West Central Railway - Madhya Pradesh

40816000 supply of heat detector (parts no.2ed 245 3544) for spare parts of automatic smoke/fire detection with alarm system as per rdso specification no. rdso/2013/cg 06 (rev 2) amdt 1.heat detector (parts no.2ed 245 3544) for spare parts of automatic smoke/fire detection with alarm system as per rdso specification no. rdso/2013/cg 06 (rev 2) amdt 1.,heat detector (parts no.2ed 245 3544) for spare parts of automatic smoke/fire detection with alarm system as per rdso specification no. rdso/2013/cg 06 (rev 2) amdt 1. [ warranty period: 30 months after the date of delivery ]...

West Central Railway - Madhya Pradesh

40794116 supply of heat detector (parts no.2ed 245 3544) for spare parts of automatic smoke/fire detection with alarm system as per rdso specification no. rdso/2013/cg 06 (rev 2) amdt 1.heat detector (parts no.2ed 245 3544) for spare parts of automatic smoke/fire detection with alarm system as per rdso specification no. rdso/2013/cg 06 (rev 2) amdt 1.,heat detector (parts no.2ed 245 3544) for spare parts of automatic smoke/fire detection with alarm system as per rdso specification no. rdso/2013/cg 06 (rev 2) amdt 1. [ warranty period: 30 months after the date of delivery ]...

Bharat Sanchar Nigam Limited - Madhya Pradesh

40534002 tender for comprehensive maintenance, upkeep and operation of electro mechanical services of te building and staff quarters at shivpuri under ba gwalior.; 2 comprehensive maintenance of following electromechnical services as per the asset details, specification and conditions attached and providing one semi skilled labour for upkeep, repair and operation in general shift only. ( a ) e.i. & fans. ( b ) compound lighting ( c ) pumps ( d ) sub station ( e ) e. a. sets ( f ) a.c. system ( g ) fire detection system ( h ) electrical appliances. 3 a ) labour component for upkeep, repair and operation of ems ( one semi skilled labour in general shift per month ) 4 b ) comprehensive maintenance of ems 5 sh ii: preventive maintenance and consumable items as and when required on measurable basis 6 servicing & routine maintenance ( b check ) of followingcapacity of dg set complete with cleaning of air cleaner element, replacement of engine lube oil of proper grade ( seal pack of reputed make ) , replacement of lube oil filter elements, replacement of fuel filter elements, retighten cylinder head nuts, adjust engine valve clearance, replacement of radiator water by fresh distilled water with addition of coolant additive concentrate, cleaning of radiator fins, drain sediments from water separator, check inlet air restriction, check air piping, belt tensions i / c cleaning & dedusting of alternator, control panel, fuel tank, tightening & maintaining of all hose connections, electrical connections, battery connections etc & actual load testing of dg set after servicing etc as directed. 7 i ) 125 kva dg sets 8 supply , installation, testing and commissioning of 12 volt, heavy duty , hybrid alloy plate, semi maintenance free , storage type, ready to usebattery set for existingdeasetincludingproper initial factory charging of unit, providing and fixing, terminal and thimbles ( if required ) , greasing the battery terminalscomplete as required.180 ah, 12 volt ( m / s exide fxpo xp180 or equivalent of approved make ) note 1 ) agency shall consider rebate for old battery while quoting of rates. additional requirement to be borned by agency without extra cost. 9 dehydration / filtration of oil of transformer, ht panel and potential transformer along with break down voltage testing before and after filtration, acidity testing after filtration, silica gel change complete as required.note1 ) breakdown voltage of oil after dehydration / filtration shall be minimum 60 kv rms.2 ) total acidity max after dehydration / filtration shall be 0.05 mg koh / gm.3 ) max water content after dehydration / filtration shall be 15 ppm. 10 sh iii: one time maintenance of ems asrequired on measurable basis as per instruction of engineer in charge ( for removal of initial defects in services ) 11 replacement of the following faulty / burnt electrical items / accessories in the existing substation and distribution system, suitable for operation on 3 phase, 33kv / 415v / 230v, 50hz, ac supply system including cleaning of installation and lt panels and distribution boards etc complete with interconnections, testing and commissioningas reqd at site. 12 630 amps. hrc fuse. 13 transformer oil. 14 acsr conductor jumper up to 3.0 mtrs. length. 15 gang operated air break switch in the existing 200 kva , 33 kv outdoor substation complete. 16 threephase lcd multifunction meter indicating v, a, f, pf, power, energy ( m / s l&tnova series, cat. no. wm30kfc3c00 or equivalent similar superior make with c.ts 17 led type indication lampswith suitable rating hrc fuses with base & carrier ( led ofm / s esbee l&t, elr&y240a 240v + elb240a 240v ac or equivalent similar superior make ) 18 providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 19 100 amp rating, four pole, mccb with variable thermal magnetic release, ( release range 25 32, 50 63, 80 100a ) breaking capacity 25ka at 415v, 50hz, ac supply and conforms to is / iec 60947 2 ( make and model , m / s l&t dn0 100c or equivalent similar superior make ) with ( ics = 100% icu ) 20 repairing of the existing old and damaged foundation i / c white washing etc. complete as required. 21 painting of the existing ht poles ( 06 nos. ) i / c its cross arms / members etc. complete as required. 22 earthing with g. i. earth plate 600mmx600mmx6mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal / coke and salt as required. ( for neutral earthing of the existing transformer ) . 23 providing and fixing 25mmx5mm g. i. strip in 40 mm dia g. i. pipe from earth electrode i / c connection with g. i. nut, bolt, spring washer, excavation and re filling etc. as required. 24 providing and fixing 25mmx5mm g. i. strip on surface or in recess for connections etc. as required. 25 replacement of the following faulty / burnt / damaged electrical items / accessories suitable for operation on 230v / 415v, 50hz, single / three phase ac supply , in the existing electrical installation , fan and fittingsi / c supplying making interconnections, testing & commissioning etc. complete as required: 26 electronic choke for 36 / 40 watt fluorescent lamp . 27 30 watt led lamp with holder ( for campus light ) . 28 1200 mm ( nominal ) size, 40 watt fluorescent tube rod. 29 2.5 mfd condenser ( for ceiling fans ) . 30 9 watt led bulb with holder. 31 20 watt led lamp with holder ( for campus light ) . 32 1200 mm ( nominal ) size, 20 watt led tube rod 33 6 32 amps. single pole c curve mcb. 34 32 amps. triple pole and neutral mcb. 35 starter for 4feet, 40 watt fluorescent fitting. 36 5 / 6 amps piano type switch 37 15 / 16 amp piano type switch 38 3 pin 5 / 6 amp socket outlet 39 6 pin 15 / 16 amp socket outlet 40 supplying and fixing two module stepped type electronic fan regulator. 41 supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel / pvc conduit as required 42 1 x 1.5 sq. mm 43 2 x 4 sq. mm 44 supplying and laying 2x4 sqmm. al. pvc insulated and pvc sheathedunarmoured cable in the existing surface / recessed steel / pvc conduit as required 45 repairing / rewinding of the following faulty electrical items / accessories complete with connections, testing and commissioning etc. as reqd: 46 rewinding of 1200 / 1400 mm. sweep ceiling fan. 47 rewinding of 450 mm. sweep exhaust fan. 48 supply, installation, testing and commissioning of following rating and types of prewired fitting complete with all accessories driver and lamps etc., suitable for operation on 230 volts, 50 hz single phase ac supply i / c fixing the same directly on wall / celling including connection with 3x 1.5 sqmm frls pvc insulated copper conductor flexible cable etc as required. ( m / s. bajaj / havells / philips ) . 49 1200 mm ( nominal ) , 20 watts ( + / 2 watts ) energy efficient linear box led batten light having 6500k colour temp., minimum 1900 lumens, 95 lumen / watt efficacy and 0.9 power factor . 50 replacement of the old, life expired fittings with the following rating and type fitting suitable for operation on 230volts, 50 hz, single phase, ac supplyi / c installation the same on the existing bracket on the wall / pole, making interconnections, testing, commissioning etc as reqd at site . ( preferred makes syska / wipro / havells / crompton / bajaj / osram or similar superior make ) . 51 led street light luminaire of nominal wattage 30w ± 15% with aluminium housing & lens embedded pc cover having ip65 protection. 52 led street light luminaire of nominal wattage 60w ± 15% with aluminium housing & lens embedded pc cover having ip65 protection. 53 providing and fixing of 300 mm sweep, 1400 rpm domestic exhaust fan suitable for operation on 1 phase, 50 hertz, 220 230 volt ac supplyin existing opening as reqd. ( crompton, bajaj, havells, almonard or s.s.make ) 54 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current ( bldc ) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value ( cm / m / w ) minimum 6.00, air delivery minimum 210 cum / min , 350 rpm ( tolerance as per is : 374 2019 ) , thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c ( max. ) , insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 55 sh iii: pumps & lt panels 56 sitc of dol motor starter with overload protection and single phase preventor , suitable for operation upto 7.5 hp, 415 volts, 50hz, three phase, monoblock pump set having suitable rating contactor, relay, voltmeter, ampere meter, on / off push button assembly, indicators, connection plate, etc. complete as required. ( m / s. l&t mu c6 dol starter, bch or similar superior make ) . 57 supplying and fixing of 3ph led ammeter accuracy class 1.0 and suitable rating cts complete as required 58 supplying and fixing of 3ph led ammeter accuracy class 1.0. complete as required. 59 sh iv: sac & pac units 60 servicing of existing one no 7 tr capacity high precision air conditioner unit with necessary dismantling of covers wherever required, pressurized wet servicing of evaporator and condenser coil, cleaning of oil stains if any, cleaning of evaporator filters with water , checking / inspection of all the electrical components and connections for its tightness, checking of electrical parts for proper functioning, checking out all controls, minor rectification of damaged indoor and out door wiring for satisfactory operation of package ac unit, including visit and inspection charges complete in all respect , testing and commissionetc. complete as required at site. 61 supplying and top up charging of fresh refrigerant r 22 / m 22 / c 407in the existing window ac / split ac / package ac units unitcomplete as per manufacturer / departmental specifications, etc as required at site.in the pac no.1 & sac 62 carrying out wet servicing of existing one nowindow / split type ac units upto 2.0tr capacitycomplete with completecleaning and washing of indoor and outdoor units , cleaning of filter, checking / inspection of all the electrical components and connections for its tightness, checking of electrical parts for proper functioning, checking out all controls, minor rectification of damaged indoor and out door wiring , providing necessary tape and thimbles, including visit and inspection charges complete in all respect , testing and commissionetc. complete as required at site. 63 supplying and fixing / replacement of following electricalitems, suitable for operation on 230v / 415 v , single phase / three phase , 50hz , ac supply in the existing faulty window ac / split ac units / package ac unitcomplete with installation, making interconnections, testing and commissioning etc.as required at site. ( 1.5 tr window, 1.5 / 2 tr split ac and 3 tr hshf ) ( note: the faulty material / compressorshall be handed over to the agency . the agency shall consider suitable buyback pricewhile quoting for the item ) a ) supplying and fixing ofrunning capacitor 50 mfd 64 repairing of the following faulty components ofexisting split / window type ac units including dismantling , repairing , replacement , reinstallation and labour charges complete in all respect for the same, making interconnection, testing and commissioning etc as reqd at site. 65 rewinding of condenser fan motor of 1.5 / 2 tr split ac 66 sh v: fire detection system & fire extinguishers 67 repairing offollowing zone , existing fire detection control panel i / c cleaning , repairing of zonal cards, mother board, control card, charging system, replacement of the faulty / burnt diodes, integrated circuits, leds and power supply unit etc. complete with testing as required. 68 10 zones main control panel. 69 4 zones local control panel. 70 6 zones local control panel. 71 supplying, installation, testing & commissioning of following type fire detectors and other accessories in the existing fire detection and alarm system completewith all connections etc. as required. 72 smoke detector with built in led and mounting base complete. 73 dual chamber heat detector ( heat cum rate of rise in temperature type ) . 74 responseindicator on surface / recess ms box having two leds and metallic cover complete.. 75 manual call point ( pill box ) of ms construction with stainless steel chain and hammer assembly. 76 fire alarm sounder with facility to make announcement mounted in ms box ( 16 swg ) with hinged cover plate. 77 cleaning of the entire existing detectors installed in the bldg. i / c testing etc. complete as required. 78 refilling / recharging of the following type / capacity fire extinguishers as per bis 2190:2010 specifications including repair of fire extinguishers and replacement of defective spare parts like nozzle, safety clip, horn, water, rings, washer, plunger etc. as required and collection, transportation and delivery charges from various exchanges to refilling station and vice versa etc. complete as required: 79 4.5 kg. portable co2 type fire extinguisher....

General Administration Department - Madhya Pradesh

40384392 bids are invited for supply installation testing and commissioning of fps system for dccb morena common control panel with indications , jockey pump set 03 phase required 70 m head , main fire fighting pump set 03 phase required , diesel driven pump set of required 70m head , 150 mm , 100 mm , 80 mm , 50 mm , 25 mm , pressure switch , pressure gauge , butterfly valve , dual plate check valve wafer , two way fire brigade inlet , swinging compact type first aid hose reel , valve with ss ball , valve brass forged , 150 mm , 100 mm flow switch , air release valve , spring type pressure release valve , powder coated double door hose box size , single way landing valve , coupling with gi wire , short branch pipe 63 mm dia , pendent type automatic sprinkler 680 centigrade , hooter , addressable input output mode , hydraulically operated sprinkler alarm unit , armored cable , cooper flexible cable , automatic dual led smoke detector , automatic dual led heat detector , 2 loop micro processor based intelligent , indoor addressable manual break glass unit , indoor stand alone loop powered detector , safety signage , ms air vessel fabricated , first aid fire extinguisher 6kg , first aid fire extinguisher , mechanical foam , core cutting charges , structural steel total quantity : 2739...

General Administration Department - Madhya Pradesh

39910593 bids are invited for supply installation testing and commissioning of bcfa system for dccb morena galaxy 4 zone 4016 gsm control panel , battery , panic switch , magnetic contact 4 wire , heavy duty shutter contact , sounder 12v , internal sounder , quad p.i.r. motion sensor , multi function detector , photoelectric smoke detector , rate of rise heat detector , manual call point , response indicator , cable , installation charges total quantity : 4408...

National Fertilizers Limited - Madhya Pradesh

37351993 annual rate cotract for misc instrument maintenance jobs for the year 2023 24. 1 level measuring instruments 2 removing of level gauges ( pr. rating < 40 kg / cm2 ) 3 fixing of level gauges ( pr. rating < 40 kg / cm2 ) 4 removing of level gauges ( pr. rating > 40 kg / cm2 ) 5 fixing of level gauges ( pr. rating > 40 kg / cm2 ) 6 removing of level switches ( pr. rating < 40 kg / cm2 ) 7 fixing of level switches ( pr. rating < 40 kg / cm2 ) 8 removing of level switches ( pr. rating > 40 kg / cm2 ) 9 fixing of level switches ( pr. rating > 40 kg / cm2 ) 10 removing oflevel troll ( pr. rating < 40 kg / cm2 ) 11 fixing oflevel troll ( pr. rating < 40 kg / cm2 ) 12 removing oflevel ttroll ( pr. rating > 40 kg / cm2 ) 13 fixing oflevel troll ( pr. rating > 40 kg / cm2 ) 14 removing of level controller ( local ) / transmitter 15 fixing of level controller ( local ) / transmitter 16 removing of level transmitters ( purge type ) 17 fixing of level transmitters ( purge type ) 18 removing of level dp transmitter with / without capillary 19 fixing of level dp transmitter with / without capillary 20 removing of ultrasonic / radar / capacitance type level transmitter with accessories 21 fixing of ultrasonic / radar / capacitance type level transmitter with accessories 22 level gauge module removal ( on line ) for high pressure gauges 23 level gauge module fixation ( on line ) for high pressure gauges 24 removal of electrode of hydrastep ( l.g ) 25 fixation of electrode of hydrastep ( l.g ) 26 assistance in removal of nuclear type level instt. 27 assistance in fixing of nuclear type level instt. 28 removal of local float & rope type indicaters 29 fixation of local float & rope type indicaters 30 removal & cleaning of purge tube / dip tube of level transmitter 31 fixation of purge tube / dip tube after cleaning 32 changing of gauge glass / mica sheet / gaskets of lgs 33 pressure measuring instruments 34 removing of pressure gauges ( ordinary ) ( all sizes & ratings ) 35 fixing of pressure gauges ( ordinary ) ( all sizes & ratings ) 36 removing of seal diaphram pressure gauges ( without capillary ) ( all sizes & ratings ) 37 fixation of seal diaphram pressure gauges ( without capillary ) ( all sizes & ratings ) 38 removing of seal diaphram pressure gauges ( with capillary ) ( all sizes & ratings ) 39 fixation of seal diaphram pressure gauges ( with capillary ) ( all sizes & ratings ) 40 removing of pressure switches all types / sizes 41 fixing of pressure switches all types / sizes 42 removing of electronic / pneumatic pressure transmitters ( without capillary ) ( all sizes & ratings ) 43 fixing of electronic / pneumatic pressure transmitters ( without capillary ) ( all sizes & ratings ) 44 removing of electronic / pneumatic pressure transmitter / diff. pressure transmitter ( with capillary ) ( all sizes & ratings ) 45 fixing of electronic / pneumatic pressure transmitter / diff. pressure transmitter ( with capillary ) ( all sizes & ratings ) 46 removing of pr.controller ( electronic ) ( local panel mounted ) 47 fixing of pr.controller ( electronic ) ( local panel mounted ) 48 removing of air pr. regulators any size / rating 49 fixingof air pr. regulators any size / rating 50 removing of pressure transmitter ( lens gasket ) ( electronic / pneumatic ) with capillary 51 fixing of pressure transmitter ( lens gasket ) ( electronic / pneumatic ) with capillary 52 level measuring instruments 53 removing of purge / on line rotameters of all sizes / ratings 54 fixing of purge / on line rotameters of all sizes / ratings 55 removing of dp type flowmeter electronic / pneumatic ( without seal ) 56 fixing of dp type flowmeter electronic / pneumatic ( without seal ) 57 removing of dp type flowmeter electronic / pneumatic ( with seal ) 58 fixing of dp type flowmeter electronic / pneumatic ( with seal ) 59 removal of turbine flowmeter 60 fixingof turbine flowmeter 61 removal of electro magnetic type flowmeter 62 fixingof electro magnetic type flowmeter 63 removing of dpi / dp type local flowmeter 64 fixing of dpi / dp type local flowmeter 65 removing of pitot tube / annubar of any size / rating 66 fixing of pitot tube / annubar of any size / rating 67 removing of flow switches for line size upto 2 68 fixing of flow switches for line size upto 2 69 removing of flow switches for line size > 2 70 fixing of flow switches for line size > 2 71 temperature measuring instruments 72 removing of the thermo couple / rtd elements ( single, duplex, triplex ) including elecrical termination 73 fixing of the thermo couple / rtd elements ( single, duplex, triplex ) including electrical termination 74 removing of the temperature recorder / indicator / monitor from panel 75 fixing of the temperature recorder / indicator / monitor from panel 76 removing of local temperature gauge ( bimettalic / filled ) with mounting 77 fixing of local temperature gauge ( bimettalic / filled ) with mounting 78 removing of temperature switch including electrical termination 79 fixing of temperature switch including electrical termination 80 removing of capillary filled type local temperature gauge with mounting 81 fixing of capillary filled type local temperature gauge with mounting 82 removal of thermowell of all sizes & ratings 83 fixingof thermowell of all sizes & ratings 84 analysers 85 removing and cleaning of water analysers ( ph, conductivity, residual chlorine ) including asssociated accessories 86 fixing back of water analysers ( ph, conductivity, residual chlorine ) including asssociated accessories 87 removing and cleaning of the gas analysers ( co, co2, methane, nh3, o2, h2, etc. ) including accessories 88 fixing of the gas analysers ( co, co2, methane, nh3, o2, h2, etc. ) including accessories 89 removal and cleaning of chlorine detectors including accessories 90 fixing of chlorine analyser detectors including accessories 91 removal and cleaning of chlorine ejector 92 fixing of chlorine ejector 93 removal and cleaning of chlorine regulator 94 fixing of chlorine regulator 95 removing, cleaning & tightening of water analyser sampling system components 96 removing and cleaning of ph analyser filters & fixing them back 97 removing of calibration gas cylinders with regulators & connections 98 fixing of calibration gas cylinders with regulators & connections 99 removing of gas regulators from gas cylinders 100 fixing of gas regulators from gas cylinders 101 removal of damaged sample cooling coil, repair / fabrication of new coil from 6mm ss tube & mounting of same in sample cooler 102 impulse line piping for transmitters 103 laying, fabrication, erection & testing including required cutting, fitting & welding jobs for following pipe size / rating: 104 size 1 / 2 carbon steel, non ibr sch 40 105 size 1 / 2 carbon steel, non ibr sch 80 106 size 1 / 2 carbon steel, non ibr sch 160 107 size 1 / 2 stainless steel, non ibr sch 40 / 80 108 size 1 / 2 stainless steel, non ibr sch 160 109 size 1 / 2 alloy steel, non ibr sch 40 110 size 1 / 2 alloy steel, non ibr sch 80 111 size 1 / 2 alloy steel, non ibr sch 160 112 size 1 / 2 alloy steel, ibr sch 40 113 size 1 / 2 alloy steel, ibr sch 80 114 size 1 / 2 alloy steel, ibr sch 160 115 size 1 carbon steel, non ibr sch 40 / 80 116 size 1 stainless steel, non ibr sch 40 / 80 117 size 2 carbon steel, non ibr sch 40 / 80 118 size 2 stainless steel, non ibr sch 40 / 80 119 removal of pipingwith supports including cutting for all sizes irrespective of pipe material & rating 120 laying & testing of gi pipe including cutting, fitting & welding jobs for following pipe sizes: 121 size 1 / 2 122 size 1 123 size 2 124 removal of gi pipe with supports including cutting for all sizes 125 arrest the leakage of a joint by welding / rewelding of joint / welding of crack or broken parts 126 for carbon steel material & all rating 127 for stainless steel material & all rating 128 removal of condensate pots including related cutting 129 fixing of condensate pots including cutting & welding 130 fabrication & installation of float guide upto 4 pipe 131 tubing jobs ( including connections & testing ) 132 size 6mm s.s. / copper tube laying 133 size 6mm s.s. / copper tube removing 134 size 8mm s.s. / copper tube laying 135 size 8mm s.s. / copper tube removing 136 size 10mm s.s. / copper tube laying 137 size 10mm s.s. / copper tube removing 138 size 12mm s.s. / copper tube laying 139 size 12mm s.s. / copper tube removing 140 cabling jobs: cable laying on cable tray / trench / conduits, glanding, termination & checking of cables for loop continuity. removing of cables from cable trays / trench / conduits including electrical terminations and storing them with proper marking. cable types: signal, power, control, thermocouple, rtd cables conductor size =<0.5mm2 ( armoured / unarmoured ) , optical fiber cable for cctv. 141 laying of cable, 2 core to 6 core 142 removing of cable, 2 core to 6 core 143 laying of cable, 7 core to 24 core 144 removing of cable 7 core to 24 core 145 fixing of junction box complete with accessories ( area<=500 cm2 ) 146 removal of junction box disconnecting electrical cables ( area<=500 cm2 ) 147 fixing of junction box complete with accessories ( area>500 cm2 ) 148 removal of junction box disconnecting electrical cables ( area>500 cm2 ) 149 digging 300mm wide 0.5 m deep trench, laying of bricks & filling back with sand / earth after laying the cable 150 laying conduit / gi pipe=<2through the trench 300mmwide 0.5m deep 151 dressing of the cables ( 2 to 24 core ) with proper clamping 152 removal of broken bolts of jb covers & fixing new bolts. 153 replacement of cable gland / pipe fitting / tube fitting, where cable laying / pipe laying / tube laying is not desired. size upto 2 and all rating & material. 154 laying of optical fiber cable 155 removing of optical fiber cable 156 crimping / splicing of optical fiber cable pieces 157 tray & other misc. jobs tray / angle iron laying ( for tubing / cables ) fixing of supports including related cutting, welding, fitting jobs for different sizes: 158 size : 2 / 50 mm wide 159 size : 4 / 100 mm wide 160 size : 8 / 200 mm wide 161 size : 16 / 400 mm wide 162 al. tray cover fixation size 200 mm. 163 al. tray cover fixation size 400 mm. 164 tray / angle iron removing ( for tubing / cables ) including related cutting & grindingjobs for different sizes: 165 size : 2 / 50 mm wide 166 size : 4 / 100 mm wide 167 size : 8 / 200 mm wide 168 size : 16 / 400 mm wide 169 al. tray cover removal size 200 mm. 170 al. tray cover removal size 400 mm. 171 fabrication / re conditioning & erection of gi / ms sheet canopies / protection covers for transmitters / other instruments of size upto 1 sq m. area 172 fabrication of supports of structural steel 173 fabrication of stanchions for mounting insts. as per standards 174 dismentling of structure by opening bolts, gas cutting, removal & shifting from site to scrap stores 175 removing of canopy / protection cover for maintenance job of instrument and fixing back ( any size ) 176 isolation valves & gland packing jobs fixing of isolation valves ( socket weld / threaded type ) including fitting, welding & pressure testing job for following sizes : 177 size 1 / 4, upto 1500# lbs rating cs / ss 178 size 1 / 2, 1500# 3000# lbs rating cs / ss 179 size 1, 1500# 3000# lbs rating cs / ss 180 size 2, 1500# 3000# lbs rating cs / ss 181 removal of isolation valves ( socket weld / threaded type ) including fitting, cutting job irrespective of material, rating & upto size 2 inclusive 182 gland packing of isolation valves / control valves of any sizes 183 opening of flanges, cleaning, repair & polishing of gasket surfaces ( including lapping of ring / lens joint type ) and boxing up as & when required. size upto 4 and all ratings 184 dismentaling, cleaning and assembling of condensate drain system in passivation air comprs. ( k 3 ) 185 control valve jobs 186 opening of control valve from actuator / bonnet / line upto 2 size & any rating 187 opening of control valve from actuator / bonnet / line upto 3 size & any rating 188 opening of control valve from actuator / bonnet upto 4 size & any rating 189 opening of control valve from actuator / bonnet upto 5 & 6 size & any rating 190 opening of control valve from actuator / bonnet upto 8 & 10 size & any rating 191 opening of control valve from actuator / bonnet above 10 size & any rating 192 fixing back of control valve actuator / bonnet on the body / line upto 2 size & any rating 193 fixing back of control valve actuator / bonnet on the body / line upto 3 size & any rating 194 fixing back of control valve actuator / bonnet on the body upto 4 size & any rating 195 fixing back of control valve actuator / bonnet on the body upto 5 & 6 size & any rating 196 fixing back of control valve actuator / bonnet on the body upto 8& 10 size & any rating 197 fixing back of control valve actuator / bonnet on the body above 10 any rating 198 removal of valve positioner with its pneumatic / electrical connection 199 removal of pilot relay / lockup relay, limitswitch alongwith pneumatic / electrical connection 200 removal of volume booster alongwith its pneumatic connection 201 removal of i / p convertor alongwith pneumatic / electrical connection 202 removal of solenoid valve alongwith pneumatic / electrical connection 203 fixing of valve positioner alongwith pneumatic / electrical connection 204 fixing of pilot relay / lockup relay, limitswitch alongwith pneumatic / electrical connection 205 fixing of volume booster alongwith its pneumatic connection 206 fixing of i / p convertor alongwith its pneumatic / electrical connection 207 fixing of solenoid valve alongwith pneumatic / electrical connection 208 replacement of actutor diapragm ( pneumatic ) of any size actuator 209 removal of piston / power cylinder alongwith pneumatic connection 210 fixing of piston / power cylinder alongwith pneumatic connection 211 lapping of plug , seat & other sealing surface of control valves 212 greasing of control valve parts 213 removal of air filter regulator set with fittings 214 fixingof air filter regulator set with fittings 215 jobs in bagging plant area 216 removal and cleaning of level probes & refixing 217 cleaning of machines, weigh pans, solenoid valves, power cylinders etc. 218 replacement of broken weigh pan assembly of bagging machines & repairing by doing necessary cutting / welding, cleaning etc. 219 cleaning of avery / tulaman pre determined weighing scales ( check weighers ) 220 cleaning of et 6 belt weighers framework and related equipments 221 assistance in calibration of bagging machines by putting weights 222 fixing of power cylinder of piston dia.upto 100mm on the machine 223 removing of power cylinder of piston dia.upto 100mm from machine 224 removal of solenoid valve spool type 5 ports 225 fixing of solenoid valve spool type 5 ports 226 laying / removing pvc / nylon tubing upto 12mm size 227 filling of oil in bagging machine air regulators 228 replacement of proximity sensor in pandoor / bagholder of bagging machines 229 replacement & repairing of broken feed gate assembly of bagging machines by doing necessary cutting / welding, cleaning etc. 230 removing, cleaning & fixing of anti vibration pads in bagging machines 231 replacement & repairing of brokenbag holder assembly of bagging machines by doing necessary cutting / welding, cleaning etc. 232 replacement of load cell ( including all accessories ) of urea bunker level measuring system / urea belt weigher / weigh bridges 233 other misc.jobs 234 removing of manual call points mcp ) including accessories 235 refixing of manual call points mcp ) including glanding and termination 236 removing of heat, flame or smoke detectors & termination 237 refixing of heat, flame or smoke detectors & termination 238 painting of control valves, actuators including accessories & other insts. with mounting stand 239 writing of tag nos. on instruments, control valves, etc 240 cleaning of instruments, control valves, local panels, ccr cabinets etc 241 laying of heat detector cable on cable trays & their connections 242 removing of heat detector cable on cable trays 243 removal of speed / vibration / axial displacement probe / extension cable 244 fixation of speed / vibration / axial displacement probe / extension cable 245 removal of field tachometer / speed indicator 246 fixation of field tachometer / speed indicator 247 control panel cutting ( for cable entry or providing new instrument ) 248 removal of low explosive limit detector / ammonia detector / co detector 249 fixation of low explosive limit detector / ammonia detector / co detector 250 transportation of instruments / materials from respective plant to instrument workshop / store 251 transportation of instruments / materials from instrument workshop / store to respective plants 252 removal of uv flame scanner & cleaning 253 fixation of uv flame scanner 254 removal of weephole probe in urea reactors 255 fixing of weephole probe in urea reactors 256 removal, cleaning / washing and fixing of suction air filters of ccr / lcr control cabinets ( dcs / esd / ops / his / vms & printer consoles ) 257 panel cooling fans removing, cleaning & checking 258 panel cooling fans fixing ( including mounting arrangement ) 259 various plant jobs: to assist nfl employees in executing various instrument maintenance jobs in routine day to day maintenance in general shift, central shift. ( 8 hrs of normal working ) mandays for sr no 14.01 14.02, 1. bidder has to ensure due diligence to comply with statutory obligations as nit clause of stc ( annexure xiv ) 2. price bids will be rejected if the quoted rate is found less than the notified minimum wages for unskilled / skilled workers applicable as on 01.04.2023 plus statutory obligation @ 32.91%of the applicable minimum wages as on 01.04.2023 to comply statutory obligations. reference calculation for item s.no 14 ( 14.01 14.02 ) are as under: ( minimum 32.91% ) ( 8 hrs of normal working ) ( 1 ) minimum wages for helper ( unskilled ) = 494 + 162.58= 656.58 ( 2 ) minimum wages for skilled manpower =695 + 228.72=923.72quoted rateshall not be less than minimum amount as mentioned above. 260 helper ( un skilled ) 261 manpower ( skilled ) 262 ot hours : to assist nfl employees in executing various instrument maintenance jobs during unforeseen breakdown / short shutdown & emergency requirement. ( beyond 8 hrs of normal working ) .refernce calculation included esi @3.25% on minimum wage as on 01.04.2023 for items under s.no 15 & 17 are as under: ( 1 ) minimum wages for helper ( unskilled ) = ( 494+16.06 ( esic ) / 8 ) *2= 127.51. ( 2 ) minimum wages for skilled manpower = ( 695+22.59 ( esic ) / 8 ) *2= 179.40.party shall be paid above fixed rate without any service charge as per clause 1 ( ii ) of stc & tc annexure xiv. 263 helper ( un skilled ) 264 manpower ( skilled ) 265 planned shutdown: supply of contract labour for planned shutdown of line i & line ii. ( 8 hrs of normal working ) mandays for sr no 16.01 16.06, 1. bidder has to ensure due diligence to comply with statutory obligations as per nit clause of stc ( annexure xiv ) .2. price bids will be rejected if the quoted rate is found less than the notified minimum wages for unskilled / skilled workers applicable as on 01.04.2023 plus statutory obligation @ 16.25% of the applicable minimum wages as on 01.04.2023 to comply statutory obligations. refernce calculation for item s.no 16 ( 16.01 to 16.06 ) are as under: ( minimum 16.25% ) ( 8 hrs of normal working ) ( 1 ) minimum wages for helper ( unskilled ) = 494 + 80.28 = 574.28. ( 2 ) minimum wages for skilled manpower =695 +112.94 = 807.94.quoted rateshall not be less than minimum amount as mentioned above. 266 helper ( un skilled ) 267 fitter ( skilled ) 268 rigger ( skilled ) 269 welder ( skilled ) 270 electrician ( skilled ) 271 technician ( skilled ) 272 ot hours : supply of contract labour for planned shutdown of line i & line ii. ( beyond 8 hrs of work ) . party shall be paid fixed rate without any service charge as mentioned at sl. no. 15 above as per clause 1 ( ii ) of stc & tc annexure xiv. 273 helper ( un skilled ) 274 fitter ( skilled ) 275 rigger ( skilled ) 276 welder ( skilled ) 277 electrician ( skilled ) 278 technician ( skilled ) ...

Department of Higher Education - Madhya Pradesh

36520730 bids are invited for microprocessor based addressable fire alarm system fire alarm pamel , smoke detector , heat detector , mcp , sounder , safety device , monitor module , control module , armured cable total quantity : 2397...

Ministry Of Petroleum And Natural Gas - Madhya Pradesh

36022562 bids are invited for operated siren mse smoke and heat detector test kit , flameproof illuminated wind socks , portable siren hand operated and floor mounted with minimum range of 1.5 kilometre smoke and heat detector kit wind socks and hand total quantity : 16...

National Handloom Development Corporation Limited - Madhya Pradesh

33305073 procurement of spares for fire fighting system installed at power house of omkareshwar power station procurement of spares for fire fighting system installed at power house of omkareshwar power station , linear heat sensing cable , quartzoid bulb heat detector , high velocity water spray nozzle type b, k 18, 3 / 8” bsp connection. material: brass , medium velocity spray nozzle ½” bsp connection, spray angle: 80 degree, k 22, material: brass ( nickel chrome plated ) , solenoid valve ½” bspfemale screwed end on both side, valve position normally close, media water, single phase ac, moc brass , pressure switch: range 1 to 10 kg / cm2, contact differential 0.3 to 1.3 kg / cm2, contact 2no+2nc, supply voltage 250 vac, connection 3 / 8” bsp ( male ) bottom, sensing ss304 seamless bellow; compatible to rt116 ( sb ) , note: 1 ) transit insurance shall be in the scope of nhdc ltd. 2 ) bidder should quote unit basic rate inclusive of packing, forwarding, handling and freight charges for f.o.r. omkareshwar power station in column no.5. 3 ) bidder shall quote unit cgst, sgst amount in column no. 6 &7 respectively for intra state supply or shall quote igst amount in column no. 8 for inter state supply. 4 ) bidders are requested to verify carefully the amount entered by them in respective column and the amount generated automaticallythrough formulae before uploading it to the portal...

National Handloom Development Corporation Limited - Madhya Pradesh

33179941 procurement of spares for fire fighting system installed at power house of omkareshwar power station procurement of spares for fire fighting system installed at power house of omkareshwar power station , linear heat sensing cable , quartzoid bulb heat detector , high velocity water spray nozzle type b, k 18, 3 / 8” bsp connection. material: brass , medium velocity spray nozzle ½” bsp connection, spray angle: 80 degree, k 22, material: brass ( nickel chrome plated ) , solenoid valve ½” bspfemale screwed end on both side, valve position normally close, media water, single phase ac, moc brass , pressure switch: range 1 to 10 kg / cm2, contact differential 0.3 to 1.3 kg / cm2, contact 2no+2nc, supply voltage 250 vac, connection 3 / 8” bsp ( male ) bottom, sensing ss304 seamless bellow; compatible to rt116 ( sb ) , note: 1 ) transit insurance shall be in the scope of nhdc ltd. 2 ) bidder should quote unit basic rate inclusive of packing, forwarding, handling and freight charges for f.o.r. omkareshwar power station in column no.5. 3 ) bidder shall quote unit cgst, sgst amount in column no. 6 &7 respectively for intra state supply or shall quote igst amount in column no. 8 for inter state supply. 4 ) bidders are requested to verify carefully the amount entered by them in respective column and the amount generated automaticallythrough formulae before uploading it to the portal...

Gas Authority Of India Limited - Madhya Pradesh

32783655 procurement of smoke and heat detector procurement of smoke and heat detector combo testing kit with standard accessories through nic portal , detector test kit for smoke and heat with universal removal tool ( for further details refer section v: technical specification of the tender document ) addl description: specification for smoke and heat detector test kit 1. the kit should be capable of testing smoke and heat detector at a height and at below floor level also. one kit to be used for both smoke and heat detectors. the option for detector to be tested i.e. smoke or heat should be selectable from a digital keypad with display. 2. detector kit should be suitable for use on smoke and heat detectors of both conventional and addressable types. 3. the kit should include a universal detector removal tool which is capable of removing all types of generally available smoke detectors. the detector removal tool should be easy to mount on extension pole to reach approx. 9 meters of height. it should be adjustable to cater to different diameters of detectors. 4. extension pole should be adjustable and should reach around 9 meters height. pole will be of light weight but good quality fiber material to bear the load of detectors testing kit. 5. a dispenser should be there to hold the smoke detector tester on the extension head in such a way that spray should not disperse out of dispenser. it should be easy to mount and easy to disassemble. 6. dispenser should be clear cup transparent type which allows the view of detector led. 7. smoke detector tester should be non flammable, nontoxic, and environment friendly. 8. it should be oil; free formulation and there should be no lasting residue 9. it must be ul certified. 10. since it is an important item, party must provide spares & service to gail india ltd. as per our requirement. 11. the kit should be supplied with standard accessories like smoke capsules, battery batons and chargers , adjustable extension poles for reaching detectors at approx. 9 meters height, carry and storage bag for both accessories and extension poles etc. the following item (includes smoke/heat/co kit are) to be supplied 01. smoke detector testing kit should have # solo fiber glass 2 section telescopic pole 4.5 meter 01 nos # solo 200 001 detector removal (universal detector removal) 01nos # solo 330 001 aerosol smoke & co dispenser 01 nos 02. heat detector test kit (solo 461 101 cordless) o1 set should have # 1xsols 460 001cordless heat head unit 01 # 2xsolo 760 001 battery baton 01 # 1x solo 725 001 fast charger 01 03. aerosals should have # solo a3 001 detector tester 250ml 06 nos # solo c3 001 co testing for co fire detector 06 nos # solo a7 001 clearing smoke detector 06nos 04. protective carrying / storage bag: 01no....

National Handloom Development Corporation Limited - Madhya Pradesh

32761147 procurement of spares for fire fighting system installed at power house of omkareshwar power station procurement of spares for fire fighting system installed at power house of omkareshwar power station , linear heat sensing cable , quartzoid bulb heat detector , high velocity water spray nozzle type b, k 18, 3 / 8” bsp connection. material: brass , medium velocity spray nozzle ½” bsp connection, spray angle: 80 degree, k 22, material: brass ( nickel chrome plated ) , solenoid valve ½” bspfemale screwed end on both side, valve position normally close, media water, single phase ac, moc brass , pressure switch: range 1 to 10 kg / cm2, contact differential 0.3 to 1.3 kg / cm2, contact 2no+2nc, supply voltage 250 vac, connection 3 / 8” bsp ( male ) bottom, sensing ss304 seamless bellow; compatible to rt116 ( sb ) , note: 1 ) transit insurance shall be in the scope of nhdc ltd. 2 ) bidder should quote unit basic rate inclusive of packing, forwarding, handling and freight charges for f.o.r. omkareshwar power station in column no.5. 3 ) bidder shall quote unit cgst, sgst amount in column no. 6 &7 respectively for intra state supply or shall quote igst amount in column no. 8 for inter state supply. 4 ) bidders are requested to verify carefully the amount entered by them in respective column and the amount generated automaticallythrough formulae before uploading it to the portal...

National Handloom Development Corporation Limited - Madhya Pradesh

31695527 procurement of spares for fire fighting system installed at power house of omkareshwar power station procurement of spares for fire fighting system installed at power house of omkareshwar power station , linear heat sensing cable , quartzoid bulb heat detector , high velocity water spray nozzle type b, k 18, 3 / 8” bsp connection. material: brass , medium velocity spray nozzle ½” bsp connection, spray angle: 80 degree, k 22, material: brass ( nickel chrome plated ) , solenoid valve ½” bspfemale screwed end on both side, valve position normally close, media water, single phase ac, moc brass , pressure switch: range 1 to 10 kg / cm2, contact differential 0.3 to 1.3 kg / cm2, contact 2no+2nc, supply voltage 250 vac, connection 3 / 8” bsp ( male ) bottom, sensing ss304 seamless bellow; compatible to rt116 ( sb ) , note: 1 ) transit insurance shall be in the scope of nhdc ltd. 2 ) bidder should quote unit basic rate inclusive of packing, forwarding, handling and freight charges for f.o.r. omkareshwar power station in column no.5. 3 ) bidder shall quote unit cgst, sgst amount in column no. 6 &7 respectively for intra state supply or shall quote igst amount in column no. 8 for inter state supply. 4 ) bidders are requested to verify carefully the amount entered by them in respective column and the amount generated automaticallythrough formulae before uploading it to the portal...

Madhya Pradesh Power Generating Company Limited - Madhya Pradesh

31625320 procurement of c andi spares for carrier fire and security ( edwards est 3 fire fighting system ) make fire fighting system of 2x600 mw of sstpp, dongalia, khandwa procurement of c andi spares for carrier fire and security ( edwards est 3 fire fighting system ) make fire fighting system of 2x600 mw of sstpp, dongalia, khandwa , est3 power supply ( 3 pps / m 230 ) , power supply for edward make panel, hsn / sac code: 85311090 , est3 960 character lcd display ( 3 lcdxl1 ) , display board for edward make panel, hsn / sac code: 85311090 , est3 rs232 card ( 3 rs232 ) , rs 232 card for edward make panel, hsn / sac code: 85311090 , est3 dual loop card ( 3 sddc1 ) , dual loop card for edward make panel, hsn / sac code: 85311090 , est3 fiber optic interface module 3 fibmb2, fiber optic network card for edward make panel, hsn / sac code: 8531 , est3 fiber ( smxlo2 ) , communication module for edward make panel one panel need two nos incase both end is in fiber connectivity, hsn / sac code: 8531 , est optica multi detector siga ohsd, hsn / sac code: 8531. , est optica smoke detector siga osd, hsn / sac code: 8531. , est isolator base ( siga ib ) , hsn / sac code: 85311090. , est heat detector ( siga hrd ) , siga hrs is absolute and new model is back to back compatible with old panel hsn / sac code: 85311090 , est monitor module ( siga ct1 ) , hsn / sac code: 85311090. , est control module ( siga cr ) , hsn / sac code: 85311090. , est3 control relay module ( siga cc1 ) , hsn / sac code: 85311090 , est manual call point ( siga 278 ) , sigi271 is not ul & fm listed product so we have quoted dual stage which is higher specks and resettable through key, hsn / sac code: 85311090. , est hooter cum strobe ( g1avrf ) , quoted edward make ul / fm listed product led strobe, hsn / sac code: 85311090. , edward probe type detector 302 epm 135 ( ul / fm listed ) hsn / sac code: 8531 , flameproof junction box for probe type heat detector and module installation, hsn / sac code: 8535 , flameproof gland double compressor gland, hsn / sac code: 7318. , est weather proof manual call point ( mpsr2 s45w ) ( ul / fm listed ) , hsn / sac code: 85311090 , est standard base ( siga sb ) hsn / sac code: 85311090 , response indicator, hsn / sac code: 8535....

Madhya Pradesh Power Generating Company Limited - Madhya Pradesh

30490985 design, supply, erection, testing and commissioning of co2 gas flooding system for hydro generator protection system including supply of material required for renovation of co2 gas flooding system at 3x20 mw bhps iii deolond. design, supply, erection, testing and commissioning of co2 gas flooding system for hydro generator protection system including supply of material required for renovation of co2 gas flooding system at 3x20 mw bhps iii deolond. , painting of the co2 system with two coat of post office enamel red paint over one coat of red oxide primer etc complete in all respect. , seamless cylinders, ccoe approved capacity 36 kg complete in all respect of any existing cylinder failed in tests ( on actual basis) , refilling of co2 gas with 99.9% purity, each cylinder gas capacity 36 kg. , co2 cylinder bank along with weighing device mounting rail (suitable for 9 nos. of 36 kg capacity co2 cylinders) & accessories like seamless header, nut bolts, rubber gaskets etc. , master valve with solenoid & manual lever , slave valve with pneumatic actuator & manual lever , non return valve suitable for fixing at co2 discharge header , high pressure discharge hose , high pressure pneumatic actuation hose , pilot cylinder 3.0 ltr. water capacity filled with 2.0 kg n2 gas fitted with solenoid valve with manual lever to operate directional valve. , 32 nb co2 directional valve with pneumatic actuator & limit switch , 25 nb co2 directional valve with pneumatic actuator & limit switch , continuous gas monitor – led type , continuous gas weight monitor control panel suitable to connect 09 nos. of gas weight monitor common for all type of weight monitors. , manifold safety valve , pressure switch , discharge warning display unit , inhibit / abort switch , manual gas release , electronic dual tone hooter with flashing lamp for indoor application , m s seamless pipe sch 80 with all required tee, reducers, flanges, gaskets, nut bolts, etc as required. size 32 nb , m s seamless pipe sch 80 with all required tee, reducers, flanges, gaskets, nut bolts, etc as required. size 25 nb , 2 c x 1.5 sqmm copper armoured frls fire survival cable including all consumables , conventional fire detection & alarm panel with gas release modules working on 6 zone with 02 nos. spare , smoke detector/ probe type fixed temperature heat detector with junction , high pressure discharge nozzle with bowl , hydro test of seamless cylinders , installation, testing & commissioning of system...

National Fertilizers Limited - Madhya Pradesh

30206468 annual rate contract of misc. instrumentation maintenance jobs at nfl vijaipur unit for the year 2021 22 ( a ) removing of level gauges ( pr. rating < 40 kg / cm2 ) 3 fixing of level gauges ( pr. rating < 40 kg / cm2 ) 4 removing of level gauges ( pr. rating > 40 kg / cm2 ) 5 fixing of level gauges ( pr. rating > 40 kg / cm2 ) 6 removing of level switches ( pr. rating < 40 kg / cm2 ) 7 fixing of level switches ( pr. rating < 40 kg / cm2 ) 8 removing of level switches ( pr. rating > 40 kg / cm2 ) 9 fixing of level switches ( pr. rating > 40 kg / cm2 ) 10 removing oflevel troll ( pr. rating < 40 kg / cm2 ) 11 fixing oflevel troll ( pr. rating < 40 kg / cm2 ) 12 removing oflevel ttroll ( pr. rating > 40 kg / cm2 ) 13 fixing oflevel troll ( pr. rating > 40 kg / cm2 ) 14 removing of level controller ( local ) / transmitter 15 fixing of level controller ( local ) / transmitter 16 removing of level transmitters ( purge type ) 17 fixing of level transmitters ( purge type ) 18 removing of level dp transmitter with / without capillary 19 fixing of level dp transmitter with / without capillary 20 removing of ultrasonic / radar / capacitance type level transmitter with accessories 21 fixing of ultrasonic / radar / capacitance type level transmitter with accessories 22 level gauge module removal ( on line ) for high pressure gauges 23 level gauge module fixation ( on line ) for high pressure gauges 24 removal of electrode of hydrastep ( l.g ) 25 fixation of electrode of hydrastep ( l.g ) 26 assistance in removal of nuclear type level instt. 27 assistance in fixing of nuclear type level instt. 28 removal of local float & rope type indicaters 29 fixation of local float & rope type indicaters 30 removal & cleaning of purge tube / dip tube of level transmitter 31 fixation of purge tube / dip tube after cleaning 32 changing of gauge glass / mica sheet / gaskets of lgs 33 pressure measuring instruments 34 removing of pressure gauges ( ordinary ) ( all sizes & ratings ) 35 fixing of pressure gauges ( ordinary ) ( all sizes & ratings ) 36 removing of seal diaphram pressure gauges ( without capillary ) ( all sizes & ratings ) 37 fixation of seal diaphram pressure gauges ( without capillary ) ( all sizes & ratings ) 38 removing of seal diaphram pressure gauges ( with capillary ) ( all sizes & ratings ) 39 fixation of seal diaphram pressure gauges ( with capillary ) ( all sizes & ratings ) 40 removing of pressure switches all types / sizes 41 fixing of pressure switches all types / sizes 42 removing of electronic / pneumatic pressure transmitters ( without capillary ) ( all sizes & ratings ) 43 fixing of electronic / pneumatic pressure transmitters ( without capillary ) ( all sizes & ratings ) 44 removing of electronic / pneumatic pressure transmitter / diff. pressure transmitter ( with capillary ) ( all sizes & ratings ) 45 fixing of electronic / pneumatic pressure transmitter / diff. pressure transmitter ( with capillary ) ( all sizes & ratings ) 46 removing of pr.controller ( electronic ) ( local panel mounted ) 47 fixing of pr.controller ( electronic ) ( local panel mounted ) 48 removing of air pr. regulators any size / rating 49 fixingof air pr. regulators any size / rating 50 removing of pressure transmitter ( lens gasket ) ( electronic / pneumatic ) with capillary 51 fixing of pressure transmitter ( lens gasket ) ( electronic / pneumatic ) with capillary 52 flow measuring instruments 53 removing of purge / on line rotameters of all sizes / ratings 54 fixing of purge / on line rotameters of all sizes / ratings 55 removing of dp type flowmeter electronic / pneumatic ( without seal ) 56 fixing of dp type flowmeter electronic / pneumatic ( without seal ) 57 removing of dp type flowmeter electronic / pneumatic ( with seal ) 58 fixing of dp type flowmeter electronic / pneumatic ( with seal ) 59 removal of turbine flowmeter 60 fixingof turbine flowmeter 61 removal of ovalgear type / mass flowmeter 62 fixingof ovalgear type / mass flowmeter 63 removal of electro magnetic type flowmeter 64 fixingof electro magnetic type flowmeter 65 removing of dpi / dp type local flowmeter 66 fixing of dpi / dp type local flowmeter 67 removing of pitot tube / annubar of any size / rating 68 fixing of pitot tube / annubar of any size / rating 69 removing of flow switches for line size upto 2 70 fixing of flow switches for line size upto 2 71 removing of flow switches for line size > 2 72 fixing of flow switches for line size > 2 73 removing of recorder from local / ccr panel 74 fixing of recorder from local / ccr panel 75 temperature measuring instruments 76 removing of the thermo couple / rtd elements ( single, duplex, triplex ) including elecrical termination 77 fixing of the thermo couple / rtd elements ( single, duplex, triplex ) including electrical termination 78 removing of the temperature recorder / indicator / monitor from panel 79 fixing of the temperature recorder / indicator / monitor from panel 80 removing of local temperature gauge ( bimettalic / filled ) with mounting 81 fixing of local temperature gauge ( bimettalic / filled ) with mounting 82 removing of temperature switch including electrical termination 83 fixing of temperature switch including electrical termination 84 removing of capillary filled type local temperature gauge with mounting 85 fixing of capillary filled type local temperature gauge with mounting 86 removal of thermowell of all sizes & ratings 87 fixingof thermowell of all sizes & ratings 88 analysers 89 removing and cleaning of water analysers ( ph, conductivity, residual chlorine ) including asssociated accessories 90 fixing back of water analysers ( ph, conductivity, residual chlorine ) including asssociated accessories 91 removing and cleaning of the gas analysers ( co, co2, methane, nh3, o2, h2, etc. ) including accessories 92 fixing of the gas analysers ( co, co2, methane, nh3, o2, h2, etc. ) including accessories 93 removal and cleaning of chlorine detectors including accessories 94 fixing of chlorine analyser detectors including accessories 95 removal and cleaning of chlorine ejector 96 fixing of chlorine ejector 97 removal and cleaning of chlorine regulator 98 fixing of chlorine regulator 99 removing, cleaning & tightening of water analyser sampling system components 100 removing and cleaning of ph analyser filters & fixing them back 101 removing of calibration gas cylinders with regulators & connections 102 fixing of calibration gas cylinders with regulators & connections 103 removing of gas regulators from gas cylinders 104 fixing of gas regulators from gas cylinders 105 removal of damaged sample cooling coil, repair / fabrication of new coil from 6mm ss tube & mounting of same in sample cooler 106 impulse line piping for transmitters 107 laying, fabrication, erection & testing including required cutting, fitting & welding jobs for following pipe size / rating: 108 size 1 / 2 carbon steel, non ibr sch 40 109 size 1 / 2 carbon steel, non ibr sch 80 110 size 1 / 2 carbon steel, non ibr sch 160 111 size 1 / 2 stainless steel, non ibr sch 40 / 80 112 size 1 / 2 stainless steel, non ibr sch 160 113 size 1 / 2 alloy steel, non ibr sch 40 114 size 1 / 2 alloy steel, non ibr sch 80 115 size 1 / 2 alloy steel, non ibr sch 160 116 size 1 / 2 alloy steel, ibr sch 40 117 size 1 / 2 alloy steel, ibr sch 80 118 size 1 / 2 alloy steel, ibr sch 160 119 size 1 carbon steel, non ibr sch 40 / 80 120 size 1 stainless steel, non ibr sch 40 / 80 121 size 2 carbon steel, non ibr sch 40 / 80 122 size 2 stainless steel, non ibr sch 40 / 80 123 removal of pipingwith supports including cutting for all sizes irrespective of pipe material & rating 124 laying & testing of gi pipe including cutting, fitting & welding jobs for following pipe sizes: 125 size 1 / 2 126 size 1 127 size 2 128 removal of gi pipe with supports including cutting for all sizes 129 arrest the leakage of a joint by welding / rewelding of joint / welding of crack or broken parts 130 for carbon steel material & all rating 131 for stainless steel material & all rating 132 removal of condensate pots including related cutting 133 fixing of condensate pots including cutting & welding 134 fabrication & installation of float guide upto 4 pipe 135 tubing jobs ( including connections & testing ) 136 size 6mm s.s. / copper tube laying 137 size 6mm s.s. / copper tube removing 138 size 8mm s.s. / copper tube laying 139 size 8mm s.s. / copper tube removing 140 size 10mm s.s. / copper tube laying 141 size 10mm s.s. / copper tube removing 142 size 12mm s.s. / copper tube laying 143 size 12mm s.s. / copper tube removing 144 cabling jobs: cable laying on cable tray / trench / conduits, glanding, termination & checking of cables for loop continuity. removing of cables from cable trays / trench / conduits including electrical terminations and storing them with proper marking. cable types: signal, power, control, thermocouple, rtd cables conductor size =<0.5mm2 ( armoured / unarmoured ) 145 laying of cable, 2 core to 6 core 146 removing of cable, 2 core to 6 core 147 laying of cable, 7 core to 24 core 148 removing of cable 7 core to 24 core 149 fixing of junction box complete with accessories ( area<=500 cm2 ) 150 removal of junction box disconnecting electrical cables ( area<=500 cm2 ) 151 fixing of junction box complete with accessories ( area>500 cm2 ) 152 removal of junction box disconnecting electrical cables ( area>500 cm2 ) 153 digging 300mm wide 0.5 m deep trench, laying of bricks & filling back with sand / earth after laying the cable 154 laying conduit / gi pipe=<2through the trench 300mmwide 0.5m deep 155 dressing of the cables ( 2 to 24 core ) with proper clamping 156 removal of broken bolts of jb covers & fixing new bolts. 157 replacement of cable gland / pipe fitting / tube fitting, where cable laying / pipe laying / tube laying is not desired. size upto 2 and all rating & material. 158 tray & other misc. jobs tray / angle iron laying ( for tubing / cables ) fixing of supports including related cutting, welding, fitting jobs for different sizes: 159 size : 2 / 50 mm wide 160 size : 4 / 100 mm wide 161 size : 8 / 200 mm wide 162 size : 16 / 400 mm wide 163 al. tray cover fixation size 200 mm. 164 al. tray cover fixation size 400 mm. 165 tray / angle iron removing ( for tubing / cables ) including related cutting & grindingjobs for different sizes: 166 size : 2 / 50 mm wide 167 size : 4 / 100 mm wide 168 size : 8 / 200 mm wide 169 size : 16 / 400 mm wide 170 al. tray cover removal size 200 mm. 171 al. tray cover removal size 400 mm. 172 fabrication / re conditioning & erection of gi / ms sheet canopies / protection covers for transmitters / other instruments of size upto 1 sq m. area 173 fabrication of supports of structural steel 174 fabrication of stanchions for mounting insts. as per standards 175 dismentling of structure by opening bolts, gas cutting, removal & shifting from site to scrap stores 176 removing of canopy / protection cover for maintenance job of instrument and fixing back ( any size ) 177 isolation valves & gland packing jobs fixing of isolation valves ( socket weld / threaded type ) including fitting, welding & pressure testing job for following sizes : 178 size 1 / 4, upto 1500# lbs rating cs / ss 179 size 1 / 2, 1500# 3000# lbs rating cs / ss 180 size 1, 1500# 3000# lbs rating cs / ss 181 size 2, 1500# 3000# lbs rating cs / ss 182 removal of isolation valves ( socket weld / threaded type ) including fitting, cutting job irrespective of material, rating & upto size 2 inclusive 183 gland packing of isolation valves / control valves of any sizes 184 opening of flanges, cleaning, repair & polishing of gasket surfaces ( including lapping of ring / lens joint type ) and boxing up as & when required. size upto 4 and all ratings 185 dismentaling, cleaning and assembling of condensate drain system in passivation air comprs. ( k 3 ) 186 control valve jobs 187 opening of control valve from actuator / bonnet / line upto 2 size & any rating 188 opening of control valve from actuator / bonnet / line upto 3 size & any rating 189 opening of control valve from actuator / bonnet upto 4 size & any rating 190 opening of control valve from actuator / bonnet upto 5 & 6 size & any rating 191 opening of control valve from actuator / bonnet upto 8 & 10 size & any rating 192 opening of control valve from actuator / bonnet above 10 size & any rating 193 fixing back of control valve actuator / bonnet on the body / line upto 2 size & any rating 194 fixing back of control valve actuator / bonnet on the body / line upto 3 size & any rating 195 fixing back of control valve actuator / bonnet on the body upto 4 size & any rating 196 fixing back of control valve actuator / bonnet on the body upto 5 & 6 size & any rating 197 fixing back of control valve actuator / bonnet on the body upto 8& 10 size & any rating 198 fixing back of control valve actuator / bonnet on the body above 10 any rating 199 removal of valve positioner with its pneumatic / electrical connection 200 removal of pilot relay / lockup relay, limitswitch alongwith pneumatic / electrical connection 201 removal of volume booster alongwith its pneumatic connection 202 removal of i / p convertor alongwith pneumatic / electrical connection 203 removal of solenoid valve alongwith pneumatic / electrical connection 204 fixing of valve positioner alongwith pneumatic / electrical connection 205 fixing of pilot relay / lockup relay, limitswitch alongwith pneumatic / electrical connection 206 fixing of volume booster alongwith its pneumatic connection 207 fixing of i / p convertor alongwith its pneumatic / electrical connection 208 fixing of solenoid valve alongwith pneumatic / electrical connection 209 replacement of actutor diapragm ( pneumatic ) of any size actuator 210 removal of piston / power cylinder alongwith pneumatic connection 211 fixing of piston / power cylinder alongwith pneumatic connection 212 lapping of plug , seat & other sealing surface of control valves 213 greasing of control valve parts 214 removal of air filter regulator set with fittings 215 fixingof air filter regulator set with fittings 216 jobs in bagging plant area 217 removal and cleaning of level probes & refixing 218 cleaning of machines, weigh pans, solenoid valves, power cylinders etc. 219 replacement of broken weigh pan assembly of bagging machines & repairing by doing necessary cutting / welding, cleaning etc. 220 cleaning of avery / tulaman pre determined weighing scales ( check weighers ) 221 cleaning of et 6 belt weighers framework and related equipments 222 assistance in calibration of bagging machines by putting weights 223 fixing of power cylinder of piston dia.upto 100mm on the machine 224 removing of power cylinder of piston dia.upto 100mm from machine 225 removal of solenoid valve spool type 5 ports 226 fixing of solenoid valve spool type 5 ports 227 laying / removing pvc / nylon tubing upto 12mm size 228 filling of oil in bagging machine air regulators 229 replacement of proximity sensor in pandoor / bagholder of bagging machines 230 replacement & repairing of broken feed gate assembly of bagging machines by doing necessary cutting / welding, cleaning etc. 231 removing, cleaning & fixing of anti vibration pads in bagging machines 232 replacement & repairing of brokenbag holder assembly of bagging machines by doing necessary cutting / welding, cleaning etc. 233 replacement of load cell ( including all accessories ) of urea bunker level measuring system / urea belt weigher / weigh bridges 234 other misc.jobs 235 removing of manual call points mcp ) including accessories 236 refixing of manual call points mcp ) including glanding and termination 237 removing of heat, flame or smoke detectors & termination 238 refixing of heat, flame or smoke detectors & termination 239 painting of control valves, actuators including accessories & other insts. with mounting stand 240 writing of tag nos. on instruments, control valves, etc 241 cleaning of instruments, control valves, local panels, ccr cabinets etc 242 laying of heat detector cable on cable trays & their connections 243 removing of heat detector cable on cable trays 244 removal of speed / vibration / axial displacement probe / extension cable 245 fixation of speed / vibration / axial displacement probe / extension cable 246 removal of field tachometer / speed indicator 247 fixation of field tachometer / speed indicator 248 control panel cutting ( for cable entry or providing new instrument ) 249 removal of low explosive limit detector / ammonia detector / co detector 250 fixation of low explosive limit detector / ammonia detector / co detector 251 transportation of instruments / materials from respective plant to instrument workshop / store 252 transportation of instruments / materials from instrument workshop / store to respective plants 253 removal of uv flame scanner & cleaning 254 fixation of uv flame scanner 255 removal of weephole probe in urea reactors 256 fixing of weephole probe in urea reactors 257 removal, cleaning / washing and fixing of suction air filters of ccr / lcr control cabinets ( dcs / esd / ops / his / vms & printer consoles ) 258 panel cooling fans removing, cleaning & checking 259 panel cooling fans fixing ( including mounting arrangement ) 260 to assist nfl employees in executing various instrument maintenance jobs in routine day to day maintenance 261 helper ( un skilled ) 262 instrumentation technician ( skilled ) 263 supply of contract labour for unplanned / unforeseen plant breakdown jobs & planned shutdown 264 instrumentation technician ( skilled ) 265 instrumentation fitter ( skilled ) 266 helper / mazdoor ( un skilled ) 267 rigger ( skilled ) 268 welder ( skilled ) 269 electrician ( skilled ) 270 note: party may fill any rate in soqr sl. no. 14 & 15 but not less than minimum amount as ilustreted in price bid format part b of nit. => limited...

Madhya Pradesh Power Generating Company Limited - Madhya Pradesh

29165120 supply, installation, testing and commissioning of co2 fire suppression system including dismantling of old co2 system to protect generator at 2x15 mw bhps ii silpara. , seamless cylinders, ccoe approved capacity 45.0 kg complete in all respect if any existing cylinder failed in tests (on actual basis) , refilling of co2 gas with 99.9 % purity, each cylinder gas capacity 45.0 kg , co2 cylinder bank along with weighing device mounting rail (suitable for 08 nos. of 45.0 kg capacity co2 cylinders) & accessories like seamless header, nut bolts, rubber gaskets etc. , master valve with solenoid & manual lever , slave valve with pneumatic actuator & manual lever , non return valve suitable for fixing at co2 discharge header, make: tpfps/equivalent , high pressure discharge hose , high pressure pneumatic actuation hose , pilot cylinder 3.0 ltr. water capacity filled with 2.0 kg n2 gas fitted with solenoid valve with manual lever to operate directional valve , 32 nb co2 directional valve with pneumatic actuator & limit switch , 25 nb co2 directional valve with pneumatic actuator & limit switch , continuous gas weighting monitor led type , continuous gas weight monitor control panel suitable to connect 10 nos. of gas weight monitors common for all type of weight monitors , manifold safety valve , pressure switch , discharge warning display unit , inhibit/ abort switch , manual gas release , electronic dual tone hooter with flashing lamp for indoor application , m s seamless pipe sch 80 with all required tee, reducers, flanges, gaskets, nut bolts, etc as required. size 32 nb , m s seamless pipe sch 80 with all required tee, reducers, flanges, gaskets, nut bolts, etc as required. size 25 nb , 2 c x 1.5 sqmm copper armoured frls fire survival cable including all consumables , conventional fire detection & alarm panel with gas release modules working on 4 zones with 02 nos. spare zone , smoke detector/ probe type fixed temperature heat detector with junction box , high pressure discharge nozzle with bowl , hydro test of seamless cylinders , painting of the old co2 cylinders with two coat of post office enamel red paint over one coat of red oxide primer etc. complete in all respect , installation, testing & commissioning of the system...

Madhya Pradesh Power Generating Company Limited - Madhya Pradesh

29165118 design, supply, erection, testing and commissioning of co2 fire suppression system for hydro generator protection at 2x10 mw bhps iv jhinna. , seamless cylinders, ccoe approved capacity 45.0 kg complete in all respect with gas and duly painted ( required if any co2 cylinder fails in h.p. tests , refilling of co2 gas with 99.9 % purity, each cylinder gas capacity 45.0 kg , hp test of cylinders , co2 cylinder bank along with weighing device mounting rail ( suitable for 08 nos. of 45.0 kg capacity co2 cylinders ) & accessories like seamless header, nut bolts, rubber gaskets etc. , master valve with solenoid & manual lever , sleeve valve with pneumatic valve , non return valve suitable for fixing at co2 discharge header , high pressure discharge hose , high pressure interconnection hose , pilot cylinder 3.0 ltr. water capacity filled with 2.0 kg n2 gas fitted with solenoid valve with manual lever to operate directional valve , 32 nb co2 directional valve for initial discharge , 25 nb co2 directional valve for delayed extended discharge , online continuous gas monitor led type , weight loss gas monitor control panel suitable to connect 20 nos. of gas weight monitors common for all type of weight monitors , manifold safety valve , discharge pressure switch , discharge warning display unit 24 v dc , inhibit / abort switch , manual gas release , electronic dual tone hooter with flashing lamp for indoor application , m s seamless pipe sch 80 with all required tee, reducers, flanges, gaskets, nut bolts, etc as required. size 32 nb , m s seamless pipe sch 80 with all required tee, reducers, flanges, gaskets, nut bolts, etc as required. size 25 nb , 2 c x 1.5 sqmm copper armoured frls fire survival cable including all consumables , conventional fire detection & alarm panel with gas release modules working 2 zones with battery backup , smoke detector / probe type fixed temperature heat detector with junction , high pressure discharge nozzle with bowl , installation, testing & commissioning of system , special tool kit required for maintenance and troubleshooting , seamless m.s. pipe of schedule grade with required forged fittings., m.s. support with bolts, u clamps etc. duly painted in red and fixing pipes. m.s. seamless astm 1 106, sch 40 , transportation charges include lodging and boarding...

National Handloom Development Corporation Limited - Madhya Pradesh

27284777 procurement of spares ( make notifier ) for fire fighting system installed at power houseof omkareshwar power station , loop card for nfs2 640 ( e ) fire alarm control panel , multisensor smoke detector model no . fapt851 , photoelectric smoke detector model no . fsp851 , control module model no . fcm 1 , heat detector fst 851 r , hooter ( sys hs ) , control module ( relay mode ) model no . frm 1 , monitor module model no . fmm 101 , note: 1 ) transit insurance shall be in the scope of nhdc ltd . 2 ) bidder should quote unit basic rate inclusive of packing , forwarding , handing and frieght charges , for f . o . r . omkareshwar power station in column no . 5 . 3 ) bidder shall quote unit cgst , sgst amount in column no . 6 &7 respectively for intra state supply or shall quote igst amount in column no . 8 for inter state supply . 4 ) bidders are requested to verify carefully the amount entered by them in respective column and the amount generated automatically through formulae before uploading it to the portal...

National Handloom Development Corporation Limited - Madhya Pradesh

27257351 up gradation by replacement of obsolate components of fire alarm system for power house and switchyard at indira sagar power station , narmada nagar , district khandwa ( m . p . ) . tsn no isps/p/mw/ 2020 21/096 , supply of siga cc1 ( connected to hooter ) , supply of monitor module ( connected to rchd ) siga ct1 , supply of delugevalve ( only spares are required ) , supply of repeater panel , supply of monitor module siga ct1 , supply of monitor module ( connected to air sampling device asd ) siga ct1 , air sampling device ( asd ) , supply of optical smoke detector , supply of heat detector , supply of rate compensated heat detector , supply of strobe cum hooter , supply of manual call point , supply of fire alarm control panel ( facp ) with computer , supply of linear heat sensing cable ( lhsc ) , supply of bulb detector , supply of lcpdv ( local control panel for deluge valve ) complete in all respects including control module and monitor module , installation of siga cc1 ( connected to hooter ) , installation of monitor module ( connected to rchd ) siga ct1 , installation of delugevalve ( only spares are required ) , installation of repeater panel , installation of monitor module siga ct1 , installation of monitor module ( connected to air sampling device asd ) siga ct1 , air sampling device ( asd ) , installation of optical smoke detector , installation of heat detector , installation of rate compensated heat detector , installation of strobe cum hooter , installation of manual call point , installation of fire alarm control panel ( facp ) with computer , installation of linear heat sensing cable ( lhsc ) , installation of bulb detector , installation of lcpdv ( local control panel for deluge valve ) complete in all respects including control module and monitor module...

National Thermal Power Corporation Limited - Madhya Pradesh

26405016 procurement of smoke detectors fire alarm system for adm building . , wireless type fire control panel , wireless type smoke detector , wireless type heat detector , wireless type manual call point switch , wireless type electronic hooter , fap repeater panel bu 70 , flashr alarm card;pt#fam1;fire alarm;st1...

National Handloom Development Corporation Limited - Madhya Pradesh

26172791 procurement of spares ( make notifier ) for fire fighting system installed at power house of omkareshwar power station , loop card for nfs2 640 ( e ) fire alarm control panel , multisensor smoke detector model no . fapt851 , photoelectric smoke detector model no . fsp851 , control module model no . fcm 1 , heat detector fst 851 r , hooter ( sys hs ) , control module ( relay mode ) model no . frm 1 , monitor module model no . fmm 101 , note: 1 ) transit insurance shall be in the scope of nhdc ltd . 2 ) bidder should quote unit basic rate inclusive of packing , forwarding , handing and frieght charges , for f . o . r . omkareshwar power station in column no . 5 . 3 ) bidder shall quote unit cgst , sgst amount in column no . 6 &7 respectively for intra state supply or shall quote igst amount in column no . 8 for inter state supply . 4 ) bidders are requested to verify carefully the amount entered by them in respective column and the amount generated automatically through formulae before uploading it to the portal...

Bharat Sanchar Nigam Limited - Madhya Pradesh

19934773 tender for supplying, installation, testing & commissioning of 3 nos. 1.5 tr inverter split ac at qa & inspection circle (t&d), jabalpur. 1 engine 2 alternator (brushless) 3 battery ( lead acid / mntc. free) 4 hv switchgear ( vacuum circuit breaker / sf6) 5 transformer (oil filled / dry type a)above 400 kva b)up to 400 kva 6 air circuit breaker 7 mccb(ics=icu) 8 sdf units 9 power contactors 10 change over switch 11 intelligent apfc relay 12 bus bar trunking / sandwiched bus duct 13 power capacitors (mpp/app) 14 digital / kwhr meter 15 cold shrink ht/lt cable joint 16 rubber matting 17 mcb / isolator / elcb / rccb / distribution board 18 ms / pvc conduit 19 cable tray 20 ht/lt cables 21 pvc insulated copper conductor wire 22 centrifugal pump 23 submersible pump 24 motors 25 fresh air fans 26 starter 27 single phase preventer 28 gi/ms pipe 29 foot valve 30 gate valve 31 compressors 32 resin bonded glass wool 33 expanded polystyrene 34 gauge 35 controls 36 fine filter 37 gi sheet 38 heat detector 39 ionization detector 40 photo electric smoke detector 41 fire panel (microprocessor based) 42 sprinkler / hose reel & hose pipe 43 fire extinguisher 44 lift....

National Thermal Power Corporation Limited - Madhya Pradesh

17103533 procurement of spares of emulsifiers of fire protection system: 10 clapper assembly 6v / v spares.710040411 20 clapper assembly 4 valve .71040611 30 diaphragm for deluge valve 150nb hd make 40 diaphragm for deluge v / v 100nb hd make. 50 seat rubber for deluge v / v 150nb hd make 60 seat rubber for deluge v / v 100nb hd make 70 rubber clamp for deluge v / v150nb hd make 80 rubber clamp deluge v / v 100nb hd make. 90 clamp ring for deluge v / v 150nb hd make. 100 clamp ring for deluge v / v 100nb hd make. 110 wet pilot ( hydraulic ) trim for deluge v / v 120 wet pilot ( hydraulic ) trim for deluge v / v 130 diaphragm for deluge valve 80 nb 140 clapper assembly compelte for 80 nb dv 150 dv a:angle valve 1 160 mulsifyre system 1 / 2 check valve 170 mulsifyre system check valve 20mm dia 180 dv a:drip valve 1 / 2 190 spray nozzle ( hvw spray nozzle ) , for ffs 200 projectors hvw k 18 x 80 degree 210 hvw spray nozzle hv as, k 23, hdfire 220 mvw spray nozzles k22 x 120 deg 230 mvw spray nozzles, size:k30 x 120 deg. 240 mvw spray nozzles; size:k35 x 120 deg. 250 mvw spray nozzles; size: k41 x 120 deg. 260 mvw nozzle k64x120 degree, 1 / 2npt mvw spray nozzles size: k79 270 x 120 deg. 280 heat detector ( qb type ) / temp. 93d.c 290 q.b sprinkler 79 degree centigrade 300 mvw spray nozzles ; size: k51 x 120 deg....

Bharat Sanchar Nigam Limited - Madhya Pradesh

16427107 tender for repair and maintenance of electrical assets 1 engine 2 alternator (brushless) 3 battery ( lead acid / mntc. free) 4 hv switchgear ( vacuum circuit breaker / sf6) 5 transformer (oil filled / dry type a)above 400 kva b)up to 400 kva 6 air circuit breaker 7 mccb(ics=icu) 8 sdf units 9 power contactors 10 change over switch 11 intelligent apfc relay 12 bus bar trunking / sandwiched bus duct 13 power capacitors (mpp/app) 14 digital / kwhr meter 15 cold shrink ht/lt cable joint 16 rubber mattin, 17 mcb / isolator / elcb rccb / distribution board 18 ms / pvc conduit 19 cable tray 20 ht/lt cables 21 pvc insulated copper conductor wire 22 centrifugal pump 23 submersible pump 24 motors 25 fresh air fans 26 starter 27 single phase preventer 28 gi/ms pipe, 29 foot valve 30 gate valve 31 compressors 32 resin bonded glass wool 33 expanded polystyrene 34 gauge 35 controls 36 fine filter 37 gi sheet 38 heat detector 39 ionization detector 40 photo electric smoke detector 41 fire panel (microprocessor based) 42 sprinkler / hose reel & hose pipe 43 fire extinguisher 44 lift etc....

Indian Council Of Medical Research - Madhya Pradesh

16102680 sale of condemned general scrap & obsolete e waste items: 74 high pressure burner top high pressure burner top 75 air cone 76 complete nozzle holder brass complete nozzle holder brass 77 electrodes cap 78 sensor for tci sensor for tci sensor 79 steam tree assembly without steam stop valve 80 piston for feed water pump piston for feed water pump piston for feed water pump 81 temperature gauge 82 nrv – 40mm nrv – 20mm nrv – 20mm 83 pipe wrench – 12 pipe rinch 14 pipe rinch 18 pipe rinch 24 84 screw spanner 12 85 torch light 3 cell aluminium 86 economizer inside part blr no 2 economizer inside part blr no 3 87 electrodes 88 inlet line of softener 89 geyser 25 ltrs 90 geyser 35 ltrs 91 geyser 50 ltrs 92 sintex water tank 500 ltr 93 sintex water tank 1000 ltr 94 sintex water tank 3000 ltr 95 sintex water tank 4000 ltr 96 sintex water tank 5000 ltr 97 sintex water tank 5000 ltr 98 br bib cock (all types) 99 br spandle 100 brass ball cock 101 brass gate valve 102 door closer (open) 103 door closer (concealed) 104 floor spring 105 pvc connection pipe 18 106 pvc connection pipe 24 107 pvc seat cover 108 pvc tank cover 109 syphon fittings 110 pvc ball cock 111 pvc handle 112 aluminum handle 113 tower bolt 114 aluminium scrap 115 aluminium window scrap 116 mortice lock 117 door spring 118 miscellaneous scrap 119 shaft bush 1555 120 shaft bush 325 121 impeller 1555 122 impeller 325 123 ewc 124 ceramic cistern 125 ceramic washbasin 126 drill machine 127 cutter machine 128 monkey plas 129 rachel die 130 silicon sealant gun 131 fire extinguisher 4.5kg 132 fire extinguisher 2kg 133 fire extinguisher water co2 9 ltr 134 fire extinguisher abc 5kg 135 hose pipe 63mm 15 mtr long 136 rubber hose reel 137 smoke detector 138 heat detector 139 manual break glass unit 140 fire alarm hooter 141 air valve 142 writing table dh 1 20, dh 2 22, nh 1 & 2 34, sarai 19 ...

Bharat Sanchar Nigam Limited - Madhya Pradesh

14997618 providing service connection and misc electrical work for ph viii.4 bts amarwada ii & tamiya ii dist chhindwara ( first recall) 1 2 3 4 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 compressors resin bonded glass wool expanded polystyrene starter single phase preventer gi/ms pipe foot valve gate valve pvcinsulatedcopperconductorwire centrifugal pump submersible pump motors fresh air fans rubber matting mcb/isolator/elcb/rccb / distribution board ms/ pvc conduit cable tray ht/lt cables intelligent apfc relay busbartrunking/sandwichedbus duct power capacitors ( mpp / app ) digital / kwhr meter cold shrink ht / lt cable joint air circuit breaker mccb ( ics = icu ) sdf units power contactors change over switch battery lead acid / maintenance free ) hvswitchgear(vaccumcircuitbreaker / sf6 ) 5 transformer(oilfilled/drytype ) [a] above 400 kva [b] upto 400 kva engine alternator ( brushless)34 35 36 37 38 39 40 41 42 43 44 fine filters heat detector lift ionization detector photo electric smoke detector fire panel (microprocessor based) sprinkler/ hose reel &hose pipe fire extinguisher gi sheet gauge controls...

Bharat Heavy Electricals Limited - Madhya Pradesh

11572102 supply of 1 ) heat detector cerberus pyrotronics, siemens make ( model no. dt 200cs as per catalog no. 6131 ) or equivalent for co2 type fire fighting system. qty: 12 no, heat detector cerberus pyrotronics, siemens make ( => limited tender...

Bharat Sanchar Nigam Limited - Madhya Pradesh

9486087 detection and replacement of faulty electrical items :1 engine 2 alternator (brushless) 3 battery ( lead acid / mntc. free) 4 hv switchgear ( vacuum circuit breaker / sf6) 5 transformer (oil filled / dry type a)above 400 kva b)up to 400 kva 6 air circuit breaker 7 mccb (ics=icu) 8 sdf units 9 power contactors 10 change over switch 11 intelligent apfc relay 12 bus bar trunking sandwiched bus duct 13 power capacitors (mpp/app) 14 digital / kwhr meter 15 cold shrink ht/lt cable joint 16 rubber matting 17 mcb / isolator / elcb rccb / distribution board 18 ms / pvc conduit 19 cable tray 20 ht/lt cables 21 pvc insulated copper conductor wire 22 centrifugal pump 23 submersible pump 24 motors 25 fresh air fans 26 starter 27 single phase preventer 28 gi/ms pipe 29 foot valve 30 gate valve 31 compressors 32 resin bonded glass wool 33 expanded polystyrene 34 gauge 35 controls 36 fine filter 37 gi sheet 38 heat detector 39 ionization detector 40 photo electric smoke detector 41 fire panel (microprocessor based) 42 sprinkler / hose reel & hose pipe 43 fire extinguisher 44 lift 45 drier 46 expansion valve at various bts sites under indore ssa. ( ph. ii for 10 sites )...

Bharat Sanchar Nigam Limited - Madhya Pradesh

8597870 repairing of 2 nos. lift at t&d bldg. jabalpur list of approved makes of products 1 engine 2 alternator ( brushless ) 3 battery ( lead acid / mntc. free ) 4 hv switchgear ( vacuum circuit breaker / sf6 ) 5 transformer ( oil filled / dry type a ) above 400 kva b ) up to 400 kva 6 air circuit breaker 7 mccb ( ics=icu ) 8 sdf units 9 power contactors 10 change over switch 11 intelligent apfc relay 12 bus bar trunking / sandwiched bus duct 13 power capacitors ( mpp / app ) 14 digital / kwhr meter 15 cold shrink ht / lt cable joint 16 rubber matting 17 mcb / isolator / elcb rccb / distribution board 18 ms / pvc conduit 19 cable tray 20 ht / lt cables 21 pvc insulated copper conductor wire 22 centrifugal pump 23 submersible pump s. no. item 24 motors 25 fresh air fans 26 starter 27 single phase preventer 28 gi / ms pipe 29 foot valve 30 gate valve 31 compressors 32 resin bonded glass wool 33 expanded polystyrene 34 gauge 35 controls 36 fine filter 37 gi sheet 38 heat detector 39 ionization detector 40 photo electric smoke detector 41 fire panel ( microprocessor based ) 42 sprinkler / hose reel & hose pipe 43 fire extinguisher 44 lift...

Not Specified - Madhya Pradesh

1647002 design, supply, installation, commissioning, integration and trial of centralized computer based smoke cum heat detector and addressable wireless fire detection and alarm system on turnkey basis...

Not Specified - Madhya Pradesh

1644705 design, supply, installation, commissioning, integration and trial of centralized computer based smoke cum heat detector and addressable wireless fire detection and alarm system on turnkey basis...