shifting charge 205 denting and painting steel almiras 206 denting and painting of stool, overbed trolly 207 denting and painting of bedside locker 208 denting and painting of bed 209 denting and painting of table 210 replacement of m.s. sheet 211 hardware replacement by new 212 old bed replacement by new 213 old bed side replacement new one 214 inverter repairing with labour charges 215 power supply card replacement 216 charging circuit pcb 217 main transformer & change over relay 218 socket replacement 219 copper lead replacement 220 battery replacement 221 indication pcb replacement 222 battery connector each 223 battery water lable check 224 mechanical/febrication work including labour and transportation charges 225 steel almiras locks repair/ replacement 226 welding work 227 sheet metal work 228 duplicate key for locks 229 grils febration work per kg 230 almira foot repair replacement 231 asbestous green shade per sq. fit 232 old oiron scrap each kg. 233 kachra troly repairing denting wheel handle 234 baby wormer 235 element 236 bulb 237 tempreture control modle 238 switch 239 wire 240 holder 241 phototherapy machine 242 uv light tube 243 white tube 244 chowk 245 cooling fan 246 tube side holder 247 main lide 248 stand type with labour charges 249 wire 3 core replacement 250 lamp, bulb replacement 251 painting of lamp 252 lamp holder replacement 253 three pin top replacement 254 audio system with labour charges 255 ahuja horn sp 6201 td 256 ahuja wall speaker bs 6082 t 257 ahuja amplifier ssb 60 258 ahuja microphone sem 66 ch 259 cabling microphone speaker 260 miscellaneous work with labour charges 261 foam beds parachte rubberized cover size 6×3 replacement 262 radium work 263 rate per sq. fit 264 painting work 265 rate per sq. fit 266 gate pass token 267 plastic token 4?, 6? 268 name plate/photo id 269 rate per plate 270 complate kitchen troly (new) 271 sadodes lamp repair 272 o.t. light repair and bulf 273 s.s. drums repair/labour charges 274 hings set replacement 275 lock set replacement 276 revinting work 277 kadi kunda set 278 welding work (1set) 279 stretcher trolly with labour charges 280 wheel replacement 281 oiling & gressing 282 painting work with paint 283 saft & bush replacement 284 top sheet replacement 285 wheel chair with labour charges 286 wheel replacement 287 saft & bush replacement 288 cycle wheel aligement (1set) 289 spoke replacement (1set) 290 iv set/02 stand/cortan stand with labour charges 291 wheel replacement 292 oiling & gressing 293 welding work 294 painting wire 295 semifowler bed with labour charges 296 lever replacement 297 wheel replacement 298 house keeping trolly with labour charges 299 wheel replacement 300 oiling & gressing 301 welding work 302 painting wire 303 kitchen trolly with labour charges 304 wheel replacement 305 oiling & gressing 306 welding work 307 painting wire 308 rail cot eclampsia beds 309 level replacement 310 wheel replacement 311 labour table with labour charges 312 replacement of parts 313 ss sheets replacement 314 bed side treatment folder 315 jumbo oxygen cylinder 316 hy pressure auto clave m/c with labour charges 317 contractor coil three phase 318 glass tube 12 inch 319 door alen bolt/hinze 320 water tank gas kit 321 release valve 322 water tank leakage 323 pressure meter big 324 contractor three phase 325 toggle switch 15 amp. 326 wireing for three phase connection 327 mechanical work 328 pressure control valve 329 welding work 330 release valve gas kit 331 autoclave small size with labour charges 332 contractor coil three phase 333 glass tube 12 inch 334 door alen bolt/hinze 335 water tank gas kit 336 release valve 337 water tank leakage 338 pressure meter big 339 contractor three phase 340 toggle switch 15 amp. 341 wireing for three phase connection 342 mechanical work 343 pressure control valve 344 welding work 345 release valve gas kit 346 strelizer machine with labour charges 347 tank leakage repair 348 element 1000 2000 walt 349 ketal contractor 350 wire three core (per meter) 351 three pin top 15 amp. 352 suction m/s electronic food with labour charges 353 fiter set 354 pump unit & flage 355 wheel sets 356 painting of machine 357 bottle/jar replacement 358 new motor replacement 359 motor winding 360 toggle switch 15 amp. 361 rubber tubeing 362 suction pump dial meter 363 servicing of motor 364 three core lead (per meter) 365 bottle rubber gas kit 366 capacitor replacement 367 over flow valve 368 b.p. instrument with material and labour charges 369 rubber tubeing 370 spacial bulb 371 metallic valve 372 hings set 373 washer filter set 374 cuff replacement 375 mercury filling 376 connector tube 377 ecg machine with labour charges 378 five core shelded cable repair 379 amplifier ckt repair 380 styless with base 381 clip set 382 ecg bulb with electrode 383 new ecg cable 384 power circuit card 385 repairing of cable 386 cable connector 387 boys apparators with labour charges 388 breathing bag 389 backet dia pharm 390 non returnoutlet 391 solder screw nut/washer 392 york blander 393 york (for oxi brass body) 394 circuit adopter 395 guage meter n2 02 396 halothane bottle 397 corrungatated breathing tube 398 anatomical with pads 399 new pin valve 400 full servicing & calilbration 401 flow washer 402 emergency circuit 403 halothane washer 404 cylinder washer 405 new pin set 406 pressure release valve 407 low/high pressure diaform 408 seafty valve 409 replacement of nippels 410 cylender studes 411 cut of regulator diapharm 412 weighting machine baby/adult with labour charges 413 spring replaced 414 power supply of m/c 415 display unit repair 416 calibration of m/c 417 dial repairing 418 x ray machine with labour charges 419 x ray tube repairing oil fillings 420 vaccum process with labour charges 421 oil replacement 422 h.t. cable replacement 423 h.t. transformer repairing 424 control panel repairing 425 electric timer 426 fuse holder 427 glass fuse (each) 428 exposure switch 429 new x ray tube head 300 ma 430 4 core wire (per meter) special wire 431 for anode rotating circuit 432 receptical replacement 433 indicator lamps (each) 434 table fitting motors 435 limit switch (each) 436 ma switch 437 ma selector switch 438 ma switch 439 mechanical work colum aligement gressing 440 bearing replacement etc 441 wheel replacement 442 coti meter bulb replacement 443 o.t. table with labour charges 444 tank hydrolic gas kit 445 bearing replacement 446 welding work 447 greassing 448 gear problem 449 gas kit of piston 450 cleaning oil replacement per litre 451 hydrolic oil replacement per litre 452 pump washer set 453 hydrolic problem valve 454 lead screw 455 top sheet replacement 20 guage 456 top sheet replacement aluminium 457 centrifuge machine with labour charges 458 rewinding of motor 459 new motor replacement 460 carbon brush (set) 461 timer electric regulator 462 lead 3 core (per meter 463 rotary switch 464 rpm meter 465 fuse holder with fuse 466 commulater with armature 467 manual regulator 468 motor aligement 469 bearing set (pair one) 470 tube holder 471 motor base replacement 472 gas kit 473 rpm controler 474 tube 1 no. 475 microscope 476 co axile (r&p) 477 prizm monocator 478 prizm set (new) 479 eye places servicing 480 mechanical stage 481 slide clip 482 complete servicing 483 lence clip 484 mirror with holder 485 mirror (reflector) 486 gear box/slight 487 obiceher fall servicing 488 oil immersion servicing 489 incind full servicing 490 monocular full servicing 491 binocular full servicing 492 vaccum process with labour charges 493 hardware oil greassing 494 fumigater with labour charges 495 motor winding 496 disc plate 497 lead set 498 fan 499 ovume lab/incubator oven with labour charges 500 door gas kit 501 handle for door 502 toggle switch 503 lead indicator 504 cable 3 core (lead) 505 heater element (sterlizer) 506 1000 walts 507 1500 walts 508 2000 walts 509 insutation material 510 thermostate replacement 511 30 to 110 deg 512 50 to 300 deg 513 wiring by glass wire 514 indicator lamps 515 piped oxygen supply with labour charges 516 copper pipe replacement per meter 517 flow meter unit 518 oxygen outlet 519 suddle 520 isolation valve 521 elbow 522 t piece 523 manifold single 524 manifold double 2×2 525 tail pipe 526 non return valve 527 jumbo oxygen cylinder/carbon 50 litres 528 electric cautery with labour charges 529 bipolar electrode 530 foot switch 531 cautery plate 532 male and female electrode connector 533 any other 534 vantilator 535 front pannel 536 main band 537 power supply board 538 battery 539 sensor 540 tube 541 lcd display 542 18. pulse oxymeter 543 sp o2 finger probe 544 lcd display 545 battery 546 main band 547 power supply 548 cardiac monitor (schiller) 549 sp 02 finger probe 550 ecg pro 551 main band 552 ecg module 553 nib p cuff 554 nib module 555 power supply 556 battery 557 x ray view box 558 sheet replacement 559 light replacement 560 ppm charge 561 laproscope 562 power supply 563 cooling fan 564 lence ...

Military Engineer Services - Madhya Pradesh

21476592 repair / maintenance of lt overhead lines , cables , capacitor panel , lt panel at dronachal bhopal , excavation in trenches in any type of soil exceeding 1 . 5m deep and not exceeding 1 . 5 m wide and getting out complete all as specified and directed . , returning , filling in including spreading , levelling , watering and well ramming excavated soil in layers not exceeding 25 cm thick each , back in trenches after cables have been laid and tested , poles , stays , struts have been erected and tested , all as specified and directed at site . , removing excavated surplus soil ( soft / hard soil ) obtained from excavation to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1 . 5m above the starting point all as specified and directed . , supply and laying sand cushioning for cable protection in trenches before laying cable and 15 cm deep over the cable all as specified . note : only punned thickness will be measured . , supply laying bricks old size sub class b bricks common bumt bldg bricks laid in trenches for cable protection compete , all as specified & directed by engr in charge . , m&l for plain cement concrete 1:3:6 type c 2 using 40mm graded stone aggregate in foundtion of pole / stay assembly etc including necessary form work , all as specified and directed . , m&l for plain cement concrete 1:2:4 type b 1 using 20mm graded stone aggregate for coping around poles , including necessary form work finishing even and smooth without using extra cement , with two coat of lime wash on coping and all as specified and directed . , taking down old insulator any type and make from existing over head line and poles / stay after dismantling electrically , supply & fixing pin type insulator including one galvanised mild steel spindle , two galvanised iron waqsher and one galvanised iron nut100 x 65 mm dia for 1100 v grade . , supply & fixing shackle type insulator incl one galvanised mild steel spindle , two galvanised iron waqsher and one galvanised iron nut75 x 90 mm dia for 1100 v grade . , restraining of existing acsr conductor on lt over head line on the poles without taking down of acsr from over head line by disconnecting and untying from insulator and retying with new binding wire , rejoining of service connection of street light , and all other jumper connection complete all as specified and as directed . note : three run of phase conductor one run of neutral conductor and one run of strret light conductor will be measured as one length . , m&l cutting pcc / floor / road and taking out cable and making good , including material as per existing after laying of pipe for cable protection all as specified and directed size of trench not more than 0 . 30 x 0 . 30 cm . , s&f in replacement of gi pipe medium grade on wall / floor for cable protection with fixing arrangement size 100 mm dia . , s&f in replacement of gi pipe medium grade on wall / floor for cable protection with fixing arrangement size 80mm dia . , s&f in replacement of gi pipe medium grade on wall / floor for cable protection with fixing arrangement size 50mm dia . , taking out old unserviceable lt under ground cable of any size and rating . , laying only xlpe / pvc insulated pvc sheathed heavy duty armored electric under ground cable aluminum conductor 1100 volts grade in trenches / on pole through sleeves etc . all as specified and directed , ( a ) cross sectional area 120 sqm 3 1 / 2 core . , taking down existing cable and refixing the same in existing postion or other location of any size , supply and laying xlpe heavy duty armoured electric under ground cable aluminum conductor 1100 volts grade in trenches / on pole through sleeves etc . all as specified and directed , ( a ) cross sectional area 50 sqm 31 / 2 core . , ( b ) cross sectional area 35 sqm 31 / 2 core . , ( c ) cross sectional area 25 sqm 4 core . , ( d ) cross sectional area 16 sqm 4 core . , ( e ) cross sectional area 10 sqm 4 core . , m&l for spray painting with one coat of synethetic enamel paint for outdoor & indoor panel board outer & innner side with two coat of lime wash on plinth of panel board including connected accessories in any size and welded hingeg , locking arragement complete all as specified and directed by engineer in charge , supply and replace mccb , 4 pole , 50 hz capacity ( thermal adjustable type ) all as specified and directed , for following capacity , ( a ) 400 amps with 36 ka rupturing capacity , ( b ) 250 amps with 25 ka rupturing capacity , ( c ) 200 amps with 25 ka rupturing capacity , ( d ) 160 amps with 25 ka rupturing capacity , ( e ) 100 amps with 36 ka rupturing capacity , supply and replace mccb , 3 pole , 50 hz capacity 36 ka rupturing capacity ( thermal adjustable type ) all as specified and directed , for following capacity , ( a ) 250 amps , ( b ) 100 amps , trimming / cuting of trees / branches coming in route of ht / lt overhead electrical lines at various location and dumping / staging 50 mtr from existing point all as specified and directed by enginner in charge . , ( a ) above 200mm to 500 dia , ( b ) branch of 200mm dia , ( c ) branch of 150mm dia , ( d ) branch of 100mm dia , ( e ) branch upto 80mm dia , trimming / cuting of bushes and grass of substations / mes installations and surrounding of panel board feeder piller boxes at various location and dumping / staging 50 mtr from existing point all as specified and directed . , supply and fix in repair lt cable joiniting kit 1100volts grade cable for straight through joint heat shrink type complete with jointing material and accessories suitble for 4 core xlpe armoured aluminium conductor cable of size 16 to 120 sqmm , s&f , out door feeder pillar box weather & vermin proof suitable ventilated 3 phase , 4 wire , 440 volts , 50 hz , factory assemble & factory fabricated and compartmentalised out of 3 . 15 mm thick sheet steel duly powder coated paint over one coat of red oxide zinc chrome primer , with bus bar chamber to accommodate epoxy painted high conductivity copper bus bar of capacity 250 amps ( 3 ph , 4 wire ) including digital type multi functional meter to measure voltage 0 500 volts & 0 100 amps with suitable cts phase indication neon lamps , necessary glands cable connection with proper lugs , pcc foundation & pedestal for fixing feeder pillar box with required pcc work in fondation with pcc ( 1:2:4 ) type b1 using 20 mm graded stone aggregate and plastering 15 mm thick in cm ( 1:6 ) and including following accessories complete : incoming ( a ) mccb , 4 pole , 415 volt , 200 amp , 25 ka 01 nos . out going ( a ) mccb , 4 pole , 415 volt , 100 amp , 10 ka 01 nos ( b ) mcb sp 25 amp 230 volt , 10 ka 05 nos ( c ) mcb sp 20 amp 230 volt , 10 ka 12 nos ( d ) mcb sp 16 amp 230 volt , 10 ka 8 nos note: ( i ) make of lt panel : juhi / deor / bspl / mc layer ( ii ) drawing of panel to be got approved from age e / / m before procurement . , s&f in repair of automatic street light switch three phase with nature switch 03 ( dual output ) as the controlling unit for automatic switching of street lights based on lux level of natural light . the sensor ( nature switch ) along with suitable power contractor , mcb and support terminals should be enclosed in pole / wall mountable enclosure made of rust proof , electric shock proof , termite proof and fr grade special moulding compound ( sintex make smc junction box ) confirming to ip54 . the contractor , mcb and circuit wiring should suitable enough to take load 5 kw equally distributed over 3 phase ( 4 kw / phase ) . the contractor rating 25 amps ( 4 pole ) and mcb ( single pole ) rating : 20 25 amps ( sp 03 nos ) , complete all as specified and directed . make . nature switch model no swadeep 02ec 5 kw3p ( dual ) or equivalent makes in legrand / l&t / ge . , taking o...

Military Engineer Services - Madhya Pradesh

21239611 repair / maintenance of lt overhead lines , cables , capacitor panel , lt panel at dronachal bhopal , excavation in trenches in any type of soil exceeding 1 . 5m deep and not exceeding 1 . 5 m wide and getting out complete all as specified and directed . , returning , filling in including spreading , levelling , watering and well ramming excavated soil in layers not exceeding 25 cm thick each , back in trenches after cables have been laid and tested , poles , stays , struts have been erected and tested , all as specified and directed at site . , removing excavated surplus soil ( soft / hard soil ) obtained from excavation to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1 . 5m above the starting point all as specified and directed . , supply and laying sand cushioning for cable protection in trenches before laying cable and 15 cm deep over the cable all as specified . note : only punned thickness will be measured . , supply laying bricks old size sub class b bricks common bumt bldg bricks laid in trenches for cable protection compete , all as specified & directed by engr in charge . , m&l for plain cement concrete 1:3:6 type c 2 using 40mm graded stone aggregate in foundtion of pole / stay assembly etc including necessary form work , all as specified and directed . , m&l for plain cement concrete 1:2:4 type b 1 using 20mm graded stone aggregate for coping around poles , including necessary form work finishing even and smooth without using extra cement , with two coat of lime wash on coping and all as specified and directed . , taking down old insulator any type and make from existing over head line and poles / stay after dismantling electrically , supply & fixing pin type insulator including one galvanised mild steel spindle , two galvanised iron waqsher and one galvanised iron nut100 x 65 mm dia for 1100 v grade . , supply & fixing shackle type insulator incl one galvanised mild steel spindle , two galvanised iron waqsher and one galvanised iron nut75 x 90 mm dia for 1100 v grade . , restraining of existing acsr conductor on lt over head line on the poles without taking down of acsr from over head line by disconnecting and untying from insulator and retying with new binding wire , rejoining of service connection of street light , and all other jumper connection complete all as specified and as directed . note : three run of phase conductor one run of neutral conductor and one run of strret light conductor will be measured as one length . , m&l cutting pcc / floor / road and taking out cable and making good , including material as per existing after laying of pipe for cable protection all as specified and directed size of trench not more than 0 . 30 x 0 . 30 cm . , s&f in replacement of gi pipe medium grade on wall / floor for cable protection with fixing arrangement size 100 mm dia . , s&f in replacement of gi pipe medium grade on wall / floor for cable protection with fixing arrangement size 80mm dia . , s&f in replacement of gi pipe medium grade on wall / floor for cable protection with fixing arrangement size 50mm dia . , taking out old unserviceable lt under ground cable of any size and rating . , laying only xlpe / pvc insulated pvc sheathed heavy duty armored electric under ground cable aluminum conductor 1100 volts grade in trenches / on pole through sleeves etc . all as specified and directed , ( a ) cross sectional area 120 sqm 3 1 / 2 core . , taking down existing cable and refixing the same in existing postion or other location of any size , supply and laying xlpe heavy duty armoured electric under ground cable aluminum conductor 1100 volts grade in trenches / on pole through sleeves etc . all as specified and directed , ( a ) cross sectional area 50 sqm 31 / 2 core . , ( b ) cross sectional area 35 sqm 31 / 2 core . , ( c ) cross sectional area 25 sqm 4 core . , ( d ) cross sectional area 16 sqm 4 core . , ( e ) cross sectional area 10 sqm 4 core . , m&l for spray painting with one coat of synethetic enamel paint for outdoor & indoor panel board outer & innner side with two coat of lime wash on plinth of panel board including connected accessories in any size and welded hingeg , locking arragement complete all as specified and directed by engineer in charge , supply and replace mccb , 4 pole , 50 hz capacity ( thermal adjustable type ) all as specified and directed , for following capacity , ( a ) 400 amps with 36 ka rupturing capacity , ( b ) 250 amps with 25 ka rupturing capacity , ( c ) 200 amps with 25 ka rupturing capacity , ( d ) 160 amps with 25 ka rupturing capacity , ( e ) 100 amps with 36 ka rupturing capacity , supply and replace mccb , 3 pole , 50 hz capacity 36 ka rupturing capacity ( thermal adjustable type ) all as specified and directed , for following capacity , ( a ) 250 amps , ( b ) 100 amps , trimming / cuting of trees / branches coming in route of ht / lt overhead electrical lines at various location and dumping / staging 50 mtr from existing point all as specified and directed by enginner in charge . , ( a ) above 200mm to 500 dia , ( b ) branch of 200mm dia , ( c ) branch of 150mm dia , ( d ) branch of 100mm dia , ( e ) branch upto 80mm dia , trimming / cuting of bushes and grass of substations / mes installations and surrounding of panel board feeder piller boxes at various location and dumping / staging 50 mtr from existing point all as specified and directed . , supply and fix in repair lt cable joiniting kit 1100volts grade cable for straight through joint heat shrink type complete with jointing material and accessories suitble for 4 core xlpe armoured aluminium conductor cable of size 16 to 120 sqmm , s&f , out door feeder pillar box weather & vermin proof suitable ventilated 3 phase , 4 wire , 440 volts , 50 hz , factory assemble & factory fabricated and compartmentalised out of 3 . 15 mm thick sheet steel duly powder coated paint over one coat of red oxide zinc chrome primer , with bus bar chamber to accommodate epoxy painted high conductivity copper bus bar of capacity 250 amps ( 3 ph , 4 wire ) including digital type multi functional meter to measure voltage 0 500 volts & 0 100 amps with suitable cts phase indication neon lamps , necessary glands cable connection with proper lugs , pcc foundation & pedestal for fixing feeder pillar box with required pcc work in fondation with pcc ( 1:2:4 ) type b1 using 20 mm graded stone aggregate and plastering 15 mm thick in cm ( 1:6 ) and including following accessories complete : incoming ( a ) mccb , 4 pole , 415 volt , 200 amp , 25 ka 01 nos . out going ( a ) mccb , 4 pole , 415 volt , 100 amp , 10 ka 01 nos ( b ) mcb sp 25 amp 230 volt , 10 ka 05 nos ( c ) mcb sp 20 amp 230 volt , 10 ka 12 nos ( d ) mcb sp 16 amp 230 volt , 10 ka 8 nos note: ( i ) make of lt panel : juhi / deor / bspl / mc layer ( ii ) drawing of panel to be got approved from age e / / m before procurement . , s&f in repair of automatic street light switch three phase with nature switch 03 ( dual output ) as the controlling unit for automatic switching of street lights based on lux level of natural light . the sensor ( nature switch ) along with suitable power contractor , mcb and support terminals should be enclosed in pole / wall mountable enclosure made of rust proof , electric shock proof , termite proof and fr grade special moulding compound ( sintex make smc junction box ) confirming to ip54 . the contractor , mcb and circuit wiring should suitable enough to take load 5 kw equally distributed over 3 phase ( 4 kw / phase ) . the contractor rating 25 amps ( 4 pole ) and mcb ( single pole ) rating : 20 25 amps ( sp 03 nos ) , complete all as specified and directed . make . nature switch model no swadeep 02ec 5 kw3p ( dual ) or equivalent makes in legrand / l&t / ge . , taking o...