Madhya Pradesh Power Generating Company Limited - Madhya Pradesh

34240884 procurement of emergency stop push button, contact element, panel lock and control for ht lt switchgear for emd iv, stps, sarni. procurement of emergency stop push button, contact element, panel lock and control for ht lt switchgear for emd iv, stps, sarni. , emergency stop push button, contact element, panel lock and control for ht / lt switchgear , mushroom head push button stay put ( press to lock, turn to release ) with 1 nc contact reference: rcb2 bs54 , contact element – 1 nc reference: rb2 be 102 , contact element – 1 no reference: rb2 be 101 , push button actuators with carrier & contact element non –illuminated, flush spring return push button with 1 no block reference: rcb2 ba31 , panel lock with zinc key ( pin type ) 20 mm suitable for m / s c&s make lt switchgear dol, rdol & sfu feeder reference: pin type 20mm , panel lock with zinc key ( triangle type ) 20 mm suitable for m / s c&s make lt switchgear dol, rdol & sfu feeder reference: triangle type – 20mm , control relay – 10amps, contact configuration 2no+2nc, 240v ac control supply. reference: tca3 dn22 , add on block for contactor rating 10a, front mounted, contact configuration 2 no+ 2 nc, reference: ta1 dn22 , mini contactor, control relay – 10amps, contact configuration 2no+2nc, 220v dc control supply. reference: tca3 m22 , mini contactor, control relay – 10amps, contact configuration 2no+2nc, 240v ac control supply. reference: tca2 mcc...

Madhya Pradesh Madhya Kshetra Vidyut Vitaran Company Limited - Madhya Pradesh

34185888 estimate for shifting 33 / 11 kv sub station ambah from 132 kv ehv sub station ambah to out side under ambah d / c in ( o&m ) dn. ambah 2 earthing set ( dtr earthing ) as per circular no 1516 dated 17.03.08 3 11 kv 1500 kvar auto switch capacitor bank including associated 4 erection cost of 11 kv 1500 kvar auto switch capacitor bank including associated 5 11 kv ab switch 400 amp with complete accessories. 6 erection cost of 11 kv ab switch 400 amp with complete accessories. 7 11 kv composite polymer disc insulators 8 11 kv d.o. fuse unit polymer type 9 erection cost of 11 kv d.o. fuse unit polymer type 10 11 kv pt single phase 11 erection cost of 11 kv pt single phase 12 11 kv polymer lightening arrestor gapless type 13 erection cost of 11 kv polymer lightening arrestor gapless type ( 03 no. ) 14 11 kv polymer pin insulator 15 erection cost of11 kv polymer pin insulator 16 11 kv strain hardware ( t&c type ) fittings 17 11 kv vcb, outdoor porcelain clad type with complete structure and accessories 18 erection cost of 11 kv vcb, outdoor porcelain clad type with complete structure and accessories 19 11 kv xlpe armoured cable 3x150 sq.mm. 20 11 kv control & relay panel with numerical static relay for 2 feeder protection 21 erection cost of11 kv control & relay panel with numerical static relay for 2 feeder protection 22 11 kv.c.ts. ( outdoor dry type ) 300 150 / 5 5 amps 23 erection cost of11 kv.c.ts. ( outdoor dry type ) 300 150 / 5 5 amps 24 11kv control & relay panel with numerical static relay for 1 f + 1 t protection 25 erection cost of11kv control & relay panel with numerical static relay for 1 f + 1 t protection 26 33 kv ct outdoor type 400 200 / 5 5 amp 27 erection cost of 33 kv ct outdoor type 400 200 / 5 5 amp 28 33 kv composite polymer ab switch 29 erection cost of 33 kv composite polymer ab switch 30 33 kv composite polymer disc insulators 31 33 kv polymer lightening arrestor gapless type 32 erection cost of33 kv polymer lightening arrestor gapless type ( 03 no. ) 33 33 kv strain hardware ( t&c type ) fittings suitable for panther 34 33 kv vcb, outdoor porcelain clad type with complete structure and accessories 35 erection cost of33 kv vcb, outdoor porcelain clad type with complete structure and accessories 36 33 kv, 10 kn pin composite polymer insulator 37 erection cost of 33 kv, 10 kn pin composite polymer insulator 38 33 kv / 110v 3 ph 4 wire ct / pt 400 200 / 5 amp outdoor oil immersed type, class 0.2s 39 erection cost of33 kv / 110v 3 ph 4 wire ct / pt 400 200 / 5 amp outdoor oil immersed type, class 0.2s 40 33kv control & relay panel with numerical static relay for 1 f + 1 t protection 41 erection cost of 33kv control & relay panel with numerical static relay for 1 f + 1 t protection 42 3ph 4w 3x63.5v lb=1a, imax=2a, ht trivector meter, 0.2s, gsm, ( store n forward ) ehv 43 acdb 415 v, along with three phase neutral voltmeter, three phase ammeter 44 erection cost of acdb 415 v, along with three phase neutral voltmeter, three phase ammeter 45 acsr panther conductor 0.20 sq. inch ( 200 sq.mm al.eq. ) 46 erection cost of acsr panther conductor 0.20 sq. inch ( 200 sq.mm al.eq. ) ( 03 no. cond. ) 47 aluminium paint 48 erection cost of aluminium paint 49 bi metallic clamp for power transformer of brass flat 50x50x10mm 50 erection cost of bi metallic clamp for power transformer of brass flat 50x50x10mm 51 concreting of rail / hbeam supports @0.65 cmt.per pole including muffing of pole 52 labour for concreting of rail / hbeam supports @0.65 cmt.per pole including muffing of pole 53 concreting of foundation of vcb ( 1:3:6 ) @ 3.5 cmt per vcb plinth 54 erection cost of concreting of foundation of vcb ( 1:3:6 ) @ 3.5 cmt per vcb plinth 55 labour for pit diging for vcb size ( 3x2x0.3 ) =3.6 mtr. 56 copper control cable 12 core. 2.5 sq.mm. ( unarmoured ) 57 copper control cable 2 core. 2.5 sq.mm. ( unarmoured ) 58 erection cost ofcopper control cable 2 core. 2.5 sq.mm. ( unarmoured ) 59 d.c. cross arms 8 channel ( 100x50x6mm ) 60 erection cost of d.c. cross arms 8 channel ( 100x50x6mm ) 61 d.o.mounting channel 75x40x6 mm 62 erection cost ofd.o.mounting channel 75x40x6 mm 63 dtr 11 / 0.4 kv bis ee level 2 100 kva 64 handling & installation ofdtr 11 / 0.4 kv bis ee level 2 100 kva 65 danger boards enamelled 11 kv 66 erection cost of danger boards enamelled 11 kv 67 danger boards enamelled 33 kv 68 erection cost of danger boards enamelled 33 kv 69 direct curent distribution board ( dcdb ) 24 volts indoor floor / wall 70 erection cost ofdirect curent distribution board ( dcdb ) 24 volts indoor floor / wall 71 earthing coil of 115 turns of 50 mm.dia and 2.5 mtr lead of 4.0 mm g.i wire 72 earthing of new 33 / 11 kv s / s as per schedule g 3 ( for black cotton soil ) 73 h beams 152 x 152 mm., 37.1 kg. / meter 11 meter. long 74 erection cost ofh beams 152 x 152 mm., 37.1 kg. / meter 11 meter. long 75 h beams 152 x 152 mm., 37.1 kg. / meter 9 meter. long 76 erection cost ofh beams 152 x 152 mm., 37.1 kg. / meter 9 meter. long 77 h.beam clamps 65x8mm flat 78 h.beam back clamps 65x8mm flat ( in numbers ) 79 iron steel scrap 80 led lamp with 90 watt ( complete ) 81 erection cost of led lamp with assesary 82 lt distribution box with isolator & hrc fuse 100 kva dtr ( 300a & 6 j hook ) 83 erection cost of lt distribution box with isolator & hrc fuse 100 kva dtr ( 300a & 6 j hook ) 84 m s angle 75x75x6mm 85 febrication for 33 kv top clamp 75x75x6mm 86 erection cost of33 kv top clamp 75x75x6mm 87 m s channel 100x50mm 88 febrication for d. c cross arm 4.8 meterchannel ( 100x50x6mm ) 89 erection cost of d. c cross arm 4.8 meterchannel ( 100x50x6mm ) 90 febrication for d. c cross arm 5 centerchannel ( 100x50x6mm ) 91 erection cost of d. c cross arm 5 centerchannel ( 100x50x6mm ) 92 m.s.nuts and bolts 93 ms strain plate 65x8mm 250mm long 94 marshelling box with 10 no. connectors 95 erection cost ofmarshelling box with 10 no. connectors 96 ptr fndn.cncrt.:1:1.5:3 rio 5.634, 1:5:8 rio 7.545 cmt&m.s.flat / rod 324.87 kg 97 erection cost of ptr fndn.cncrt.:1:1.5:3 rio 5.634, 1:5:8 rio 7.545 cmt&m.s.flat / rod 324.87 kg 98 pvc insulated 2 core armoured 4 sqmm aluminium conductor 1100 volts 99 pvc insulated 4 core armoured 10 sqmm aluminium conductor 1100 volts1 100 red oxide paint 101 erection cost ofred oxide paint 102 sheet metal meter box suitable for h.t. static travector meters with ttb 103 stay gi wire 7 / 4.00 mm. ( 7 / 8 swg ) 104 stay set without stay wire 20 mm. ( painted ) 105 erection cost of stay set without stay wire 20 mm. ( painted ) 106 stay wire 7 / 3.15 mm. ( 7 / 10 swg ) 107 stay clamp a type 65x8mm ms flat r.s. joist 108 stay set complete without stay wire 16 mm. ( painted ) 109 erection cost ofstay set complete without stay wire 16 mm. ( painted ) 110 stone block / pre cast block for base pedding ( 450x450x75mm ) 111 straight through heat shrinkable cable joint kit with lug 11kv xlpe 3c 240sqmm 112 tee clamps for panther 113 erection cost of tee clamps for panther 114 three phase static energy meters 20 80 amps.with l.s. & tod facility with box 115 transformer clamping set 50x50 x6 mm angle 460mm long 116 transformer mounting channel ( 100x50x6 mm. ) 117 erection cost of transformer mounting channel ( 100x50x6 mm. ) 118 xlpe 1 core unarmoured 120 sqmm aluminium conductor 1100 volts 119 xlpe 1 core unarmoured 50 sqmm aluminium conductor 1100 volts 120 fire extinguisher cartridge co2 10 kgs 121 furniture for control room table 600mmx 900mm 1no., chair 3no., 122 laying of metal in yard:100 mm thick metalling with 40 mm size b.t. 123 p&f perfo cable tray 300 wide, 2 thick fix 45x45x5 ms angle grouted cc 1:24 124 ing brick massonery 0.6x0.6m inner, flag stone cover:18 no. earth pit 125 dismantling charges @ 50 % of erection cost 126 gst 18% 127 task name: 33 kv line on h beam 13 mtr long ( 0.21 km ) 128 h beams 152 x 152 mm., 37.1 kg. / meter 13 meter. long 129 erection cost of h beams 152 x 152 mm., 37.1 kg. / meter 13 meter. long 130 stay gi wire 7 / 4.00 mm. ( 7 / 8 swg ) 131 h.beam clamps 65x8mm flat 132 stone block / pre cast block for base pedding ( 450x450x75mm ) 133 red oxide paint 134 erection of red oxide paint 135 aluminium paint 136 erection cost of aluminium paint 137 anti climbing device ( barbed wire ) gs 2.24 mm dia ( 14 swg ) 138 erection of anti climbing device ( barbed wire ) gs 2.24 mm dia ( 14 swg ) 139 danger boards enamelled 33 kv 140 erection cost of danger boards enamelled 33 kv 141 aluminium binding wire and tape 142 33 kv v cross arm 1.5 mtr ( 5ft ) centre made from 75x75x6mm angle 143 fixing of 33 kv v cross arm with top clamp 144 m.s.nuts and bolts 145 h.beam back clamps 65x8mm flat ( in numbers ) 146 33 kv top clamps 75x75x6 mm angle 147 earthing coil of 115 turns of 50 mm.dia and 2.5 mtr lead of 4.0 mm g.i wire 148 33 kv, 10 kn pin composite polymer insulator 149 erection cost for33 kv, 10 kn pin composite polymer insulator 150 aaac dog conductor 0.10 sq. inch ( 100 sq.mm. al.eq. ) 151 erection cost of aaac dog conductor 0.10 sq. inch ( 100 sq.mm. al.eq. ) ( 03 no. cond. ) 152 jointing sleeves suitable for dog ( 100sq.mm.al. eq. ) aaac conductor 153 stay set without stay wire 20 mm. ( painted ) 154 erection cost for stay set without stay wire 20 mm. ( painted ) 155 concreting of rail / hbeam supports @0.65 cmt.per pole including muffing of pole 156 labour for concreting of rail / hbeam supports @0.65 cmt.per pole including muffing of pole 157 concreting of stay ( 20 mm / 25 mm ) @ 0.3 cmt. per stay 158 labour forconcreting of stay ( 20 mm / 25 mm ) @ 0.3 cmt. per stay 159 gst 18% 160 task name: 33kv four h beam 13 mtr long ( 2 no. ) 161 33 kv composite polymer disc insulators 162 33 kv strain hardware ( t&c type ) fittings 163 33 kv, 10 kn pin composite polymer insulator 164 erection cost for33 kv, 10 kn pin composite polymer insulator 165 aluminium paint 166 erection cost of aluminium paint 167 anti climbing device ( barbed wire ) gs 2.24 mm dia ( 14 swg ) 168 erection cost for anti climbing device ( barbed wire ) gs 2.24 mm dia ( 14 swg ) 169 bracing / support angle of 65x65x6 mm for 5 ( 1.5 mtr ) centre dp 170 fixing of bracing / support angle of 65x65x6 mm for 5 ( 1.5 mtr ) centre dp 171 concreting of rail / hbeam supports @0.65 cmt.per pole including muffing of pole 172 labour for concreting of rail / hbeam supports @0.65 cmt.per pole including muffing of pole 173 concreting of stay ( 20 mm / 25 mm ) @ 0.3 cmt. per stay 174 labour forconcreting of stay ( 20 mm / 25 mm ) @ 0.3 cmt. per stay 175 d.c. cross arms 5 centre to center ( 100x50x6 mm ) channel 176 fixing of d.c. cross arms 5 centre to center ( 100x50x6 mm ) channel 177 danger boards enamelled 33 kv 178 erection cost of danger boards enamelled 33 kv 179 earthing coil of 115 turns of 50 mm.dia and 2.5 mtr lead of 4.0 mm g.i wire 180 h beams 152 x 152 mm., 37.1 kg. / meter 13 meter. long 181 erection cost of h beams 152 x 152 mm., 37.1 kg. / meter 13 meter. long 182 h.beam clamps 65x8mm flat 183 h.beam back clamps 65x8mm flat ( in numbers ) 184 m.s.nuts and bolts 185 ms strain plate 65x8mm 250mm long 186 red oxide paint 187 erection cost for red oxide paint 188 stay gi wire 7 / 4.00 mm. ( 7 / 8 swg ) 189 stone block / pre cast block for base pedding ( 450x450x75mm ) 190 gst 18% 191 task name: 11 kv line on pcc pole ( 0.5 km ) 192 140 kg., 8.0 mtrs. long pcc pole 193 erection cost for 140 kg., 8.0 mtrs. long pcc pole 194 trans .for 140 kg., 8.0 mtrs. long pcc pole ( 0 01 km ) 195 stay wire 7 / 3.15 mm. ( 7 / 10 swg ) 196 clamp for 140 kg pcc pole ms flat 50x6 mm 197 stay insulators 90x65mm 198 back filling of poles with boulders.1 199 g.i. wires 4.0 mm. ( 8 swg ) 1 200 stone block / pre cast block for base pedding ( 450x450x75mm ) 201 concreting of stay ( 16 mm / 12 mm ) @ 0.2 cmt. per stay 202 erection cost of concreting of stay ( 16 mm / 12 mm ) @ 0.2 cmt. per stay 203 red oxide paint 204 erection cost for red oxide paint 205 aluminium paint 206 erection cost of aluminium paint 207 anti climbing device ( barbed wire ) gs 2.24 mm dia ( 14 swg ) 208 erection cost of anti climbing device ( barbed wire ) gs 2.24 mm dia ( 14 swg ) 209 danger boards enamelled 11 kv 210 erection cost of danger boards enamelled 11 kv 211 aluminium binding wire and tape 212 m.s.nuts and bolts 213 back clamp for 140 kg pcc pole ms flat 50x6 mm 214 earthing coil of 115 turns of 50 mm.dia and 2.5 mtr lead of 4.0 mm g.i wire 215 11 kv polymer pin insulator 216 erection cost of11 kv polymer pin insulator 217 aaac rabbit conductor 0.05 sq. inch. ( 55 sq.mm. al.eq. ) 218 erection cost of aaac rabbit conductor 0.05 sq. inch. ( 55 sq.mm. al.eq. ) ( 03 no. conductor ) 219 jointing sleeves suitable for rabbit ( 55sq.mm.al. eq. ) aaac conductor 220 stay set complete without stay wire 16 mm. ( painted ) 221 erection cost ofstay set complete without stay wire 16 mm. ( painted ) 222 11 kv composite polymer disc insulators 223 11 kv single pole cut point fitting 100x50x6 mm channel 224 fixing of 11 kv single pole cut point fitting 100x50x6 mm channel 225 11 kv strain hardware ( t&c type ) fittings 226 11 kv top clamp 65x65x6 mm. angle type 227 11 kv v cross arm 65x65x6 mm. angle type 228 fixing for 11 kv v cross arm with top clamp 229 gst 18% 230 task name: 11 kv tp on pcc pole ( 3 no. ) 231 11 kv composite polymer disc insulators 232 11 kv polymer pin insulator 233 erection cost of11 kv polymer pin insulator 234 11 kv strain hardware ( t&c type ) fittings 235 140 kg., 8.0 mtrs. long pcc pole 236 erection cost for 140 kg., 8.0 mtrs. long pcc pole 237 trans .for 140 kg., 8.0 mtrs. long pcc pole ( 0 01 km ) 238 aluminium paint 239 erection cost of aluminium paint 240 anti climbing device ( barbed wire ) gs 2.24 mm dia ( 14 swg ) 241 erection of anti climbing device ( barbed wire ) gs 2.24 mm dia ( 14 swg ) 242 back clamp for 140 kg pcc pole ms flat 50x6 mm 243 clamp for 140 kg pcc pole ms flat 50x6 mm 244 concreting of stay ( 16 mm / 12 mm ) @ 0.2 cmt. per stay 245 erection cost of concreting of stay ( 16 mm / 12 mm ) @ 0.2 cmt. per stay 246 danger boards enamelled 11 kv 247 erection cost of danger boards enamelled 11 kv 248 earthing coil of 115 turns of 50 mm.dia and 2.5 mtr lead of 4.0 mm g.i wire 249 earthing for pcc pole 4.00 mm 8 swg g.i wire 0.8 kg, per pole 250 m.s.nuts and bolts 251 ms strain plate 65x8mm 250mm long 252 red oxide paint 253 erection cost for red oxide paint 254 stay wire 7 / 3.15 mm. ( 7 / 10 swg ) 255 stay set complete without stay wire 16 mm. ( painted ) 256 erection cost ofstay set complete without stay wire 16 mm. ( painted ) 257 stone block / pre cast block for base pedding ( 450x450x75mm ) 258 bracing / support angle of 65x65x6 mm for 8 feet ( 2.45 mtr ) centre dp 259 fixing of bracing / support angle of 65x65x6 mm for 5 ( 1.5 mtr ) centre dp 260 concreting of pcc pole @ 0.30 cmt per pole for base padding for dp / tp etc 261 erection cost for concreting of pcc pole @ 0.30 cmt per pole for base padding for dp / tp etc 262 d.c. cross arms 8 channel ( 100x50x6mm ) 263 fixing of d.c. cross arms 8 channel ( 100x50x6mm ) 264 gst 18%...

Madhya Pradesh Madhya Kshetra Vidyut Vitaran Company Limited - Madhya Pradesh

34068661 estimate for supply arrangement to separate 33 / 11 kv s / s banmore yard from 132kv s / s banmore under banmore d / c of ( o&m ) morena ii dn.under sstd scheme 2022 23, erp no 817048 1 task name: proposed vcb & other material 2 33 kv composite polymer ab switch 3 erection cost of 33 kv composite polymer ab switch 4 33 kv control & relay panel with static relay for transformer protection 5 handling and installetion of control pennel including stand of suitable size 6 33 kv cts. ( out door oil filled type ) 200 100 / 5 amps 7 handling and installetion of 33 kv cts. with earthing arranements 8 33 kv vcb, outdoor porcelain clad type with complete structure and accessories 9 erection cost of33 kv vcb, outdoor porcelain clad type with complete structure and accessories 10 aaac dog conductor 0.10 sq. inch ( 100 sq.mm. al.eq. ) 11 striging of aaac dog conductor 0.10 sq. inch ( 100 sq.mm. al.eq. ) ( 03 no. span ) 12 concreting of foundation of vcb ( 1:3:6 ) @ 3.5 cmt per vcb plinth 13 erection cost of concreting of foundation of vcb ( 1:3:6 ) @ 3.5 cmt per vcb plinth 14 labour for pit diging for vcb size ( 3x2x0.3 ) =3.6 mtr. 15 copper control cable 2 core. 2.5 sq.mm. ( unarmoured ) 16 erection cost ofcopper control cable 2 core. 2.5 sq.mm. ( unarmoured ) 17 copper control cable 4 core. 2.5 sq.mm. ( unarmoured ) 18 erection cost copper control cable 4 core. 2.5 sq.mm. ( unarmoured ) 19 copper control cable 8 core. 2.5 sq.mm. ( unarmoured ) 20 erection cost copper control cable 8 core. 2.5 sq.mm. ( unarmoured ) 21 m s channel 75x40mm 22 gst 18% 23 task name: 11 kv dp structure on pcc pole / h beam 13 mtr long 24 33 kv composite polymer disc insulators 25 33 kv strain hardware ( t&c type ) fittings 26 33 kv, 10 kn pin composite polymer insulator 27 aluminium paint 28 erection cost of aluminium paint 29 anti climbing device ( barbed wire ) gs 2.24 mm dia ( 14 swg ) 30 erection cost for anti climbing device ( barbed wire ) gs 2.24 mm dia ( 14 swg ) 31 bracing / support angle of 65x65x6 mm for 5 ( 1.5 mtr ) centre dp 32 erection cost fo bracing / support angle of 65x65x6 mm for 5 ( 1.5 mtr ) centre dp 33 concreting of rail / hbeam supports @0.65 cmt.per pole including muffing of pole 34 labour for concreting of rail / hbeam supports @0.65 cmt.per pole including muffing of pole 35 concreting of stay ( 20 mm / 25 mm ) @ 0.3 cmt. per stay 36 labour forconcreting of stay ( 20 mm / 25 mm ) @ 0.3 cmt. per stay 37 d.c. cross arms 5 centre to center ( 100x50x6 mm ) channel 38 fixing of d.c. cross arms 5 centre to center ( 100x50x6 mm ) channel 39 danger boards enamelled 33 kv 40 erection cost of danger boards enamelled 33 kv 41 earthing coil of 115 turns of 50 mm.dia and 2.5 mtr lead of 4.0 mm g.i wire 42 h.beam back clamps 65x8mm flat 43 m.s.nuts and bolts 44 red oxide paint 45 erection of red oxide paint 46 stay set without stay wire 20 mm. ( painted ) 47 erection cost of stay set without stay wire 20 mm. ( painted ) 48 stay wire 7 / 4.00 mm. ( 7 / 8 swg ) 49 gst 18% 50 task name: proposed dp structure on 11 mtr.long h beam 51 33 kv composite polymer disc insulators 52 33 kv strain hardware ( t&c type ) fittings 53 33 kv, 10 kn pin composite polymer insulator 54 aluminium paint 55 erection cost of aluminium paint 56 anti climbing device ( barbed wire ) gs 2.24 mm dia ( 14 swg ) 57 erection cost for anti climbing device ( barbed wire ) gs 2.24 mm dia ( 14 swg ) 58 back clamp b type for rail pole 59 bracing / support angle of 65x65x6 mm for 5 ( 1.5 mtr ) centre dp 60 erection cost fo bracing / support angle of 65x65x6 mm for 5 ( 1.5 mtr ) centre dp 61 concreting of stay ( 20 mm / 25 mm ) @ 0.3 cmt. per stay 62 labour forconcreting of stay ( 20 mm / 25 mm ) @ 0.3 cmt. per stay 63 concreting of structures & foundation ( 1:3:6 ) 64 labour forconcreting ofconcreting of structures & foundation ( 1:3:6 ) 65 d.c. cross arms 5 centre to center ( 100x50x6 mm ) channel 66 fixing of d.c. cross arms 5 centre to center ( 100x50x6 mm ) channel 67 danger boards enamelled 33 kv 68 erection cost of danger boards enamelled 33 kv 69 earthing coil of 115 turns of 50 mm.dia and 2.5 mtr lead of 4.0 mm g.i wire 70 h beams 152 x 152 mm., 37.1 kg. / meter 11 meter. long 71 erection cost ofh beams 152 x 152 mm., 37.1 kg. / meter 11 meter. long 72 m.s.nuts and bolts 73 red oxide paint 74 erection cost for red oxide paint 75 stay clamp a type ( for rails ) 65x8mm flat 76 stay set without stay wire 20 mm. ( painted ) 77 erection cost of stay set without stay wire 20 mm. ( painted ) 78 stay wire 7 / 4.00 mm. ( 7 / 8 swg ) 79 gst 18%...

National Thermal Power Corporation Limited - Madhya Pradesh

33984644 procurement of siemens make lt spares at ntpc vindhyachal procurement of siemens make lt spares at ntpc vindhyachal , bmr 32 50a, siemens 3ua58 00 2fz1 , control relay for erv controller , micro processor based over load relay , 1.6 2.5amp over load relay siemens make , rely o / l63 630a:m / prsr basd 3rb2283 4aa1 , off delay timer;5 100s, 110v ac siemens , rely o / l:50 200a:siemns 3rb21 micrprcsr , o / l relay: 10 40a, 3rb3123 4vb0 , o / l relay: 3 12a, 3rb3123 4sb0 , bim o / l;57 70a;siemens 3ua58002vz2 , powcont, 75a, coil220vdc, 3tf4822, siemens , power contactor 3p 415v 32amp, siemens , siemenscontactor, type:3th8031 obm4 , 15person lift:push button , powercontactor, 3tf4602 0ab0za01, 45a, 24ac , power contactor, 3tf3500 ab0, cv 24vac, 38a , power contactor, type:3tf32000 ab0, 24ac , pc 300a 3tf55 siemens cv:240vac, 2no+2nc , pwrcontr:240vac 100a seimens;3ta13 , siemens airbreakcontactor3tf4322oauo , siemens contactor, 240v ac coil, 3tf33 , power contactor, 3tf30100 ab0, 9a, cv 24ac , powr contr: 3p415vac:230vac:225a:siemens , powr contr: 3p415vac:230vac:185a:siemens , power contactor 3 p cv 230v, 32a siemens , contactor 3tf56, 110v / 50hz, 400a, 2no+2nc , 3tf4222 0a, 110a, 240v / 50hz, 2no+2nc, siemns , power contactor 3 p cv 110v, 70a siemens , siemensmake contactor 3tf 47 02 0a , powr contr:3p415vac:110vac:40a:siemens , powr contr:3p415vac:110vac:32a:siemens , siemens contactor type 3tf46, 45a , air break contactor, 3tf4702 0ab0za01 , power contactor, 3tf35 oo oabo, 24vac coil , pc 16a, cv:24vac.siemens make , thermalo / lrly3ua58 00 2vz1, 57 70, siemens , thermal o / l relay, 50 63a, 3ua58 00 2pz1 , 40 57amp over load relay siemens make , positioner sipart ps2:6dr5120 0nn00 0aa4 , pneu.positnr: 6dr5110 0nn00 0aa0; siemns , thermal overload relay 1 1.6 a siemens , auxcontactblock3tx40, 10 2a, 1no, siemens , aux contr dccv:110vdc:4no:siemens , aux contactor for dc coil 240v siemens , time s / w:on dely siemens 3rp1525 1bw30 , aux contactor 3th8280 coil : 24vdc , timer:siemens make, modle 3rp1511 1aq30 , pwr contactor 415v50a240vac coil siemens , power supply module: sitop, 24vdc;siemens , acb: 3pole, electricly.oper, 2500a, siemens , acb: 3pole, electricaly oper, 800a, siemens , 3th8022 0a, 6a, 240v50hz, 2no+2nc, siemens , power contactor 3p 415v ac 25 a siemen , aux.contactor, siemens, ( 3tb41 ) 415 vac, 12a , aux contactorfor ac coil 3no+1nc , aux contactor 415vac coil, 4no, 3th30 , sfu3kl41.30 1yaco 400 a siemens make , 3th30 aux contactor ac coil 230v 2no+2nc , aux. cont. 3th8253 oafo , auxiliary contactor 3th 30 40 oauo , auxcon ( lt ) coil240vacsiemens 3th8022 0a, , powr contr:siemens:3tf49 22 0a bo za01 , aux contactor, 24v dc2no2nc 3th3022 obb4 , aux cont 10a, cv:220vdc 2no+2nc, siemens , bmr range 32 40a, siemens 3ua55 00 2r , o / c relay power cont 28 40 a lr1 d32355 , contactor type;3th3040 0afo , relay therml o / l 25 36a, siemens 3ua55 , relay therml o / l 20 32a, siemens 3ua55 , bmr 16 25amp, 3ua52 00 2c siemens make , thermal o load relay a 16 25 a 3ua , thrm overlod rely amp 16 25 asiemens , rely th o / l:13 19a:siemens , thermalo / l rly 3ua52002b, siemens make , relay thermal o / l: 9 12.5a, siemens , bmr 3ua 1928 oap, 8 12a, siemens make , thrm overlod rely amp 6.3 10 asiemens , 110vdc, cont siemens, 3th3031 0bf4 , simatic s7 plc, profibus connector , bmr 2 3.2a, siemens 3ua5000 1d , powr contr:3p415vac:230vac:siemens:3tf30 , bmr 1.25 2a, siemens 3ua5000 1b , thermalo / lrly3ua5000 ib, 1.25a 2asiemens , powr contr:2p440vac:230vac:siemens:3tf55 , plc processor model: s7 1200; siemens , o / l relay 1.0 1.6 a type:3ua5000 1a , adaptor plate for 3ua5500.type 3ux1425. , contactsfor 3tf56 6fixed& 3 moving...

West Central Railway - Madhya Pradesh

33841119 supply of electromagnetic type inter trip relay of control and relay panel .supply of electromagnetic type inter trip relay of control and relay panel ., supply of electromagnetic type inter trip relay of control and relay panel for 25 kv ac tss as per latest rdso specification no. ti / spc / psi / protect / 6071 with a & c slip no. 1 make ashida ( type avajh13 ) or any other make suitable for control & relay panel of ashida make provided in jabalpur division of west central railway. firm should integrate the item with the existing system....

Madhya Pradesh Power Generating Company Limited - Madhya Pradesh

33840531 procurement of spares of schenck process make gravimetric feeder system installed at 2x660mw, sstpp, mppgcl, dongalia procurement of spares of schenck process make gravimetric feeder system installed at 2x660mw, sstpp, mppgcl, dongalia , calibration kit ( a21306 1 ) calibrationprobeassemblies ( 2 n0. ) , probe interconnecting cables ( 4 no. ) , and retro reflective tape ( 8 no ) , zero speed sensor ( namur ) typeinductive sensor sizemetal thread m8x1 supply voltage5…30v dc real sensing range2mm cable length2m ( not integral type ) switching frequency0 200hz protectionip67 , 2 position sel.switchv004848.b06 , indication lamp, redv000867.b06 , input reactorv003971.b06 , output reactorv000821.b06 , disconnector switchv000823.b06 , fuse links din standard 32av000874.b06 , power line monitor 3phv002879.b06 , 4 20m a dual channel modulev003924.b06 , current sensing relayv002880.b06 , power supply 24 vdc 30wv004544.b06 , swc module ( diode ) v002984.b06 , control relay 4 nov004798.b06 , control relay 2 no 2 ncv000833.b06 , control relay 3 no 1ncv000834.b06 , surge suppressor cont. rlyv004425.b06 , aux front mounted 2no+2ncv003549.b06 , aux front mounted 1no+1ncv003445.b06 , glass fuse 1av000813.b06 , current / voltage trip amplifierv000880.b06 , power contactor relay 9av000841.b06 , zener barrier z961.hv004545.b06 , zener barrier z966.hv004546.b06 , trip contact for mpcbv004850.b06 , motor protection ckt breakerv004849.b06 , lat. aux. contact for mpcbv004851.b06 , socket for plug in relayv000882.b06 , plug in relay 4 c / ov000843.b06 , rc circuit plug in relayv004540.b06 , transformer 500vav005153.b06 , control relay 2no 2nc 23ovv003108.b06 , indication lamp redv002619.b06 , indication lamp amberv001165.b06 , push button blackv004797.b06 , selector switch 2 pos. 1nov004848.b06 , selector switch 3 pos. 3 nov002579.b06 , selector switch 4 pos. 3 no.v004856.b06 , coal feed rate indicatorv003594.b06 , coal flow totalizerv003593.b06 , assembly weighing modulectype: strain gauge, voltage: 12 vdc; temp range: 54 ç to 149 ç ; i / p resistance : 350 ohm +10%; o / p resistance : 350 ohm + / 1% ; cable : 4.5 mtr ip:65 c19387 005...

Madhya Pradesh Power Generating Company Limited - Madhya Pradesh

33754427 procurement of various protection relays installed at switchgear of chp iv and vacuum interrupter vg4, epoxy housing body and spring charging gear assembly for 6.6 kv vacuum circuit breaker for emd iv, stps, mppgcl, sarni. procurement of various protection relays installed at switchgear of chp iv and vacuum interrupter vg4, epoxy housing body and spring charging gear assembly for 6.6 kv vacuum circuit breaker for emd iv, stps, mppgcl, sarni. , various protection relays installed at switchgear of chp iv , micom p220, cortec code : p220c00m11100 0.002 1 ion 1 / 5a, vx 130 250 vdc / 110 250 vac, 50 / 60 hz. , micom p127, cortec code : p127 ba0z112ca1, vx 24 250 vdc / 24 240 vac, 50 / 60 hz , micom p921, cortec code : p9210asz112bb1, un 57 130 vac, vx 24 250 vdc / 24 – 240 ac, 50 / 60 hz. , micom p122, cortec code : p122b00 z112cc1, 0.01 8 ion 1 / 5a vx 24 250 vdc / 24 250 vac, 50 / 60hz. , micom p122, model =b, vx 60 240v ac / dc, 50 / 60hz, in = 0.375 1.5a, ion = 1 / 5a ( 0.01 1a ) , micom p111, model =l, vx 60 240v ac / dc, 50 60hz, in = 1 / 5a ( 0.01 2a ) , trip circuit supervision relay, type = vax, model = vax31zg8075bch, vx = 220 250vdc. , tripping relay, type = vaj, model = vajhm23zg1004bba, vx = 220 250vdc , control relay, type = vajc model = vajc11zf1004aba, vx = 220 250vdc. , instantaneous under voltage relay, type = vag, model = vag21zg8002adch, vn=110vac, vs = 27.5 66vac, vx 220vdc. , instantaneous earth fault relay, type = cag, model = cag14af14a ct sec.=1a, 50hz. , check synchronizing relay, type = ske, model = ske11bf8013bch, rated voltage = v1, v2 : 63.5 / 110v, 50hz, aux. voltage = 220 230vdc. , check synchronizing relay, type = skd, model = skd11bf8003bch, rated voltage = v1, v2 : 63.5 / 110v, 50hz, aux. voltage = 220 230vdc. , auxiliary relay, type = vaa. model = vaa33zg8314fch, vx 220 250 vdc , tripping relay, model = vaj. model : vajh13yf1001aba, vx=220 250 vdc. , fuse failure relay, type = vapm, model = vapm31af21a, vn = 110, 50hz. , instantaneous earth fault relay, type=cag. model = cag14af12a, ct sec. = 1a, 50hz. , vacuum interrupter –vg4, epoxy housing body and spring charging gear assembly for 6.6 kv vacuum circuit breaker for emd iv , vacuum interrupter – vg4, 00 2ff 045043 for hwx type vacuum , epoxy housing , resin cast vacuum interrupter for hwx typevacuum circuit breaker , spring charging gear assembly...

Madhya Pradesh Power Generating Company Limited - Madhya Pradesh

33660812 procurement of spares and servicing of mellcon make blower heat reactivated air dryer installed at ash handling plant of unit no. 5, 1x500mw, at sgtps, mppgcl, birsinghpur. 1 purchase portion ( as per tender schedule ) 2 temperature indicator control supply voltage: 110vac 3 blind temperature control supply voltage: 110vac 4 automatic drain solenoid 15 mm or ½”, 110v ac 5 safety valve 25 mm or 1” connection, ref: 300 psi 6 safety valve for prefilter and after filter 15 mm or ½” connection 7 blower heater nrv ( flow regulating valve ) 8 air dryer desiccant or adsorbent activated silica gel for ad a & ad b 9 prefilter and after filter cartridge 10 sequence timer, cam type timer, 7 cam & 16 hours 11 delay timer supply voltage: 110vac 12 control relay supply voltage: 110vac 13 hooter supply voltage: 110vac 14 heater element 15 r.t.d. sensor for tic 16 r.t.d. sensor for btc 17 work portion ( as per tender schedule ) 18 deputation of service engineer for commissioning of spares and complete servicing of 02 nos. blower heat reactivated type air dryer....

Indira Gandhi Rashtriya Manav Sangrahalaya - Madhya Pradesh

33532214 e tender for execution of work with material under new bay for 33 kv incomming line under creation of capital assets ( cca ) of indira gandhi rashtriya manav sangrahalaya ( igrms ) , bhopal 16 1 supply of support for overhead line h beam of i.s. standard including drilling of required hole etc. complete as required. h beam 152x152mm, std weight 37.1 kg / mtr 2 supplying and drawing all aluminium alloy conductor ( aaac ) of approved make conforming to is 398 1979 pt. iv, including binding at existing insulator, jointing, jumpering, tearing off, connecting etc. as required including clearing of obstacles ( if any ) aaac 0.1 sq inch ( 100 sq mm al. eq. ) ( dog ) 3 erection of rs joist pole / h beam / steel tubular / steel rail pole of length 7 metres but not exceeding 10 metres in cement concrete 1:3:6 ( 1 cement : 3 core sand: 6 graded stone aggregate 40mm nominal size ) base, foundation, muffing including excavation and back refilling etc. as required. 4 supply, fabrication and erection of angle / channel / flat iron fitting for overhead line & sub station etc such as d bracket, cross arms, top clamp, v cross arms, back / support clamp or other similar work etc. including nut bolts of required size, making holes, fabrication, welding, cutting, etc. and painting with one coat of red oxide paint & two coat of aluminium paint as required as per specification 5 supplying and erection of 33kv ( 10 kn ) polymer pin insulator complete with long steel head g.i. pin, nut, washer etc. as required 6 supplying and erection of 33kv ( 45 kn ) polymer disc insulators for 33kv overhead lines with galvanized insulator fittings, ball and socket type, and complete with galvanized strain clamp, bolts, nuts, washers etc. as required 7 supplying and erection of single piece nonlinear resistor polymer type lightning arrestor ( set of 3 nos ) for 3 wire, 33kv overhead lines / sub station with rated voltage of 27kv ( rms ) with a nominal discharge current rating of 10 ka and complete with galvanized clamping arrangement, g.i. bolts, nuts, washer etc. as required 8 supply & fixing anti climbing device with 2 ply g.i. barbed wire 1 kg. per pole complete as per mpmkvvco. specification. 9 supplying and fixing 33 / 11 / 0.4 kv enamel coated danger board size 200x250mm with clamp on existing ht / lt structure / poles. 10 supplying installing, testing & commissioning of outdoor h.t., ab switch assembly set gang operated with brass contact parts, including required gi pipe operating rod, handle & locking arrangement on on off position conforming to is complete with required material and installing on existing dp structure to complete the job as required as per specification. ( set of 3 nos. ) 33 kv, 600 amp 11 supply, laying and fixing of g.i. earth coil of 4mm dia g.i. wire having 120 turns of nearly 50mm dia. and 3 mt. long tail in existing pit duly earthed with pole etc complete as required as per specification 12 supply & fixing fencing of chain link mesh 100 x 100 mm, 12 swg gi wire for for d.p. structure electric sub station switch yard including single post of angle iron size 50x50x5mm, 2.5 mt long should be provided upto 2.00 mt. apart or as required. the panel frame with required angle iron / flat iron members / cross members including mesh welded in frame panel shall be erected between the posts. the angle iron post shall be erected in cement concrete m 15 ( 1:2:4 ) ( 20 mm graded metal ) foundation, including excavation of pit and refilling the same. the fencing shall be provided with one entrance gate including locking arrangement as required as per specification. the height of fencing shall be 2 mt. above ground level. fencing shall be painted with required shade. 13 designing and construction of pedestal ( plinth ) for transformer of desired size including excavation in hard rock / soft rock, base concrete m 7.5 ( 1:4:8 ) , 20mm metal and pedestal of rcc m 15 ( 1:2:4 ) including required tar steel reinforcement for required height as per ie rules from base concrete including shuttering and finishing with 10mm thick plaster in cement mortar 1:3 curing & white washing etc. complete as per specifications. 14 collection and spreading of metal dust, murum and 40mm graded hard metal in sub station yard or as required as mentioned metal 40 mm 15 supply and filling of new transformer oil of desired break down value for topping as reqd. 16 filtration of transformer oil for 33 / 0.4 kv, 11 / 0.4 kv 3 phase 50 cycle oil immersed, naturally cooled, distribution transformer upto desired break down value. 17 supplying, installation, testing and commissioning of triple pole outdoor type 11kv / 33kv vacuum circuit breaker with outdoor control & relay panel with numerical static relay for feeder protection ( 1f ) . the installation of vcb shall be carried out in accordance with is: 3072. the vcb shall be mounted on suitable size duly painted ms channel / angle iron structure with nut bolts and washer. the structure shall be fixed on existing cement concrete foundation. the complete work should be done as per is specification. 33 kv 1250a vcb 18 supplying, installation, testing and commissioning of indoor control relay panel shall consisting of ammeter, voltmeter, selector switch, auxiliary relays for anti pumping device, trip and alarm of buchholz relay, oil and winding temperature circuit, electronic hooter, 230 v ac to 110 v dc power pack with charging equipment for closing, tripping and indication, triple pole idmtl two o / c and one e / f delay with current setting range 50 200% and 10 50%, push button high speed trip relay etc. complete as per is specification. 19 supplying & installing g.i. pipe for protection of underground cable fixed on wall / support / in trench / fixed between two rigid existing support of wall / beam for erection of ceiling fan / down rod for stiff pendent for light luminaries / fan / protective earthing, lightening conductor down strip / overhead service line / for submersible cable or centrifugal pump for water supply with necessary iron clamp coupler, bend, tee, elbow, nuts and bolts etc. complete in an approved manner as required to complete excluding cost of excavation / dismantling & other finished masonry item complete. for b class pipe isi marked ( is 1161 68 ) 100.00 mm 20 supply of approved high tension xlpe cable ( conforming is 7098 / ii / 85 ) as per isi standard core armoured with alu. solid / stranded conductor isi marked as required 3 core xlpe cable 33 kv grade 240 sq mm 21 providing & making cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 33 kv / 11 3 core xlpe alum. conductor cable as required per specification and as per accepted standard including connection testing complete. heat shrinkable jointing kit 33 kv xlpe cable o.d. termination 3 x 240 400 sq mm...

Northern Coalfields Limited - Madhya Pradesh

33428143 bids are invited for shifting of west sub station of jayant project 33kv 1250a isolator pole off load isolator horizontal cut with earthing switch 6600 v 1250 a triple pole off load isolator horizontal type complete set 33kv station type current transformer . the detailed technical specifications mentioned in boq sl no 3 of annexure xiv 33kv 110v pt burden 100va 01 set of 03 nos overhauling of 33kv 1250a sf6 circuit breaker with control relay panel providing lightning arrestor 30kv 10ka station type 01 set of 03 nos overhauling 6600 v 1250amp vcb outdoor type with control relay panel the detailed technical specifications mentioned in boq sl no 7 of annexure xiv overhauling 6600 v 1250amp vcb outdoor type with control relay panel the detailed technical specifications mentioned in boq sl no 8 of annexure xiv 110v battery battery dc ni cd acid maintenance free battery 200ah 55 nos cells each cell 02 volt 110 volt battery charger 3phase 415 v input and 110v dc output with float and boost charging 25amp to 35amp lighting distribution board consist of incomer mccb 250a and different rating for controlling different lighting circuits along with spares as per requirement lightening arrestor 7kv 5va station type 01 set of 03 nos 1100 v grade copper control cable the detailed technical specifications mentioned in boq sl no 13 of annexure xiv dc power distribution board consist of incomer and sufficient number of outgoing feeder the detailed technical specifications mentioned in boq sl no 14 of annexure xiv supply of bus bar the detailed technical specifications mentioned in boq sl no 15 of annexure xiv designing laying erection testing and commissioning of earthing arrangement the detailed technical specifications mentioned in boq sl no 16 of annexure xiv structural steel work with new mild steel supply fabrication erection and painting work in the scope of bidder as per boq sl no 17 of nit annexure xiv supply of misc items nut bolt clamps pad gi strip ect erection of 13 or 16 mtr pole for lighting arrangement erection and commissioning for item sl no 1 3 4 5 6 7 8 9 10 11 12 13 14 and 15 fabrication erection and painting of steel structure and commissioning dismantling shifting erection and commissioning of bus bar with structure insulators etc as per requirement dismantling shifting erection and commissioning of 33kv 1250a isolator with or without earth switch as per requirement dismantling shifting erection and commissioning of 33kv 10ka lightning arrestor as per requirement dismantling shifting erection and commissioning of 33kv grade current transformer the detailed technical specifications mentioned in boq sl no 25 of annexure xiv dismantling shifting erection and commissioning of 33kv pt as per requirement dismantling shifting erection and commissioning of 33kv 1250a sf6 circuit breaker with control panel and tap changer as per requirement dismantling shifting erection and commissioning of 33kv 1250a circuit breaker with control panel as per requirement dismantling shifting erection and commissioning of 10mva 33kv 6600 v transformer as per requirement dismantling shifting erection and commissioning of 6600 v isolator 1250 or 800 a as per requirement dismantling shifting erection and commissioning of 6600 v 1250a circuit breaker with control relay panel as per requirement dismantling shifting erection and commissioning of 6600 v 1250a or 630a circuit breaker with control relay panel as per requirement dismantling shifting erection and commissioning of ngrs as per requirement erection of armoured copper control cable. the detailed technical specifications mentioned in boq sl no 34 of annexure xiv earth work in excavation by mechanical means hydraulic excavator or manual means in foundation trenches or drains the detailed technical specifications mentioned in boq sl no 35 of annexure xiv excavation work by mechanical means hydraulic excavator or manual means in foundation trenches or drains the detailed technical specifications mentioned in boq sl no 36 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering the detailed technical specifications mentioned in boq sl no 37 of annexure xiv brick work with non modular fly ash lime bricks the detailed technical specifications mentioned in boq sl no 38 of annexure xiv brickwork with non modular falg bricks the detailed technical specifications mentioned in boq sl no 39 of annexure xiv providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering shuttering finishing and reinforcement the detailed technical specifications mentioned in boq sl no 40 of annexure xiv reinforced cement concrete work in walls any thickness including attached pilasters etc the detailed technical specifications mentioned in boq sl no 41 of annexure xiv reinforced cement concrete work in beams suspended floors roofs having slope the detailed technical specifications mentioned in boq sl no 42 of annexure xiv providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering the detailed technical specifications mentioned in boq sl no 43 of annexure xiv centering and shuttering including strutting, propping etc and removal of form for the detailed technical specifications mentioned in boq sl no 44 of annexure xiv centering and shuttering including strutting propping etc and removal of form for columns pillars piers abutments posts and struts centering and shuttering including strutting propping etc and removal of form for lintels beams plinth beams girders bressumers and cantilevers the detailed technical specifications mentioned in boq sl no 46 of annexure xiv centering and shuttering including strutting propping etc and removal of form for suspended floors roofs landings balconies and access platform centering and shuttering including strutting propping etc and removal of form for weather shade chajjas corbels etc including edges centering and shuttering including strutting propping etc and removal of form for walls any thickness including attached pilasters butteresses plinth and string courses etc providing and fixing 1 mm thick ms sheet door with frame the detailed technical specifications mentioned in boq sl no 50 of annexure xiv supplying and fixing rolling shutters of approved make made of required size the detailed technical specifications mentioned in boq sl no 51 of annexure xiv providing and fixing ms grills of required pattern in frames of windows etc the detailed technical specifications mentioned in boq sl no 52 of annexure xiv structural steel work in single section fixed with or without connecting plate including cutting hoisting fixing in position and applying a priming coat of approved steel primer all complete cement concrete flooring the detailed technical specifications mentioned in boq sl no 54 of annexure xiv providing and laying vitrified tiles in different sizes the detailed technical specifications mentioned in boq sl no 55 of annexure xiv providing and laying vitrified floor tiles in different sizes thickness to be specified by the manufacturer with water absorption the detailed technical specifications mentioned in boq sl no 56 of annexure xiv providing and fixing 10 mm thick acid and or alkali resistant tiles of approved make and colour using acid and or alkali resisting mortar bedding, and joints filled with acid and or alkali resisting cement as per is the detailed technical specifications mentioned in boq sl no 57 of annexure xiv providing and fixing 10 mm thick acid and or alkali resistant tiles of approved make and colour using acid the detailed technical specifications mentioned in boq sl no 58 of annexure xiv 12 mm cement plaster of mix the detailed technical specifications mentioned in boq sl no 59 of annexure xiv 6 mm cement plaster of mix the detailed technical specifications mentioned in boq sl no 60 of annexure xiv providing and fixing ms fan clamp type i or ii of 16 mm dia ms bar bent to shape with hooked ends in rcc slabs the detailed technical specifications mentioned in boq sl no 61 of annexure xiv providing and fixing on wall face unplasticised rigid pvc rain water pipes the detailed technical specifications mentioned in boq sl no 62 of annexure xiv providing and fixing on wall face unplasticised pvc moulded fittings or accessories for unplasticised rigid pvc rain water pipes the detailed technical specifications mentioned in boq sl no 63 of annexure xiv providing and fixing on wall face unplasticised pvc moulded fittings accessories for unplasticised rigid pvc rain water pipes the detailed technical specifications mentioned in boq sl no 64 of annexure xiv providing and placing on terrace at all floor levels polyethylene water storage tank the detailed technical specifications mentioned in boq sl no 65 of annexure xiv finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade the detailed technical specifications mentioned in boq sl no 66 of annexure xiv distempering with oil bound washable distemper of approved brand and manufacture to give an even shade the detailed technical specifications mentioned in boq sl no 67 of annexure xiv providing and fixing water closet squatting pan indian type wc pan with 100 mm sand cast iron p or s trap 10 litre low level white pvc flushing cistern including flush pipe the detailed technical specifications mentioned in boq sl no 68 of annexure xiv providing and fixing wash basin with ci brackets 15 mm ptmt pillar cock 32 mm ptmt waste coupling of standard pattern including painting of fittings and brackets the detailed technical specifications mentioned in boq sl no 69 of annexure xiv providing and fixing gi pipes complete with gi fittings and clamps the detailed technical specifications mentioned in boq sl no 70 of annexure xiv providing and fixing gi pipes complete with gi fittings and clamps the detailed technical specifications mentioned in boq sl no 71 of annexure xiv providing and fixing ptmt bib cock of approved quality and colour the detailed technical specifications mentioned in boq sl no 72 of annexure xiv steel reinforcement for rcc work including straightening cutting bending placing in position and binding all complete above plinth level the detailed technical specifications mentioned in boq sl no 73 of annexure xiv providing hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses bands copings the detailed technical specifications mentioned in boq sl no 74 of annexure xiv making soak pit the detailed technical specifications mentioned in boq sl no 75 of annexure xiv providing and fixing isi marked oxidised ms sliding door bolts with nuts and screws etc complete the detailed technical specifications mentioned in boq sl no 76 of annexure xiv providing and fixing isi marked oxidised ms tower bolt black finish barrel type with necessary screws the detailed technical specifications mentioned in boq sl no 77 of annexure xiv filling available excavated earth excluding rock in trenches plinth sides of foundations etc in layers not exceeding 20cm in depth the detailed technical specifications mentioned in boq sl no 78 of annexure xiv 12 mm cement plaster finished with a floating coat the detailed technical specifications mentioned in boq sl no 79 of annexure xiv painting with synthetic enamel paint of approved brand and manufacture to give an even shade two or more coats on new work the detailed technical specifications mentioned in boq sl no 80 of annexure xiv providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length the detailed technical specifications mentioned in boq sl no 81 of annexure xiv finishing walls with water proofing cement paint of required shade the detailed technical specifications mentioned in boq sl no 82 of annexure xiv supplying and filling in plinth with sand under floors including watering ramming consolidating and dressing complete supplying and stacking at site stone aggregate 40 mm noimnal size spreading and levelling to gradient kankar or shingle or gravel or moorum or red bajri etc providing and fixing ptmt stop cock of approved quality and colour the detailed technical specifications mentioned in boq sl no 86 of annexure xiv earthwork in excavation in overburden all operation mechanically with all lifts complete as per instruction of eic the detailed technical specifications mentioned in boq sl no 87 of annexure xiv providing and fixing soil, waste and vent pipes 100 mm dia sand cast iron sands pipe as per is 1729 providing and filling the joints with spun yarn cement slurry and cement mortar the detailed technical specifications mentioned in boq sl no 89 of annexure xiv providing and fixing ms holder bat clamps of approved design to sand cast iron or cast iron spun pipe embedded in and including cement concrete blocks the detailed technical specifications mentioned in boq sl no 90 of annexure xiv providing and fixing bend of required degree with access door insertion rubber washer 3 mm thick bolts and nuts complete the detailed technical specifications mentioned in boq sl no 91 of annexure xiv providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour 450 mm long towel rail with total length of 495 mm 78 mm wide and effective height of 88 mm weighing not less than 170 gms the detailed technical specifications mentioned in boq sl no 92 of annexure xiv providing and laying cement concrete the detailed technical specifications mentioned in boq sl no 93 of annexure xiv providing and fixing beveled edge mirror of superior glass of approved quality complete with 6 mm thick hard board ground fixed to wooden cleats with cp brass screws and washers complete the detailed technical specifications mentioned in boq sl no 94 of annexure xiv providing corrugated gs sheet roofing including vertical or curved surface fixed with polymer coated j or l hooks the detailed technical specifications mentioned in boq sl no 95 of annexure xiv providing ridges or hips of width 60 cm overall width plain gs sheet fixed with polymer coated j or l hooks the detailed technical specifications mentioned in boq sl no 96 of annexure xiv providing and fixing tiled false ceiling of specified materials the detailed technical specifications mentioned in boq sl no 97 of annexure xiv extra for providing and fixing wind ties the detailed technical specifications mentioned in boq sl no 98 of annexure xiv providing and fixing mild steel round holding down bolts with nuts and washer plates complete the detailed technical specifications mentioned in boq sl no 99 of annexure xiv wiring for light or power plug the detailed technical specifications mentioned in boq sl no 100 of annexure xiv wiring for light point or fan point or exhaust fan point or call bell point the detailed technical specifications mentioned in boq sl no 101 of annexure xiv wiring for circuit or submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor the detailed technical specifications mentioned in boq sl no 102 of annexure xiv supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface or recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm the detailed technical specifications mentioned in boq sl no 103 of annexure xiv supplying and fixing following piano type switch or socket on the existing switch box or cover including connections etc as required 5 or 6 amps switch supplying and fixing following piano type switch or socket on the existing switch box or cover including connections etc as required 15 or 16 a switch supplying and fixing following piano type switch or socket on the existing switch box or cover including connections etc as required 3 pin 5 or 6 a socket outlet supplying and fixing following piano type switch or socket on the existing switch box or cover including connections etc as required 6 pin 15 or 16 a socket outlet supplying installing testing and commissioning of following capacity tpn tap off box the detailed technical specifications mentioned in boq sl no 108 of annexure xiv earthing with gi earth pipe the detailed technical specifications mentioned in boq sl no 109 of annexure xiv supplying and laying gi strip the detailed technical specifications mentioned in boq sl no 110 of annexure xiv supplying and fixing following way single pole and neutral sheet steel mcb distribution board 240 v the detailed technical specifications mentioned in boq sl no 111 of annexure xiv supplying and fixing 5 a to 32 a rating the detailed technical specifications mentioned in boq sl no 112 of annexure xiv supplying and fixing metal box of following sizes nominal size on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc the detailed technical specifications mentioned in boq sl no 113 of annexure xiv providing and fixing decorative ceiling light...

Madhya Pradesh Poorv Kshetra Vidyut Vitaran Co Ltd - Madhya Pradesh

33264356 supply of 11kv and 33kv, single and multi circuit, differential control and relay panels 11kv and 33kv, single and multi circuit, differential control and relay panels , electrical items , 11kv two feeder ( 2f ) control panels , 11kv one transformer and one feeder ( t+f ) control panels , 11kv control & relay panel for capacitor bank , 33kv transformer control panel , 33kv feeder control panel , 33kv transformer control panel with differential relay for 8mva ptr...

Madhya Pradesh Paschim Kshetra Vidhyut Vitran Corporation Limited - Madhya Pradesh

32817829 providing 1628 control & relay (c&r) panel i 11 kv c&r panel for feeder protection (2 f) ii 11 kv c&r panel for transformer protection iii 11 kv c&r panel for capacitor bank iv 33 kv c&r panel for transformer protection v 33 kv c&r panel for feeder protection vi 33 kv c&r panel for transformer with differential protection for 8 mva ptr...

Northern Coalfields Limited - Madhya Pradesh

32477021 bids are invited for item title1 ammeter 0 150900ctr 1505 part no 0201100033 item title2 ct 2crwmtrng prtctn 15055va cl1 part no 0201040054 item title3 ht hrc fuse 150a 6 desimal 6kv part no 0201160286 item title4 push button element 1no 1nc10a part no 0201060021 item title5 lamp with holder 3w220vac part no 0601020024 item title6 core balance current transformer part no 0601010035 item title7 timer elctrnc0 60s2no 2nc110vac part no 0201130032 item title8 terminal bushing for busbar support part no 0601030001 item title9 p t fuse part no 0201160342 item title10 voltmeter 0 8kv ptr 6 desimal 6kv 110v part no 0201100148 item title11 pt 3 ph 3 desimal 3kv 220v110v 500va part no 0201040011 item title12 dc pack for closing coil part no 0701040041 item title13 limit switch 3no 3nc 10a part no 0701040035 item title14 closing coil of vaccum contactor 220v part no 0701040040 item title15 vacuum interrupterbottle 3 desimal 3kv400a part no 0701020018 item title16 vacuum contactor savac4 part no 0201200004 item title17 on off isolator part no 0201080013 item title18 3ph ptntl trnsfrmr 6 desimal 6 n220110v 500va part no 0201040018 item title19 ammeter selector switch 10a3p440vac part no 0201080053 item title20 control circuit breaker 3p6a10ka part no 0201090405 item title21 aux control relay kai 3co part no 0201010062 item title22 auto transformerw tpng 1100kw 6 desimal 6kv part no 0201040316 item title23 voltmeter selector switch 10a3p440vac part no 0201080050...

Madhya Pradesh Madhya Kshetra Vidyut Vitaran Company Limited - Madhya Pradesh

32422591 estimate for 33 / 11 kv new ss at village rusalla under bhadurpur estimate for 33 / 11 kv new ss at village rusalla under bhadurpur dc under onm division mungaoli , provision : schedule a : 05 mva 33 / 11 kv s / s 01 no. schedule b: 11 kv line crossing on h beam 05 no. schedule c: 33 kv line on pcc pole 8 km schedule d: 33 kv dp structure 8 no. schedule e: 11 kv line on pcc pole 4 km schedule f: 11 kv dp structure on pcc pole schedule g: 33 kv line road crossing 2no. , lt distribution box with isolator & hrc fuse 100kva dtr ( 300a & 6 j hook ) , lt distribution box with isolator & hrc fuse 100kva dtr ( 300a & 6 j hook ) , { handling & installation of dist. box on dp, complete wiring, connecting lt cable on bushing and lt feeder ( 2 nos. ) } , xlpe 1 core unarmoured 70 sqmm aluminium 1100 v , concreting of rail / hbeam supports @ 0.65cmt. per pole including muffingof pole , labour for concreting of rail / hbeam supports @ 0.65cmt. per pole including muffingof pole , concreting of foundation of vcb ( 1:3:6 ) @ 3.5cmt per vcb plinth , labour charges for concreting of foundation of vcb ( 1:3:6 ) @ 3.5cmt per vcb plinth , concreting of structures & foundation ( 1:3:6 ) , labour charges for concreting of structures & foundation ( 1:3:6 ) , ptr fnd. cncrt:1:1.5:3 rio 5.634, 1:5:8 rio 7.545 cmt &m.s. flat / rod 324.87 kg ( as per drawing ) , rs joist 175x85mm 19.6kg / mtr. 9.3mtr. long , rs joist 175x85mm 19.6kg / mtr. 9.3mtr. long ( a ) pole pit digging in soft rock for rs joist 9.3 mtr. long [ size ( 2x4x5 ) = 40 sq. feet ] ( b ) rs joist pole errection , pvc insulated 2 core unarmoured 2.5 sqmm aluminium conductor 1100 volts , pvc insulated 4 core unarmoured 16 sqmm aluminium conductor 1100 volts , ms nuts and bolts , red oxide paint , aluminium paint , danger board enamelled 33kv , labour charges for fixing of danger board enamelled 33kv , 11 kv 1500 kvar auto switch capacitor bank including associated , handling & installation of 11 kv 1500 kvar auto switch capacitor bank including associated , fixing of 11kv bus bar per bays strining upper and lower bus bar with drop jumpers , 11kv feeder / xmer vcb complete on foundation & tightening / aligment of vcb ( 11kv vcb, outdoor porcelain clad type with complete structure and accessories ) , 11kv vcb plinth digging ( 3x2x0.6 ) =3.6 cu. mtr. , base filling by kopra in case of black cotton soil 1.92 cmt , concreting of structures & foundation ( 1:3:6 ) . , labour charges for concreting of structures & foundation ( 1:3:6 ) . , pit digging for capacitor earthing , g.i pipe 40mm dia c grade type , galvanized iron ( gi ) flat 50x6 mm , outdoor heat shrinkable jointing kit & lug for 11 kvxlpe cable 3 core 185 sqmm , outdoor heat shrinkable jointing kit & lug for 11 kvxlpe cable 3 core 185 sqmm ( cable end terminal jointing including kerosine / gas, tools and other materials required for jointing by heat shrinkable kit for 11 kv with testing and lead marking , fire extinguisher cartridge co2 10kgs , 33 / 11 kv power transformer, oftc type 5000 kva loss ( 4kw+23kw ) , crane charges for handling & installation of ptr with fitting of all radiator ( 50 km to 100km ) ( 5mva ptr ) , 33kv vcb, outdoor porcelain clad type with complete structure and accessories , 33kv feeder / xmer vcb complete on foundation & tightening / aligment of vcb ( 33kv vcb, outdoor porcelain clad type with complete structure and accessories ) , 33kv control & relay panel with static relay for transformer protection , handling & inst. of 33kv control & relay panel with static relay for transformer protection , 11kv vcb, outdoor porcelain clad type with complete structure and accessories , 11kv feeder / xmer vcb complete on foundation & tightening / aligment of vcb ( 11kv vcb, outdoor porcelain clad type with complete structure and accessories ) , 11kv c.ts. ( outdoor dry type ) 300 150 / 5amps. , 11kv c.ts. ( outdoor dry type ) 300 150 / 5amps. ( handling & installation of ct with earthing arrengment ) , 11kv control & relay panel with numerical static relay for 2feeder protection , handling & inst. of 11kv control & relay panel with numerical static relay for 2feeder protection , 30 v 200 amp hour battery set in transparent san container , 30 v 200 amp hour battery set in transparent san container ( installation of batteries on wooden rack plat form and connection each cell ( total 15 cells ) & connecting load with battery charger after clamping connection with distribution board, dc bus bar & connecting battery charger with ac switch board supply , marshelling box with 10no. connectors , 33kv, isolator 600 amp, ( turn and twist type ) , fixing of 33kv, isolator 600 amp, ( turn and twist type ) , 33kv polymer lightening arrestor gapless type ( 1set=3no. ) , labour charges for fixing of 33kv polymer lightening arrestor gapless type ( 1set=3no. ) , 9 kv gapless type ( 5 ka ) polymer lightening arrestor ( 1set= 3no. ) , labour charges for fixing of 9 kv gapless type ( 5 ka ) polymer lightening arrestor ( 1set= 3no. ) , 33kv / 110v 3ph. 4wire ct / pt 400 200 / 5amp outdoor oil immersed type, class 0.2s , installation of 33kv / 110v 3ph. 4wire ct / pt 400 200 / 5amp outdoor oil immersed type, class 0.2s , ms sheet shine board, bay indication board & ryb phase indication board , 33kv single phase pts , 33kv single phase pts. ( handling & installation of 33kv with earthing arrangment ) , 11kv single phase pts. , 11kv single phase pts. ( handling & installation of 11kv with earthing arrangment ) , 3ph 4w 3x63.5v ib=5a imax 10a, ht trivector meter, 0.5s, dlms cat a, gsw ( s / s meter ) , 3ph 4w 3x63.5v ib=5a imax 10a, ht trivector meter, 0.5s, dlms cat a, gsw ( s / s meter ) ( labour rate of installation of ht meter ( 11kv & 33kv both ) excluding me with modem complete, meter box with ttb, cabling & wiring ) , sheet metal meter box suitable for ht static travector meters with ttb , direct current distribution board ( dcdb ) 24 volts indoor floor / wall , acdb 415 v, along with three phase neutral voltmeter, three phase ammeter. , led lamp with 90 watt ( complete ) , copper control cable 8 core, 2.5sq.mm ( unarmoured ) , copper control cable 4 core, 2.5sq.mm ( unarmoured ) , copper control cable 2 core, 2.5sq.mm ( unarmoured ) , t clamp for 33kv & 11kv bus substation, , t clamp for 33kv & 11kv bus substation, ( labour charges for fixing of t clamp for 33kv & 11kv bus substation ) , bi metallic clamp for power transformer of brass flat 50x50x10mm , h beam 152x152mm, 37.1kg / mtr. 9mtr. long , h beam 152x152mm, 37.1kg / mtr. 9mtr. long ( a ) pole pit digging in soft rock h beam 9mtr. long size ( 2x4x5 ) =40 sq.feet ( b ) h beam pole errection , h beam 152x152mm, 37.1kg / mtr. 7mtr. long , h beam 152x152mm, 37.1kg / mtr. 7mtr. long ( a ) pole pit digging in soft rock h beam 7mtr. long size ( 2x4x4.5 ) = 36 sq.feet ( b ) h beam pole errection , h beam clamps 65x8mm flat , ms strain plate 65x8mm 250mm long , acsr panther conductor 0.20sq.inch for jumper , stone block / pre cast block for base pedding ( 450x450x75mm ) , h beam 152x152 mm, 37.1 kg / mtr. 11 mtr long , h beam 152x152 mm, 37.1 kg / mtr. 11 mtr long ( a ) . pit digging in soft rock for 11 mtr. h beam [ size ( 2x4x6 ) = 48 sq. feet ] ( b ) . h beam pole 11 mtr long erection , 33kv composite polymer disc insulator , 33kv strain hardware ( t&c type ) fittings , labour charges for fixing of 33 kv disc insulator with strain h / w , 33kv, 10kn pin composite polymer insulator , labour charges for fixing of 33kv, 10kn pin composite polymer insulator , 11 kv composite polymer disc insulators with strain h / w , 11kv polymer pin insulator , labour charge for fixing of 11kv polymer pin insulator , h beam back clamps 65x8mm flat ( in numbers ) , stay set without stay wire 16 mm ( painted ) , stay set without stay wire 16 mm ( painted ) ( a ) stay pit digging in soft rock ( 16 mm ) size ( 5x2.5x5 ) = 62.50 cu. feet ( b ) stay errection ( complete with binding of stay wire at eye bolt, stay insulator and anchor rod ) , stay wire 7 / 3.15mm ( 7 / 10 swg ) , earthing coil of 115 turns of 50mm dia and 2.5mtr. lead of 4.0mm g.i. wire , dtr 11 / 0.4 kv bis ee level 2 100 kva , dtr 11 / 0.4 kv bis ee level 2 100 kva ( labour charges for handling & installation of distribution transformer ( dtr ) on dp, tightening with turn buckles on both sides, poles clamping and boting of base jumpering on ht side ] , stay clamp a type 65x8mm ms flat r.s. joist , 11 kv polymer lightening arrestor gapless type ( 1set=3no. ) with earthing , labour charges for fixing of 11 kv polymer lightening arrestor gapless type ( 1set=3no. ) with earthing , 11 kv. d.o. fuse unit ( 1set=3no. ) , labour charges for fixing of 11 kv. d.o. fuse unit ( 1set=3no. ) , aaac rabbit conductor 0.05 sq. inch. ( 55 sq.mm. al.eq. ) , danger boards enamelled 11 kv , labour charges for fixing of danger boards enamelled 11 kv , earthing set ( dtr earthing ) as per circular no 1516 dated 17.03.08 , earthing of new 33 / 11kv s / s as per schedule g 3 ( for black cotton soil ) ( as per drawing ) , 11 kv isolator complete with insulators 600 amp. w / o earth switch , fixing of 11 kv isolator complete with insulators 600 amp. w / o earth switch , 11 kv oil immersed 3 phase 4 wire ctpt units 300 150 / 5 amp ( me ) , installation of 11 kv oil immersed 3 phase 4 wire ctpt units 300 150 / 5 amp ( me ) , 33 kv cts. ( out door oil filled type ) 300 150 / 5 amps , handling & inst. of 33kv cts. 300 150 / 5amp ( handling & installation of ct with earthing arrengment ) , 33 kv top clamp 75x75x6mm angle type , labour charges for fixing of 33 kv top clamp 75x75x6mm angle type , dc channel 100x50x6 mm 4.8mtrs center to center , labour charges for fixing of dc channel 100x50x6 mm 4.8mtrs center to center ( dc cross arm along with plates of supporting clamps on both the poles ) , dc cross arms 5 center to center ( 100x50x6mm ) channel , fixing of dc cross arms 5 channel ( 100x50x6mm ) along with plates, 6 nos, h / ws, 6 nos. disc insulators and fixing of supporting clamps on both the poles , dc cross arms 8 channel ( 100x50x6mm ) , fixing of dc cross arms 8 channel ( 100x50x6mm ) along with plates, 6 nos, h / ws, 6 nos. disc insulators and fixing of supporting clamps on both the poles , transformer mounting channel ( 100x50x6mm ) , transformer clamping set 50x50x6mm angle 460mm , three phase static energy meters 20 80 amps with l.s. & tod facility with box , three phase static energy meters 20 80 amps with l.s. & tod facility with box [ labour only for installation of three phase meter on 12 x16 poly carbonate / wooden board ( excluding the cost of board ) , but including making holes in the board, fixing the board on the wall, screing the meter on the board, screwing incoming & outgoing terminals including earth terminals ] , horizonatal and cross bracing 5 centre with supporting clamps on both the poles , labour charges for fixing of horizonatal and cross bracing 5 centre with supporting clamps on both the poles , 11kv top clamp 75x40x6mm angle type ( s / s ) , labour charges for fixing of 11kv top clamp 75x40x6mm angle type ( s / s ) , h beam 152x152 mm, 37.1 kg / mtr. 13 mtr long , h beam 152x152 mm, 37.1 kg / mtr. 13 mtr long ( a ) . pit digging in soft rock for 13 mtr. h beam [ size ( 2x4x7 ) = 56 sq. feet ] ( b ) . h beam pole transportation 00km upto 01km ( c ) . h beam pole 13 mtr long erection , stay set without stay wire 20 mm ( painted ) , stay set without stay wire 20 mm ( painted ) a ) .stay pit digging ( 20 mm ) size ( 5x2.5x5 ) = 62.50 cu. feet b ) .stay set erection ( complete with binding of stay wire at eye bolt, stay insulator and anchor rod ) , stay gi wire 7 / 4.00 mm ( 7 / 8 swg ) , g.i. wires 5.0 mm ( 6 swg ) , g.i. wires 4.0 mm ( 8 swg ) , concreting of stay @ 0.3 cmt. per stay , labour charges for concreting of stay @ 0.3 cmt. per stay , 11 kv v cross arms 65x65x6mm with 11 kv top clamps , fixing of 11 kv v cross arms 65x65x6mm with 11 kv top clamps , anti climbing device ( barbed wire ) gs 2.24 mm dia ( 14 swg ) , labour charges for fixing of anti climbing device ( barbed wire ) gs 2.24 mm dia ( 14 swg ) , aluminium binding wire and tape , i. bolts 16 mm , jointing sleeves suitable for dog ( 100sq.mm.al. eq. ) aaac conductor , aaac / acsr raccoon conductor 0.075sq. inch ( 03no. condt. ) ( 11 kv ) , stringing of aaac / acsr raccoon conductor 0.075sq. inch ( 03no. condt. ) ( 11 kv ) , survey of 11 kv line during execution of work , pcc pole 9.1mtr., 280kg long , pcc pole 9.1mtr., 280kg long ( a ) pole pit digging in soft rock, 280 kg on pcc pole size ( 2x4x5 ) =40 feet ( b ) pole transportation 00km upto 01km ( c ) pcc pole errection with earthing , stay clamp 65x8 mm of ms flat for pcc pole 280kg , stay insulators 90x65mm , back filling of poles with boulders , back clamp for 280 kg pcc pole of ms flat 50x8 mm , aaac / acsr raccoon conductor 0.075sq. inch ( 03no. condt. ) ( 33 kv ) , stringing of aaac / acsr raccoon conductor 0.075sq. inch ( 03no. condt. ) ( 33 kv ) , survey of 33 kv line during execution of work , 33 kv v cross arm with 33 kv top clamp , labour charges for fixing of 33 kv v cross arm with 33 kv top clamp , ms strain plate 65x8 mm 250 mm long , 33 kv composite polymer disc insulators , 33 kv strain hardware ( t&c type ) fittings , dccross arms 5 along with plates, 6 no. h / ws, 6 nos. disc insulators and fixing of supporting clamps on both the poles ( 100x50x6mm ) channel , labour charges for fixing of dc cross arms 5 along with plates, 6 no. h / ws, 6 nos. disc insulators and fixing of supporting clamps on both the poles ( 100x50x6mm ) channel , 140 kg. 8.0 mtr. long pcc pole , 140 kg. 8.0 mtr. long pcc pole a ) . pole pit digging in soft rock for 140 kg pcc pole [ size ( 2x4x4.5 ) = 36 sq. feet ] b ) . pole transportation 00km upto 01km c ) . pcc pole 8 mtr long 140 kg erection with earthing , clamp for 140 kg pole pole ms flat 50x6 mm , concreting of stay @ 0.2 cmt / stay , labour charge for concreting of stay @ 0.2 cmt / stay , 11 kv v cross arms 75x40x6 mm with 11 kv top clamps , fixing of 11 kv v cross arms 75x40x6 mm with 11 kv top clamps , back clamp for 140 kg pcc pole ms flat 50x6 mm , concreting of stay @ 0.2 cmt. per stay , labour charges for concreting of stay @ 0.2 cmt. per stay , earthing for pcc pole 4.00 mm 8 swg g.i. wire 0.8 kg, per pole , horizonatal and cross bracing 8 centre with supporting clamps on both the poles , labour charges for fixing of horizonatal and cross bracing 8 centre with supporting clamps on both the poles , i. bolts 20 mm , 33 kv guarding of ms channel 75x40x6 mm ( carpet guarding ) , labour charges for fixing of 33 kv guarding of ms channel 75x40x6 mm ( carpet guarding ) , gst @ 18%...

Madhya Pradesh Madhya Kshetra Vidyut Vitaran Company Limited - Madhya Pradesh

32285350 additional ptr 3.15 mva at 33 / 11 kv rehti s / s at rehti under rehti d / c of ( oandm ) dn. budni 1 33 / 11 kv power transformer , oftc type , 3150 kva ( loss 3+15 kw ) ( rep bgp ) 2 33 kv vcb, outdoor porcelain cladtype with complete structure and accessories 3 11 kv vcb, outdoor porcelain cladtype with complete structure and accessories 4 h beams 152 x 152 mm., 37.1 kg. / meter 11 meter. long 5 h beams 152 x 152 mm., 37.1 kg. / meter9 meter. long 6 aaac dog conductor 0.10 sq. inch ( 100 sq.mm. al.eq. ) 7 11 kv.c.ts. ( outdoor dry type ) 300 150 / 5 5 amps 8 33 kv ct outdoor oil immersed type, 3 core, 200 100 / 5 5 1 amp, class 0.5 9 33 kv, isolator600 amp. ( turn and twist type ) 10 11 kv, isolator800 amp. ( turn and twist type ) 11 11 kv strain hardware ( t&c type ) fittings 12 11 kv polymer pin insulator 13 9 kv gapless type ( 5 ka ) polymer lightening arrestor 14 33 kv pt outdoor type single phase, 33 / ?3 kv / 110 / ?3 v 15 33 kv polymer lightening arrestor gapless type 16 11 kv.c.ts. ( outdoor dry type ) 200 100 / 5 amps 17 11 kv pt single phase 18 ms strain plate 65x8mm 250mm long 19 danger boards enamelled 11 kv 20 11 kv control & relay panel withstatic relay fortransformer protection 21 33 kv control & relay panel withstatic relay fortransformer protection 22 3ph 4w 3x63.5v lb=5a imax=10a, ht trivector meter, 0.5s, dlms cat a, gsm ( s / s meter ) 23 copper control cable 12 core. 2.5 sq.mm. ( unarmoured ) 24 copper control cable 8 core. 2.5 sq.mm. ( unarmoured ) 25 copper control cable 4 core. 2.5 sq.mm. ( unarmoured ) 26 copper control cable 2 core. 2.5 sq.mm. ( unarmoured ) 27 marshelling box with 10 no. connectors 28 t clamp for 33kv & 11kv bus, substation 29 bi metallic clamp for power transformer of brass flat 50x50x10mm 30 sheet metal meter box suitable for h.t. static travector meters with ttb 31 d.c. channel ( 3.8 mtrs ) 100x50x6mm ( set ) 32 d.c. cross arms 5 centre to center ( 100x50x6 mm ) channel 33 33 kv, 10 kn pincomposite polymer insulator 34 33 kv composite polymer disc insulators 35 d.c. cross arms 8 channel ( 100x50x6mm ) 36 11 kv composite polymer disc insulators 37 bracing / support angle of 65x65x6 mm for 8 feet ( 2.45 mtr ) centre dp 38 h.beam back clamps65x8mm flat ( in numbers ) 39 h.beamclamps65x8mm flat 40 concreting of rail / hbeam supports @0.56 cmt.per pole including muffing of pole 41 concreting of rail / hbeam supports @0.36 cmt.per pole including muffing of pole 42 concreting of foundation of vcb ( 1:3:6 ) @ 3.5 cmt per vcb plinth 43 concreting of stay ( 20 mm / 25 mm ) @ 0.3 cmt. per stay 44 ptr fndn.cncrt.:1:1.5:3 rio 5.634, 1:5:8 rio 7.545 cmt&m.s.flat / rod 324.87 kg 45 earthing coil of 115 turns of 50 mm.dia and 2.5 mtr lead of 4.0 mm g.i wire 46 m.s.nuts and bolts 47 red oxide paint 48 aluminium paint 49 anti climbing device ( barbed wire ) gs 2.24 mm dia ( 14 swg ) 50 danger boards enamelled 33 kv 51 33 kv strain hardware ( t&c type ) fittings 52 d.c. channel 100x50x6mm 4.8 mtrs center to center 53 stay gi wire 7 / 4.00 mm. ( 7 / 8 swg ) 54 stay set without stay wire 20 mm. ( painted ) 55 galvanized iron ( gi ) flat 50x6 mm 56 g.i.pipe 40 mm dia c grade type 57 gi pipe 150 mm b grade 58 earthing rod 3 mtrs. ( gelvanised ) 25 mm rod 59 bentonite compound powder 60 labour charges 61 transportation charges with ptr & pole from area store to site 62 gst on transportation@5% 63 gst on contractor side material & labour charges @18%...

Madhya Pradesh Madhya Kshetra Vidyut Vitaran Company Limited - Madhya Pradesh

32267418 2 km 11kv agr feeder bifurfaction for sukarwas, magariya and manjakhedi from 33 / 11 kv vasudev s / s with 1 no. 11 kv additional bay under gopalpur d / c of ( oandm ) dn. nasrullaganj 1 aaacraccoon conductor0.075 sq. inch ( 80 sq.mm. al.eq. ) 2 acsrdog conductor 0.10 sq. inch ( 100 sq.mm. al.eq. ) 3 h beams 152 x 152 mm., 37.1 kg. / meter11 meter. long 4 h beams 152 x 152 mm., 37.1 kg. / meter9 meter. long 5 pcc pole 9 m , 200kg 6 11 kv vcb, outdoor porcelain cladtype with complete structure and accessories 7 3ph 4w 3x63.5v lb=5a imax=10a, ht trivector meter, 0.5s, dlms cat a, gsm ( s / s meter ) 8 11 kv ab switch polymer type 400 amp with complete fitting 9 11 kv control & relay panel with static relay forfeeder protection 10 11 kv, isolator800 amp. ( turn and twist type ) 11 11 kv.c.ts. ( outdoor dry type ) 300 150 / 5 5 amps 12 11 kv single phase pts. ( resin molded ) 13 11 kv strain hardware ( t&c type ) fittings 14 11 kv polymer pin insulator 15 9 kv gapless type ( 5 ka ) polymer lightening arrestor 16 danger boards enamelled 11 kv 17 m.s.flat 50x6mm 18 copper control cable 12 core. 2.5 sq.mm. ( unarmoured ) 19 d.c. cross arms 8 channel ( 100x50x6mm ) 20 ms strain plate 65x8mm 250mm long 21 d.c. channel 100x50x6mm 4.8 mtrs center to center 22 bracing / support angle of 65x65x6 mm for 8 feet ( 2.45 mtr ) centre dp 23 33 kv composite polymer disc insulators 24 11 kv composite polymer disc insulators 25 danger boards enamelled 33 kv 26 copper control cable 8 core. 2.5 sq.mm. ( unarmoured ) 27 copper control cable 4 core. 2.5 sq.mm. ( unarmoured ) 28 red oxide paint 29 aluminium paint 30 anti climbing device ( barbed wire ) gs 2.24 mm dia ( 14 swg ) 31 aluminium binding wire and tape 32 m.s.nuts and bolts 33 11 kv top clamp 65x65x6 mm. angle type 34 11 kv v cross arm 65x65x6 mm. angle type 35 clamp for 140 kg pcc pole ms flat 50x6 mm 36 back clamp for 140 kg pcc pole ms flat 50x6 mm 37 earthing coil of 115 turns of 50 mm.dia and 2.5 mtr lead of 4.0 mm g.i wire 38 stay gi wire 7 / 4.00 mm. ( 7 / 8 swg ) 39 stay set without stay wire 20 mm. ( painted ) 40 concreting of h beam pole@ 0.56 cmt per pole including muffing of pole 41 concreting of pcc pole@ 0.36 cmt per pole for base padding for dp / tp 42 concreting of foundation of vcb ( 1:3:6 ) @ 3.5 cmt per vcb plinth 43 concreting of structures & foundation ( 1:3:6 ) 44 concreting of stay ( 20 mm / 25 mm ) @ 0.3 cmt. per stay 45 stay clamp65x8 mm of ms flat for pcc pole 280kg. 46 earthing for pcc pole4.00 mm 8 swg g.i wire 0.8 kg, per pole 47 sheet metal meter box suitable for h.t. static travector meters with ttb 48 marshelling box with 10 no. connectors 49 t clamp for 33kv & 11kv bus, substation 50 h.beamclamps65x8mm flat 51 h.beamclamps65x8mm flat ( in numbers ) 52 p&f perfo cable tray 300 wide, 2 thick fix45x45x5 ms angle grouted cc 1:24 53 labour charges 54 transportation charges for all equipments & materials from store to site 55 gst on transportation@5% 56 gst on contractor side material & labour charges @18%...

Madhya Pradesh Madhya Kshetra Vidyut Vitaran Company Limited - Madhya Pradesh

32267383 4 km 11kv dlf feeder bifurfaction for sukarwas, magariya and manjakhedi from 33 / 11 kv vasudev s / s with 1 no. 11 kv additional bay under gopalpur d / c of ( oandm ) dn. nasrullaganj 1 aaacraccoon conductor0.075 sq. inch ( 80 sq.mm. al.eq. ) 2 acsrdog conductor 0.10 sq. inch ( 100 sq.mm. al.eq. ) 3 h beams 152 x 152 mm., 37.1 kg. / meter9 meter. long 4 pcc pole 9 m , 200kg 5 11 kv vcb, outdoor porcelain cladtype with complete structure and accessories 6 3ph 4w 3x63.5v lb=5a imax=10a, ht trivector meter, 0.5s, dlms cat a, gsm ( s / s meter ) 7 11 kv ab switch polymer type 400 amp with complete fitting 8 11 kv control & relay panel with static relay forfeeder protection 9 11 kv, isolator800 amp. ( turn and twist type ) 10 11 kv.c.ts. ( outdoor dry type ) 300 150 / 5 5 amps 11 11 kv single phase pts. ( resin molded ) 12 11 kv strain hardware ( t&c type ) fittings 13 11 kv polymer pin insulator 14 9 kv gapless type ( 5 ka ) polymer lightening arrestor 15 danger boards enamelled 11 kv 16 m.s.flat 50x6mm 17 copper control cable 12 core. 2.5 sq.mm. ( unarmoured ) 18 d.c. cross arms 8 channel ( 100x50x6mm ) 19 ms strain plate 65x8mm 250mm long 20 d.c. channel 100x50x6mm 4.8 mtrs center to center 21 bracing / support angle of 65x65x6 mm for 8 feet ( 2.45 mtr ) centre dp 22 33 kv composite polymer disc insulators 23 11 kv composite polymer disc insulators 24 danger boards enamelled 33 kv 25 copper control cable 8 core. 2.5 sq.mm. ( unarmoured ) 26 copper control cable 4 core. 2.5 sq.mm. ( unarmoured ) 27 red oxide paint 28 aluminium paint 29 anti climbing device ( barbed wire ) gs 2.24 mm dia ( 14 swg ) 30 aluminium binding wire and tape 31 m.s.nuts and bolts 32 11 kv top clamp 65x65x6 mm. angle type 33 11 kv v cross arm 65x65x6 mm. angle type 34 clamp for 140 kg pcc pole ms flat 50x6 mm 35 back clamp for 140 kg pcc pole ms flat 50x6 mm 36 earthing coil of 115 turns of 50 mm.dia and 2.5 mtr lead of 4.0 mm g.i wire 37 stay gi wire 7 / 4.00 mm. ( 7 / 8 swg ) 38 stay set without stay wire 20 mm. ( painted ) 39 concreting of pcc pole / hbeam supports @ 0.36 cmt per pole for base padding for dp / tp including muffing of pole etc 40 concreting of foundation of vcb ( 1:3:6 ) @ 3.5 cmt per vcb plinth 41 concreting of structures & foundation ( 1:3:6 ) 42 concreting of stay ( 20 mm / 25 mm ) @ 0.3 cmt. per stay 43 stay clamp65x8 mm of ms flat for pcc pole 280kg. 44 earthing for pcc pole4.00 mm 8 swg g.i wire 0.8 kg, per pole 45 sheet metal meter box suitable for h.t. static travector meters with ttb 46 marshelling box with 10 no. connectors 47 t clamp for 33kv & 11kv bus, substation 48 h.beamclamps65x8mm flat 49 p&f perfo cable tray 300 wide, 2 thick fix45x45x5 ms angle grouted cc 1:24 50 labour charges 51 transportation charges for all equipments & materials from store to site 52 gst on transportation@5% 53 gst on contractor side material & labour charges @18%...

Madhya Pradesh Power Generating Company Limited - Madhya Pradesh

32255378 procurement of various control relay for ht lt switchgear for emd iv, stps, mppgcl, sarni. procurement of various control relay for ht lt switchgear for emd iv, stps, mppgcl, sarni. , various control relay for ht/lt switchgear , control relay, 10a, coil voltage 220v dc , contact configuration 4 no ref tca3 dn40 , control relay, 10a, coil voltage 220v dc , contact configuration 2 no + 2nc ref tca3 dn22 , add on block front mounted 4 no ref tca1 dn40 , add on block front mounted 2 no + 2 nc ref tca1 dn22 , voltage operated auxiliary relay re 300, 5 amp at 220v dc, 4 c/o contacts, with plug in base suitable for front connection, electromechanical flag or led indicator, coil voltage dc: 220v dc,coil operating voltage : 80% to 110% of rated voltage , coil burden 4 watts ref re 300 ( 220v dc ) , voltage operated auxiliary relay re 300, 5 amp at 24v dc , 4 c/o contacts, with plug in base suitable for front connection, electromechanical flag or led indicator, coil voltage dc: 24v dc, coil operating voltage : 80% to 110% of rated voltage , coil burden 4 watts ref re 300 (24v dc)...

Madhya Pradesh Madhya Kshetra Vidyut Vitaran Company Limited - Madhya Pradesh

32170411 1 nos. 33 kv power evacaution works newly constructed ehv 220 / 132 / 33 kv s / s mahukalan ( budni ) at place pilikara to mana s / s of ( oandm ) dn. budni 1 33 kv vcb, outdoor porcelain cladtype with complete structure and accessories 2 h beams 152 x 152 mm., 37.1 kg. / meter 13 meter. long 3 h beams 152 x 152 mm., 37.1 kg. / meter9 meter. long 4 acsrdog conductor 0.10 sq. inch ( 100 sq.mm. al.eq. ) 5 aaac dog conductor 0.10 sq. inch ( 100 sq.mm. al.eq. ) 6 33 kv control & relay panel with numerical static relay forfeeder protection 7 33 kv ct outdoor oil immeresed type 3 core, 200 100 / 5 5 1 amp, class 0.5 8 33 kv pt outdoor type single phase, 33 / ?3 kv / 110 / ?3 v 9 33 kv, isolator600 amp. ( turn and twist type ) 10 m.s. flat 50x6 mm 11 ms strain plate 65x8mm 250mm long 12 copper control cable 12 core. 2.5 sq.mm. ( unarmoured ) 13 single pole cut point channal ( 100x50x6mm ms channel ) 1.65 mtr long 14 33 kv strain hardware ( t&c type ) fittings 15 red oxide paint 16 aluminium paint 17 anti climbing device ( barbed wire ) gs 2.24 mm dia ( 14 swg ) 18 m.s.nuts and bolts 19 danger boards enamelled 33 kv 20 earthing coil of 115 turns of 50 mm.dia and 2.5 mtr lead of 4.0 mm g.i wire 21 33 kv composite polymer ab switch 22 33 kv polymer lightening arrestor gapless type 23 33 kv v cross arm 1.5 mtr ( 5ft ) centre made from 75x75x6mm angle 24 33 kv top clamps 75x75x6 mm angle 25 33 kv, 10 kn pincomposite polymer insulator 26 33 kv composite polymer disc insulators 27 d.c. cross arms 5 centre to center ( 100x50x6 mm ) channel 28 d.c. channel 100x50x6mm 4.8 mtrs center to center 29 stay set without stay wire 20 mm. ( painted ) 30 stay gi wire 7 / 4.00 mm. ( 7 / 8 swg ) 31 concreting of foundation of vcb ( 1:3:6 ) @ 3.5 cmt per vcb plinth 32 concreting of stay ( 20 mm / 25 mm ) @ 0.3 cmt. per stay 33 concreting of structures & foundation ( 1:3:6 ) 34 copper control cable 8 core. 2.5 sq.mm. ( unarmoured ) 35 copper control cable 4 core. 2.5 sq.mm. ( unarmoured ) 36 h.beamclamps65x8mm flat 37 h.beam back clamps65x8mm flat ( in numbers ) 38 sheet metal meter box suitable for h.t. static travector meters with ttb 39 marshelling box with 10 no. connectors 40 t clamp for 33kv & 11kv bus, substation 41 jointing sleeves suitable for dog ( 100 sq.mm.al.eq. ) aaac conductor 42 bracing / support angle of 65x65x6 mm for 5 ( 1.5 mtr ) centre dp 43 labour charges 44 transportation charges for all equipments & materials from store to site 45 gst on transportation@5% 46 gst on contractor side material & labour charges @18%...

Madhya Pradesh Power Generating Company Limited - Madhya Pradesh

32073268 procurement of alstom make electro mechanical relay for t n c division of 210 mw atps mppgcl chachai procurement of alstom make electro mechanical relay for t n c division of 210 mw atps mppgcl chachai , idmt over current & earth fault relay – 51 / 51 n , senstive earth fault relay ( 50n2 ) , senstive earth fault relay ( 50n2 ) , tripping relay ( 86 ) , tripping relay ( 86 ) ( grp panel ) , instantaneous earth fault relay ( ref. protection relay ) – ( 64r ) , under voltage relay type vagm ( universal instantaneous ) ( 27m1, 27m2, 27m3 ) , under voltage relay ( under voltage 50% ) , instantaneous over current relay, type cdg61 ( inverse ) & earth fault relay ( set of 3 ) , 3 phase over current relay set, type cdg31 , trip circuit supervision relay 95 , trip circuit supervision relay – 95, type vax mkii , idmt o / c & inst o / c relay ( 51 / 50 ) , auxiliary relay type vaa11 , auxiliary relay type vaa31 , auxiliary relay type vaa21 , breaker multiplication relay type vajc , anti pumping relay type vaa , fuse failure relay 98 , fuse failure relay , hs tripping relay – 86m1 , check synchronizm relay, type ske , rotor earth fault relay vaem 21 , battery earth fault type caem mc 11 , instantaneous over voltage relay type vag , instantaneous differential relay type cag , definite time reverse power relay ccum & definite time relay type vtt , neutral displacement relay type vdg , definite time o / c relay type ctu ( phase o / c ) , test terminal plug ( type mpb ) , ten pairs of silver plated finger contacts , test terminal block ( type mpg ) , control relay type vajc...

Madhya Pradesh Power Generating Company Limited - Madhya Pradesh

31929664 procurement of alstom make electro mechanical relay for t and c division of 210 mw atps mppgcl chachai procurement of alstom make electro mechanical relay for t and c division of 210 mw atps mppgcl chachai , idmt over current & earth fault relay – 51/51 n , senstive earth fault relay (50n2) , senstive earth fault relay (50n2) , tripping relay (86) , tripping relay (86) (grp panel) , instantaneous earth fault relay (ref. protection relay) – ( 64r) , under voltage relay type vagm ( universal instantaneous) (27m1, 27m2, 27m3) , under voltage relay (under voltage 50%) , instantaneous over current relay, type cdg61 (inverse) & earth fault relay ( set of 3) , 3 phase over current relay set, type cdg31 , trip circuit supervision relay 95 , trip circuit supervision relay – 95, type vax mkii , idmt o/c & inst o/c relay (51/50) , auxiliary relay type vaa11 , auxiliary relay type vaa31 , auxiliary relay type vaa21 , breaker multiplication relay type vajc , anti pumping relay type vaa , fuse failure relay 98 , fuse failure relay , hs tripping relay – 86m1 , check synchronizm relay, type ske , rotor earth fault relay vaem 21 , battery earth fault type caem mc 11 , instantaneous over voltage relay type vag , instantaneous differential relay type cag , definite time reverse power relay ccum & definite time relay type vtt , neutral displacement relay type vdg , definite time o/c relay type ctu ( phase o/c) , test terminal plug (type mpb),ten pairs of silver plated finger contacts , test terminal block ( type mpg) , control relay type vajc...

Madhya Pradesh Power Generating Company Limited - Madhya Pradesh

31893909 procurement of c and s make auxiliary contactor, power contactors, circuit breaker and its spares installed at esp at 2x660mw, sstpp, mppgcl, khandwa , 32a contactor, 240vac, tc1d3210u5cat no. tc1d3210u5 , add on block ta1 dn11cat no. ta1 dn11 , 200a contactor, 110v accat no. lc1fdp200au5 , sfu315a tpn din typecat no. cssdf315d3n , sfu63a tpn din typecat no. cssdf63d3n , sfu 32a tpncat no. cssdf32d3n , 1000a, acb50ka edo with mp3.1 release, position indication switchcat no. aha10n3pedmp3.1 ( s ) , independent mounting contactor, ta7 d0964cat no. ta7 d0964 , thermal olr, tr2 d09305cat no. tr2 d09305 , 250a mccb tp mpcat no. cse2s250etm3p 250a , 250a mccb tp tmcat no. cse2m250atm3p 250 , 100a mccb tp tmcat no. cse1m125atm3p 100 , 400a mccb mpcat no. cse400net33400a3pe , 160a contactor 220vac coilcat no. tc1d16011m5 , control relay 240vac, tca2dn22cat no. tca2dn22 , add on block for ta1 dn22cat no. ta1 dn22 , spare contact kit for 200a contactorcat no. la5 fg431 ( f200 ) , spare contact coil for 200a contactor 110vaccat no. lx1fg 110v , main isolating contact ( jaw contact ) cat no. cs mic 08d ( 50k ) , arcing contactcat no. cs arccont 08d , main fixed contact ( upper terminal ) cat no. fixcont 08n , lower terminal with fitting platecat no. lwr trnl 8d , cradle terminal for draw outcat no. cs ckttml 08n , arc chutecat no. cs arccht o6d 16d , charging motor 220vdccat no. cs amh 1 , control relay for charging motorcat no. cs amh 1 2s , micro switch for motor cut offcat no. microsw , frp laminated safety shutter 3 polecat no. ash 1 , aux isolating contact assemblycat no. cs aih 3 116 , aux switch 7no+7nccat no. cs axh 7a7b 116 , shunt trip coil 220v dccat no. cs avh s 116 md , closing coil 220v dccat no. cs avh c 116 md , position indicating switch rightcat no. alb 4p 1 , key lock ( 1lock+1 key ) cat no. aki 116d , lower mechanism ( 6d 16d ) cat no. lwrmech6~16d , draw out gear assemblycat no. dograsy 116 3p , charging hookcat no. chook 16b , charging hook pincat no. clchookpin 16b , charging hook springcat no. chkspg 16b , charging latch pincat no. clatchpin 16b , charging latch cat no. clatch 16b , charging latch springcat no. clatchspg 16b , front covercat no. fcover 6d 16d , dowell pincat no. csspgdlpn013 , closing coil limit switchcat no. cclimsw , single pole completecat no. cs condunit 8n...

Madhya Pradesh Madhya Kshetra Vidyut Vitaran Company Limited - Madhya Pradesh

31684583 procurement of 11kv and 33 kv control and relay panel procurement of 11kv and 33 kv control and relay panel , 11kv feeder control panel ( for one feeder ) , 11kv feeder control panel ( for two feeder ) , 11kv control & relay panel for capacitor bank , 33kv transformer control panel , 33kv transformer control panel with differential relay for 8 mva transformer...

Madhya Pradesh Power Generating Company Limited - Madhya Pradesh

31625320 procurement of c andi spares for carrier fire and security ( edwards est 3 fire fighting system ) make fire fighting system of 2x600 mw of sstpp, dongalia, khandwa procurement of c andi spares for carrier fire and security ( edwards est 3 fire fighting system ) make fire fighting system of 2x600 mw of sstpp, dongalia, khandwa , est3 power supply ( 3 pps / m 230 ) , power supply for edward make panel, hsn / sac code: 85311090 , est3 960 character lcd display ( 3 lcdxl1 ) , display board for edward make panel, hsn / sac code: 85311090 , est3 rs232 card ( 3 rs232 ) , rs 232 card for edward make panel, hsn / sac code: 85311090 , est3 dual loop card ( 3 sddc1 ) , dual loop card for edward make panel, hsn / sac code: 85311090 , est3 fiber optic interface module 3 fibmb2, fiber optic network card for edward make panel, hsn / sac code: 8531 , est3 fiber ( smxlo2 ) , communication module for edward make panel one panel need two nos incase both end is in fiber connectivity, hsn / sac code: 8531 , est optica multi detector siga ohsd, hsn / sac code: 8531. , est optica smoke detector siga osd, hsn / sac code: 8531. , est isolator base ( siga ib ) , hsn / sac code: 85311090. , est heat detector ( siga hrd ) , siga hrs is absolute and new model is back to back compatible with old panel hsn / sac code: 85311090 , est monitor module ( siga ct1 ) , hsn / sac code: 85311090. , est control module ( siga cr ) , hsn / sac code: 85311090. , est3 control relay module ( siga cc1 ) , hsn / sac code: 85311090 , est manual call point ( siga 278 ) , sigi271 is not ul & fm listed product so we have quoted dual stage which is higher specks and resettable through key, hsn / sac code: 85311090. , est hooter cum strobe ( g1avrf ) , quoted edward make ul / fm listed product led strobe, hsn / sac code: 85311090. , edward probe type detector 302 epm 135 ( ul / fm listed ) hsn / sac code: 8531 , flameproof junction box for probe type heat detector and module installation, hsn / sac code: 8535 , flameproof gland double compressor gland, hsn / sac code: 7318. , est weather proof manual call point ( mpsr2 s45w ) ( ul / fm listed ) , hsn / sac code: 85311090 , est standard base ( siga sb ) hsn / sac code: 85311090 , response indicator, hsn / sac code: 8535....

Madhya Pradesh Power Transmission Company Limited - Madhya Pradesh

31360614 procurement of ehv grade i transformer oil (tr 04/2022) procurement of ehv grade i transformer oil (tr 04/2022) , electrical items : , ehv grade i transformer oil for power transformers conforming to all technical particulars as detailed out in annexure i (volume ii) attached. the oil should be supplied in road tankers with nitrogen cushioning under positive pressure , (b) structure for item 3 (a) above , (a) 36 kv gapless lightning arrester with terminal connector meeting the technical requirement as per section – iii, annexure iii , (b) structure for item 4 (a) above , (a)33 kv isolator with earth switch complete with insulators & all accessories meeting the technical requirement as per section – iii, annexure iv , (b) structure for item 5 (a) above , 33 kv vacuum circuit breaker with structure meeting the technical requirement as per section – iii, annexure v , 33 kv control & relay panel meeting the technical requirement as per section – iii, annexure vi , 33 kv bolted type post insulator structure complete with 33 kv post insulators meeting the technical requirement as per section – iii, annexure vii...

South Eastern Coalfields Limited - Madhya Pradesh

31332436 bids are invited for 3.3kv offload type on off isolator 200amps ht 100 old p no ht001 , fixed contact for isolator set of 3 ht 100 by 1 old p no ht002 , moving contact for isolator set of 3 ht 100 by 2 old p no ht003 , 3.3kv 400amps vacuum contactor complete ht 200 old p no ht004 , bridge rectifier unit complete ht 201 old p no ht005 , vacuum interrupter 400amps for contactor ht 202 old p no ht006 , 110v dc closing coil for v c ht 203 old p no ht007 , 110v dc holding coil for v c ht 204 old p no ht008 , limit switch 2 no 2 nc for vacuum contactor with braket ht 205 old p no ht009 , control transformer 40va pri 0 110v sec 0 8 12v ht 206 old p no ht010 , control relay 110v ac no 1 nc ht 208 old p no ht011 , 1ph 750va 3.3kv 110 volts moulded type potential transformer ht 300 old p no ht012 , p.t. fuse 3.3kv 2a ht 400 old p no ht013 , core balance current transformer for elr moulded type ht 500 old p no ht014 , current transformer for overload relay moulded ring type ht 600 old p no ht015 , current transformer forammeter moulded ring type ht 650 old p no ht016 ,moulded insulator for power fuse ht 700 old p no ht017 ,earth leakage relay complete range 0.75 to 2a withouttransformer ht 800 old p no ht019 , oil dashpot typeelectromagnetic overload relay ht 900 old p no ht020 ,ammeter 3 inch sqare suitably scaled ht 1000 old p noht021 , voltmeter 3 inch sqaure range 0 to 5kv ptr 3.3kv110 volts ht 1100 old p no ht022 , 20a fuse base andcarrier ht 1200 old p no ht023 , 4a fuse link ht 1201 oldp no ht024 , push button with element no or nc ht 1300old p no ht025 , indicating lamp holder with lamp for flpstarter ht 1400 old p no ht026 , 3.3kv hrc power fusesuitably rated ht 1500 old p no ht027 , double conicalbrass cable gland complete size ht ht 1600 old p noht028 , m. s. cable box complete without gland ht 1600 aold p no ht029 , isolator operating handle complete on offht 1501 old p no ht031 total quantity : 174...

Madhya Pradesh Power Generating Company Limited - Madhya Pradesh

31315136 procurement of spares for m / s kone make elevator installed at t.g. building for 210mw atps, mppgcl, chachai. procurement of spares for m / s kone make elevator installed at t.g. building for 210mw atps, mppgcl, chachai. , guide shoe assy, sliding 10mm 150x139x110 , pcb, unit amd drive 2 , push button assy , guide shoe liner, 10mm 120x41x27.5 hdpe , guide shoe liner, 16mm 120x41x27.5 hdpe , contactor, 230vac 80a ac 3 3no , control relay, ca2kn40m7 220 / 230v , coupler, lock railing 2 centre opening , pcb, i / o card , pcb, bam card , pcb, cpu card , toothed belt, l2250mm h3.8mm , support, toothed pulley d43mm , ac 4 relay, 230v 1c.o / new / c / 4x24v dc , dc relay card, 4r 1c imported relay , dc relay card, 8r 1c imported relay , door glide shoe amd, nylon 6 , tl jones curtain of light , pf & rr card, f cntlr assy 216 416 mesb , roller, lock d31.5 w=23mm r2 , rope, closing wt assy d1.6 l=2900mm , board, mother tms 216 pth ocb 2.4 mm fr4 , break magnet, mr26 , osc switch assy , pcb assy, decoder / driver card 2 digit , transformer, drive2 115v / 225v / 385v , transformer, 200va , capacitor, 4mfd 400 / 440vac , electrol capacitor, al , bridge rectifier, srm 10p mrb metal , call connection card , i / o connection card , braking unit, 460v 45kw ( cdbr 4045d ) , tivela oil s220 , axial flow fan, 300mm sweep ebm papst , vane, al sheet s=1 80x150mm , vane, al 1x80x300mm , osg assy, 1m / s lh / rh d206 w test groove , brake shoe w liner, mr26 , shorting piece , track roller assy, d36x60x70 , pit switch assy, 1 nc 230vac , transformer, 400va , transformer, 100va , timer card, on & off delay , blower assy, mr26 winding unit , antilift roller, d10 , traction sheave, d600 8xd13 mr26 , rope diverting pulley, rh w bracket , pulley, rope diverting, lh w bracket , limit switch, k 40 , tension weight assy, upto 60m , pcb, power supply sreg board 400v , pcb assy, decoder / driver card 2 digit , switch selector, 1no+2nc , selector actuator, black...

Smart City Development Limited - Madhya Pradesh

31208486 design, engineering, procurement, construction of abd 1 substation and all associated infrastructure & interior works including operation and maintenance of entire facility for three years and trail run in satna, madhya pradesh. 1 33kv bay extension in the source substation with feeder protection 2 33 kv vcb, outdoor porcelain cladtype with complete structure and accessories 3 33 kv cts ( out door oil filled type ) 300 150 / 5 amps 4 33 kv control & relay panel with scada compatiblefor feeder protection ( for 1 feeder ) 5 33 kv isolator 600 a. ( turn & twist type ) 6 33 kv / 110 v 3p4w ct / pt ratio 400 200 / 5 amp. outdoor oil immersed type 7 copper control cable 12 core, 2.5 sqmm pvc unarmored 8 copper control cable 4 core, 2.5 sqmm pvc unarmoured 9 shield cable from control pannel to rtu panel ( 17 core*1.5sqmm ) 10 structures and bus bar arrangements 11 h beam 9 meter 152 x 152 mm 37.1 kg / meter = 333.9 kg.for 33kv gantry structure 12 clamp suitablefor 152 x 152 mm., 37.1 kg. / mtr 13 mtr. long h beam ( each weight 3.2 kg ) 13 strain plat ( is ms flat 65x8x250mm ) 0.65 kg each 14 acsrpanther conductor 0.20 sq. inch ( 200 sq.mm al.eq. ) 15 33 kv, 10 kn pincomposite polymer insulator, frp dia 33.5mm 16 33 kv top clamps 75x75x6 mm angle ( each weight 3.58 kg ) 17 33 kv , 45 kn 16mm frp with 25mm per kv creepage disc polymer long rod type t&c insulator ( for 33kv side ) 18 33 kv composite polymer strain set with hard ware suitable for panther conductor ( for 33kv side ) 19 33 kv , 45 kn 16mm frp with 25mm per kv creepage disc polymer long rod type t&c insulator ( for 11kv side ) 20 stone block / pre cast block for base pedding 450x450x75mm 21 concreting ( 1:3:6 ) of h beam @ 0.65cmt.per pole including muffing 22 other miscellaneous items 23 concreting ( 1:3:6 ) of vcb structures 3.5 cmt per vcb & pole @0.45 cmt. per structure 24 concreting ( 1:3:6 ) of isolator support structure @ 0.1 cmt. per structure 25 r.s.joist 175x85mm 9 mtr. long for yard lightening 26 pvc cable 2 corearmoured 2.5 sqmm aluminium conductor 27 pvc cable 4 corearmoured 16 sqmm aluminium conductor 28 m s bolt with nut16x250 mm 29 m s bolt with nut 16x200 mm 30 m s bolt with nut 16x165 mm 31 m s bolt with nut16x140 mm 32 m s bolt with nut16x90 mm 33 m s bolt with nut16x40 mm 34 red oxide paint 35 aluminum paint 36 danger board enameled 33 kv 37 for 33kv underground cable from abd 1 substation to each project area ( aac & lake nectar ) 38 33 kv3x300 sq mm xlpe cable with inner side shall be waterproofing with insulation of individual core and outer side of cable shall be stretch resistance. 39 termination kit for 33 kv grade xlpe cable for 3 core 300 sq mm ( 3 x 240 400 sq. mm. ) 40 heat shrinkable cable ( straight through ) jointing kit with lugs for 33 kv grade xlpe cable for 3 core 300 sq mm 41 supplying and installing double wall corrugated pipes ( dwc ) of hdpe ( is 14930 part ii marked ) for cable laid underground with necessary material and at required depth upto 90cm. below road / ground surface, including excavation, back filling with excavated material, ramming and making the surface good.210.00mm outside dia. 42 supply of approved type cable cover flag stone 200mm width & 32mm to 50mm thick of required length inclusive of transport as required. 43 laying of one number 3 core h.t armoured / unarmoured power cable 33kv grade of size not exceeding 300 sq. mm in the existing rcc / hume / stoneware / g.i. pipe / surface in existing trench as required. 44 33 / 11 kv transformers 45 33 / 11 kv power transformer , oftc type5000 kva loss ( 4 kw + 23 kw ) , with off load tap changer, 3 ph, 50 hz, onan, cu wound, outdoor conventional type power transformer along with transformer oil, buchholtz relay, breather, oti & wti, marshalling box, conservator tank, oil level indicator, valves, 2 sets of 50x8 mm gs neutral earthing strips { ( with braided conductor on bushing end ) , isolating link, isolation with insulators } , vent explosion plug, control wiring between sensing equipment and marshalling box, cable supporting tray on the body of transformer, transformer wheels, cable junction box lv / hv bushing etc as required as per technical specifications, approved drawings and scope of the work. 46 ptr foundation 47 scada compatible winding temp. indicator 48 scada compatible oil temp. indicator 49 33 kvla polymer type gapless / metal oxide substation type 50 11 kvla polymer type gapless / metal oxide 9 kv , 10 kasubstation type 51 remote terminal unit ( rtu ) including software for 2 no. power transformer 52 11 kv1500 kvar auto switch indoor capacitor bank including associated equipments such as 11 kv vacuum circuit breaker, control panel, 11 kv outdoor current transformer with adequate metering & protection class of service, bus & equipment isolators with earth switch, matching rvt, suitable gapless lightening arrestors, necessary cables for successful commissioning complete 53 for 33kv underground cable from abd 1 substation to each project area ( aac & lake nectar ) 54 33 kv3x300 sq mm xlpe cable with inner side shall be waterproofing with insulation of individual core and outer side of cable shall be stretch resistance. 55 termination kit for 33 kv grade xlpe cable for 3 core 300 sq mm ( 3 x 240 400 sq. mm. ) 56 heat shrinkable cable ( straight through ) jointing kit with lugs for 33 kv grade xlpe cable for 3 core 300 sq mm 57 supplying and installing double wall corrugated pipes ( dwc ) of hdpe ( is 14930 part ii marked ) for cable laid underground with necessary material and at required depth upto 90cm. below road / ground surface, including excavation, back filling with excavated material, ramming and making the surface good.210.00mm outside dia. 58 supply of approved type cable cover flag stone 200mm width & 32mm to 50mm thick of required length inclusive of transport as required. 59 laying of one number 3 core h.t armoured / unarmoured power cable 33kv grade of size not exceeding 300 sq. mm in the existing rcc / hume / stoneware / g.i. pipe / surface in existing trench as required. 60 for 11kv underground cable from abd 1 substation to each project area ( indoor sports complex ) 61 3 core xlpe cable 11 kv grade, high tension xlpe cable, 3 core 300 sq.mm armoured al. conductorsupply of approved high tension xlpe cable ( conforming is 7098 / ii / 85 ) as per isi standard 3 core armoured with alu. solid / stranded conductor isi marked as required 62 termination kit 11 kv xlpe cable o.d. termination, 3 x 240 400 sq. mm 63 heat shrinkable jointing kit 11 kv xlpe cable straight joint, 3 x 240 300 sq. mm. 64 supply of approved type cable cover flag stone 200mm width & 32mm to 50mm thick of required length inclusive of transport as required. 65 laying of one number 3 core h.t armoured / unarmoured power cable of grade exceeding 1.1kv but not exceeding 11kv of size not exceeding 300 sq. mm in the existing rcc / hume / stoneware / g.i. pipe / surface in existing trench as required. 66 for 415v underground cable from project lake nectar to project synthesis. 67 supply of xlpe insulated power cable ( conforming is 7098 part i ) 1100 volt grade, 1 core / 2 core / 3½ core / 4 core isi marked with alu. stranded / solid conductor4cx300 armoured 68 1.1 kv xlpe / hd cable end termination ( 185 300 sq. mm. 3½ / 4 core ) 69 1.1 kv xlpe / hd cable straight through jointing kit, 300 400 sq. mm. 3½ / 4core 70 supply of approved type cable cover flag stone 200mm width & 32mm to 50mm thick of required length inclusive of transport as required. 71 laying of one number 3 core h.t armoured / unarmoured power cable of grade exceeding 1.1kv but not exceeding 11kv of size not exceeding 300 sq. mm in the existing rcc / hume / stoneware / g.i. pipe / surface in existing trench as required. 72 dp structures for receiving 33 kv incoming at 33kv substation 73 h beams 152 x 152 mm., 37.1 kg. / mtr. 11 mtr. long = 408.1 kg 74 dc.cross arms 8`centre to centre 100x50x6 mm channel ( each weight 56.32 kg ) 75 clamp suitablefor 152 x 152 mm., 37.1 kg. / mtr 13 mtr. long h beam ( each weight 3.2 kg ) 76 horizonatal & cross bracing 8 centre ( wt of eachx bracing 64.29 kg 77 back clamp suitable for h beam ( ms flat 65x8 mm ) each weight 1.92 kg 78 33 kv ( 45kn ) composite polymer disc insulators 79 33 kv strain hardware ( t&c type ) fittings 80 33 kv, 10 kn pincomposite polymer insulator, frp dia 33.5mm 81 stay set 20 mm 82 staywire 7 / 4.00 mm. ( 7 / 8 swg ) 83 clamp suitablefor 152 x 152 mm., 37.1 kg. / mtr h beam ( each weight 3.2 kg ) 84 stone block / pre cast block for base pedding 450x450x75mm 85 concreting ( 1:3:6 ) of h beam @ 0.70 cmt.per pole including base pedding 86 concreting of stay ( 20 mm / 25 mm ) @ 0.3 cmt. per stay 87 earthing coil of 115 turns of 50 mm.dia and 2.5 mtr lead of 4.0 mm g.i wire 88 33kv switchgear:33 kvair insulated switchgearindoor type, extensible type & scada compatible as per iec 62271 200 with following features, compartmentalized modular typesuitable for 36kv 1250a copper busbar with short circuit rating of 31.5ka for 3 sec. 89 incomer:1. 36kv 1250a copper busbar with short circuit rating of 31.5ka for 3 secwith motor operated spring charging mechanism, control circuit suitable for local and remote operation.the breakers shall be trip free and shall have anti pumping feature.2.the 33kv ht panel shall be internally arc tested for 31.5ka for 1 sec duration a flr.necessary type test report for internal arc for 1 sec shall be furnished by the manufacturer. 3.the vacuum circuit breaker shall be rated 1250a for short circuit rating of 31.5ka for 3 sec. the spring charging of the breaker shall be with integral spring charging handle. 4.the vacuum circuit shall be completely enclosed vacuum interruptors in housing of polymer material . 5.the inspection window on the vcb door shall be made of toughened glass only of suiltable strength to withstand the internal arc. 6.the pt fuses shall be completely enclosed in epoxy housing to prevent any flash over occurance. 7.cable termination suitable for current ratings 1rx3cx300 sqmm, . theearthing terminal busbar of size 25x5 mm& ct ratings of 300 150 / 5 5a with cl 1.0 5p10 20va with multifunction meter for metering with line pt 33kv / v3 / 110v / 3 cl 1.0 / ps 20va.8.the ais shall have numerical relay scada compalitble with iec 61850 communication facility suitable for incomer protection / trip ckt supervision / antipumping / lock out relay & accesories for breaker on / off button / mimic diagram / electronic hooter / tnc switch / dc&ac on / off, led lamps for indication on breaker status / live status / necessary panel status &thermostat based anti condensation heater.9. the pannel shall be internal arc tested 31.5 ka for 1 sec. duration a flr provided with gas duct to remove the hot gasses / plasma formedduring internal arc out off the switchgear room.10. the master relay should be both electrical & mechanical reset type. 90 outgoing:1. 36kv 1250a copper busbar with short circuit rating of 31.5ka for 3 secwith motor operated spring charging mechanism, control circuit suitable for local and remote operation.the breakers shall be trip free and shall have anti pumping feature.2.the 33kv ht panel shall be internally arc tested for 31.5ka for 1 sec duration a flr.necessary type test report for internal arc for 1 sec shall be furnished by the manufacturer. 3.the vacuum circuit breaker shall be rated 1250a for short circuit rating of 31.5ka for 3 sec. the spring charging of the breaker shall be with integral spring charging handle. 4.the vacuum circuit shall be completely enclosed vacuum interruptors in housing of polymer material . 5.the inspection window on the vcb door shall be made of toughened glass only of suiltable strength to withstand the internal arc. 6.the pt fuses shall be completely enclosed in epoxy housing to prevent any flash over occurance. 7.cable termination suitable for current ratings 1rx3cx300 sqmm, . theearthing terminal busbar of size 25x5 mm& ct ratings of 300 150 / 5 5a with cl 1.0 5p10 20va with multifunction meter for metering with line pt 33kv / v3 / 110v / 3 cl 1.0 / ps 20va.8.the ais shall have numerical relay scada compalitble with iec 61850 communication facility suitable for incomer protection / trip ckt supervision / antipumping / lock out relay & accesories for breaker on / off button / mimic diagram / electronic hooter / tnc switch / dc&ac on / off, led lamps for indication on breaker status / live status / necessary panel status &thermostat based anti condensation heater.9. the pannel shall be internal arc tested 31.5 ka for 1 sec. duration a flr provided with gas duct to remove the hot gasses / plasma formedduring internal arc out off the switchgear room.10. the master relay should be both electrical & mechanical reset type. 91 buscoupler:1.the aisdesign shall be compartmentalized modular typesuitable for 36kv 1250a copper busbar with short circuit rating of 31.5ka for 3 secwith motor operated spring charging mechanism, control circuit suitable for local and remote operation.the breakers shall be trip free and shall have anti pumping feature.2.the 33kv ht panel shall be internally arc tested for 31.5ka for 1 sec duration a flr.necessary type test report for internal arc for 1 sec shall be furnished by the manufacturer. 3.the vacuum circuit breaker shall be rated 1250a for short circuit rating of 31.5ka for 3 sec. the spring charging of the breaker shall be with integral spring charging handle.4.the vacuum circuit shall be completely enclosed vacuum interruptors in housing of polymer material .5.the inspection window on the vcb door shall be made of toughened glass only of suiltable strength to withstand the internal arc. 6.the pt fuses shall be completely enclosed in epoxy housing to prevent any flash over occurance.7.the cable termination suitable for current ratings 1rx3cx300 sqmm theearthing terminal busbar of size 25x5 mm& ct ratings of 300 150 / 5 5a with cl 1.0 5p10 20va with multifunction meter for metering 8.the ais shall have numerical relay scada compalitble with iec 61850 communication facility suitable for ibuscouplerprotection / trip ckt supervision / antipumping / lock out relay & accesories for breaker on / off button / mimic diagram / electronic hooter / tnc switch / dc&ac on / off, led lamps for indication on breaker status / live status / necessary panel status &thermostat based anti condensation heater.9. the pannel shall be internal arc tested 31.5 ka for 1 sec. duration a flr provided with gas duct to remove the hot gasses / plasma formedduring internal arc out off the switchgear room.10. the master relay should be both electrical & mechanical reset type. 92 11kv switchgear 93 11 kv air insulated switchgearindoor type for power transformeroutgoing extensible type & scada compatible as per iec 62271 200 with following featurs. 1.the aisdesign shall be compartmentalized modular typesuitable for 12kv 1250a copper busbar with short circuit rating of 31.5ka for 3 secwith motor operated spring charging mechanism, control circuit suitable for local and remote operation.the breakers shall be trip free and shall have anti pumping feature.2.the 12kv ht panel shall be internally arc tested for 31.5ka for 1 sec duration a flr.necessary type test report for internal arc for 1 sec shall be furnished by the manufacturer. 3.the vacuum circuit breaker shall be rated 1250a for short circuit rating of 31.5ka for 3 sec. the spring charging of the breaker shall be with integral spring charging handle.4.the vacuum circuit shall be completely enclosed vacuum interruptors in housing of polymer material . 5.the inspection window on the vcb door shall be made of toughened glass only of suiltable strength to withstand the internal arc. 6.the pt fuses shall be completely enclosed in epoxy housing to prevent any flash over occurance.7. theearthing terminal busbar of size 25x5 mm& ct ratings of 600 300 / 5 5a with cl 1.0 5p10 20va with multifunction meter for metering .8.the ais shall have numerical relay scada compalitble with iec 61850 communication facility suitable for incomer protection / trip ckt supervision / antipumping / lock out relay & accesories for breaker on / off button / mimic diagram / electronic hooter / tnc switch / dc&ac on / off, led lamps for indication on breaker status / live status / necessary panel status &thermostat based anti condensation heater.9. the master relay should be both electrical & mechanical reset type. 94 11 kv air insulated switchgear indoor typeforfeeder outgoingextensible type & scada compatible, as per iec 62271 200 with following features . 1.the aisdesign shall be compartmentalized modular typesuitable for 12kv 1250a copper busbar with short circuit rating of 31.5ka for 3 secwith motor operated spring charging mechanism, control circuit suitable for local and remote operation.the breakers shall be trip free and shall have anti pumping feature.2.the 12kv ht panel shall be internally arc tested for 31.5ka for 1 sec duration a flr.necessary type test report for internal arc for 1 sec shall be furnished by the manufacturer. 3.the vacuum circuit breaker shall be rated 1250a for short circuit rating of 31.5ka for 3 sec. the spring charging of the breaker shall be with integral spring charging handle.4.the vacuum circuit shall be completely enclosed vacuum interruptors in housing of polymer material .5.the inspection window on the vcb door shall be made of toughened glass only of suiltable strength to withstand the internal arc. 6.the pt fuses shall be completely enclosed in epoxy housing to prevent any flash over occurance.7. theearthing terminal busbar of size 25x5 mm& ct ratings of 200 100 / 5 5a with cl 1.0 5p10 20va with multifunction meter for metering .8.the ais shall have numerical relay scada compalitble with iec 61850 communication facility suitable for outgoin feederprotection / trip ckt supervision / antipumping / lock out relay & accesories for breaker on / off button / mimic diagram / electronic hooter / tnc switch / dc&ac on / off, led lamps for indication on breaker status / live status / necessary panel status &thermostat based anti condensation heater.9. the master relay should be both electrical & mechanical reset type. 95 11 kv air insulated switchgear indoor typefor bus coupler outgoing extensible type & scada compatible, as per iec 62271 200 with following features.1.the aisdesign shall be compartmentalized modular typesuitable for 12kv 1250a copper busbar with short circuit rating of 31.5ka for 3 secwith motor operated spring charging mechanism, control circuit suitable for local and remote operation.the breakers shall be trip free and shall have anti pumping feature.2.the 12kv ht panel shall be internally arc tested for 31.5ka for 1 sec duration a flr.necessary type test report for internal arc for 1 sec shall be furnished by the manufacturer. 3.the vacuum circuit breaker shall be rated 1250a for short circuit rating of 31.5ka for 3 sec. the spring charging of the breaker shall be with integral spring charging handle.4.the vacuum circuit shall be completely enclosed vacuum interruptors in housing of polymer material . 5.the inspection window on the vcb door shall be made of toughened glass only of suiltable strength to withstand the internal arc. 6.the pt fuses shall be completed enclosed in epoxy housing to prevent any flash over occurance. 7. theearthing terminal busbar of size 25x5 mm& ct ratings of 600 300 / 5 5a with cl 1.0 5p10 20va with multifunction meter for metering .8.the ais shall have numerical relay scada compalitble with iec 61850 communication facility suitable for buscoupler protection / trip ckt supervision / antipumping / lock out relay & accesories for breaker on / off button / mimic diagram / electronic hooter / tnc switch / dc&ac on / off, led lamps for indication on breaker status / live status / necessary panel status &thermostat based anti condensation heater.9. the master relay should be both electrical & mechanical reset type. 96 11kv bus pt panel with necessary bus pt formetering & protection 11kv / v3 / 110v / v3 / 110v / 3 cl 1.0 cl ps 50 va .epoxy enclosed pt fuses shall be mounted on bus pt. the fuses shall have fuse failure protection / necessary led lamps for indication to be provided.numercial relay scada compatible for uv / ov protection with iec 61850 protection to be provided 97 transformer, 33 / 0.4 kv 3 phase 98 supplying, installing, testing and commissioning of 33 / 0.4 kv 3 phase 50 cycle oil immersed, naturally cooled, outdoor type transformer connected delta on h.t. side and star on l.t. side, hand operated off load tap changer switch above 100 kva, rating and diagram plate, two earthing terminal, lifting lugs, oil level gauge, drain valve with plug, temperature not exceeding 50ºc on load, oil conservator with drain plug, oil filling hole with plug, dehydrating silica gel breather on eye level, four unidirectional roller, arcing horns, explosion vent, terminal arrangement bushing on h.v. side and cable box on lv side, first filling of oil upto desired level and transformer installing on existing structure with all required materials arrangement as required isi marked & as per is specification.energy efficiency level 3, 200 kva 99 lighting system 100 supply and fixing of surface mounting type led light fixture, led of 1 to 3 watt each assembled on single mcpcb, having color temp upto 6500k & having 50000 burning hrs. life with minimum @ l 70, system lumen output should be minimum with efficacy>100 lm / watt. led driver, pf> 0.95, thd < 20% & surge protection 4kv. the colour rendering index of led light should be more than 70. housing made of crca powder coated frame with glare free diffused polycarbonate cover. submission lm 79 08 / is16106 ( 2012 ) , iec60598, iec61347i / c connection wire, testing etc. to complete the job.led luminiare 2 x 2, 45watt, color temp 3000 6500k as required. 101 supply and fixing led tube rod comprising of led tube with non integral / integral driver, upto 6500k color temp having 40000 burning hrs life with minimum @ l 70, system lumen output should be minimum with system efficacy> 100 lm / watt. led driver pf> 0.95 & thd < 20%. the colour rendering index of led light should be more than 70. submission lm 79 08 / is16106 ( 2012 ) , iec60598, iec61347i / c connection wire, testing etc. to complete the job. tube light led 1 x 20 / 22watt, integral i / c batten aluminium body, pc diffuser. 102 supply and fixing street light with high power led of 3 to 6 watt each on existing bracket assembled on single mcpcb and additional unique peanut lens on each led, system lumens output with efficacy>120 lm / watt. luminiare having color temp upto 6500k & 50000 hrs. burning life with minimum @ l 70, the colour rendering index of led light should be more than 70. luminiare comprises of driver, pf> 0.95 & surge protection 10kv. housing made of pressure die cast aluminium with heat resistant flat glass, ip65 protection. submission lm 79 08 / is16106 ( 2012 ) , iec60598, iec61347 i / c connection wire, testing etc. to complete the job. 120watt, color temp 3000 6500k as required 103 supply and fixing street light with high power led of 3 to 6 watt each on existing bracket assembled on single mcpcb and additional unique peanut lens on each led, system lumens output with efficacy>120 lm / watt. luminiare having color temp upto 6500k & 50000 hrs. burning life with minimum @ l 70, the colour rendering index of led light should be more than 70. luminiare comprises of driver, pf> 0.95 & surge protection 10kv. housing made of pressure die cast aluminium with heat resistant flat glass, ip65 protection. submission lm 79 08 / is16106 ( 2012 ) , iec60598, iec61347 i / c connection wire, testing etc. to complete the job. 40watt to 48watt, color temp 3000 6500k as required. 104 point wiring :point wiring ( excluding metallic switch box & sheet but including switches, sockets, lamp holders / ceiling roses etc ) with 1.5sq. mm. pvc insulated cable frls with copper multi strand conductor isi marked in surface rigid p.v.c. conduit ( mms ) isi marked of suitable size and 1.5sq. mm. pvc frls insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for 105 light point / fan points. 106 primary short point 107 primary medium point 108 primary long point 109 ( light point / fan points ) looping point 110 secondary short point 111 secondary medium point 112 secondary long point 113 3 pin 6 amp socket outlet on separate board 114 short point 115 medium point 116 long point 117 supplying and fixing 25mm pvc conduit isi marked frls along with accessories on surface etc. as required 118 supplying and fixing factory fabricated hot dip galvanized switch box for normal flush type accessories of minimum 1.2 mm thickness for up to 200mmx250mm size boxes and 1.6mm minimum thickness for higher size boxes, earth terminal stud with nut and washer, including 3 mm thick synthetic phenolic resin bonded laminated sheet conforming to grade p i of is:2036 1974 on surface / concealed including all necessary accessories, painting etc. as required as per specification:ms box 200 mm x 150 mm x 60 mm 119 supply and fixing of 9w, rechargeable inverter led bulb rechargeable inverter led bulb, reduces to 40 50% ( emergency application ) with lithium ion battery 2600mah, backup upto 5 hrs. having color temp upto 6500k, ip 20 rating, thd ( total harmonic distortion ) <20% 120 415v switchgear 121 pcc panel 122 supply, fixing, testing & commissioning wall / floor mounted lt panel primer coated with powder coated paint & provided with required gasket for dust / vermin proof with degree of protection ip42 suitable for 415volt 3 phase, 50 hz, 4 wire system fabricated out of crca sheet upto 2 mm thick ( 1.6 mm for doors ) duly compartmentalized for incomer, bus section, outgoings, cable alleys & ct, pt ampere metre, volt metre, selector switches, frequency metre, phase indicating lamp, energy metre complete including cost of busbar supports, detachable cable gland plates, 2 earthing terminals, internal wiring & fixing of separately supplied mcbs, mccbs, acb, panel mounted changeover switch / sfus, etc. as required but excluding cost of busbar strips, ampere metre, volt metre, selector switch as per approved design 123 400a mccb ( incomer ) mccb 36ka current rating 400 amps 4 pole μ processor release, over load 40% 100% x in. & short circuit 1.5 8 x ir. adjustable 124 outgoing: mccb 25ka current rating 40 & 100 amps 4 pole & micro processor release, over load 40% 100% x in. & short circuit 1.5 8 x ir. adjustable 125 mccb 25ka current rating 160 amps 4 pole & micro processor release, over load 40% 100% x in. & short circuit 1.5 8 x ir. adjustable 126 led lamp indicator 127 digital ampere metre with cts with selector switch 128 digital volt metre with selector switch & hrc fuse 129 aluminium bus bar strips with pvc sleeves 130 supplying and fixing of ct 1a / 5a as per site selectable busbar dimension of approved make in existing main panel for power factor panel including connections etc. as required as per specification. 131 415v capacitor panel 132 supply, fixing, testing & commissioning wall / floor mounted lt panel primer coated with powder coated paint & provided with required gasket for dust / vermin proof with degree of protection ip42 suitable for 415volt 3 phase, 50 hz, 4 wire system fabricated out of crca sheet upto 2 mm thick ( 1.6 mm for doors ) duly compartmentalized for incomer, bus section, outgoings, cable alleys & ct, pt ampere metre, volt metre, selector switches, frequency metre, phase indicating lamp, energy metre complete including cost of busbar supports, detachable cable gland plates, 2 earthing terminals, internal wiring & fixing of separately supplied mcbs, mccbs, acb, panel mounted changeover switch / sfus, etc. as required but excluding cost of busbar strips, ampere metre, volt metre, selector switch as per approved design 133 supplying and fixing of capacitor duty contactor of approved make in existing power factor / lt panel including connections etc.as required as per specification. 134 for 25 kvar 440v, 3ph, 50hz, aux contact 1no 135 for 15 kvar 440v, 3ph, 50hz, aux contact 1no 136 for 5 kvar 440v, 3ph, 50hz, aux contact 1no 137 supplying and fixing of apfc relay 1a / 5 a site selectable, measurement of individual current and voltage harmonic ( thd ) , capacitor failure indication, inbuilt temperature sensor of approved make in existing power factor panel including connections etc. as required as per specification as mentioned below 138 8 step apfc relay ( 144 x144mm ) 139 wall mounted db 140 supplying of approved make tpn mcb db metal double door ip 43 protection with provision for fp mcb / isolator / rccb / rcbo as incomer and sp mcbs as outgoing inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per is:13032 ( exclusive of mcb & isolator ) :6 way ( 8+18 ) 141 supplying and installing of rcbos ( residual current circuit breaker with overload and short circuit protection ) isi marked complete as per i.s. standard conforming to iec:61009 1 & is:12640 2, 240 / 415v 50 hz with 10 ka short circuit withstand capacity for earth leakage, overload & short circuit protection including connection in existing enclosure in approved manner as per specification.4 pole 40a, 30ma 142 mcb sp 6amp to 32amp 10ka rating 143 acdb 144 acdb415 v, along withthree phase neutral voltmeter, three phase ammeter andselector switches, 1no.200 amps tpn switch fuse unit as incomer, 1no. 63 amp.tpn mccb switches as outgoing feeders & 2no. 32 amp. mccb as outgoingfor yard and control room lightining and 6 no. 16 no. mccb for control panels, each incoming & outgoing shall have indicating lamp. including 20% spare 145 earthing system 146 earthing with g.i. earth pipe 4.5 metre long and 40 mm dia with masonry encloser in cement mortar, cover plate having locking arrangement on the top etc. ( but without charcoal or coke and salt ) complete as required 147 earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories and providing masonry encloser in cement mortar, cover plate having locking arrangement on the top and g.i. watering pipe 20mm dia 2.7 metre long etc. ( but without charcoal or coke and salt ) complete as required 148 supply and layingg.i. wire at 0.5 metre below ground level as conductor earth electrode including jointing etc. as required. 149 4.0mm ( 8 swg ) dia. 150 4.87mm 6 swg g.i. 151 25mm x 5mm g.i. strip 152 25mm x 6mm g.i. strip 153 50mm x 6mm g.i. strip 154 lightning protection system 155 providing and fixing of lightning conductor finial made of 18mm dia 500mm long bright nickel plated copper tube tapered having single prong at top with bright nickel plated brass base m10 for connection and intersection of flat or round conductor including holes, clamp complete as required. 156 fixing of lightning conductor finial made of 25mm dia 300mm long copper tube / g.i. tube having single prong at top with base plate etc. complete as required. 157 riveting / sweating and soldering of copper / g.i. tape ( with another copper / g.i. tape, base of finial or anyother metallic object ) as required 158 providing and fixing copper tape 20mm x 3mm thick on parapet and surface of wall of lightning conductor as required ( for horizontal runs ) 159 providing and fixing copper tape 20mm x 3mm thick on parapet and surface of wall of lightning conductor as required ( for vertical runs ) 160 providing and fixing testing joint made by 20mm x 3mm thick copper strip 125mm long with 4 nos of tinned brass bolts, nut, check nuts and spring washers etc. complete as required. 161 providing and laying copper tape 32mm x 6mm thick for earth electrode directly in ground as required 162 laying of copper tape 32mm x 6mm thick for earth electrode directly in ground as required 163 earthing:with 3 metre g.i. pipes having outer pipe dia of 50mm having 80 200 micron galvanizing, inner pipe dia. of 25mm having 200 250 micron galvanizing, connection terminal dia. of 12mm in nominal soil with 50 kg ( two bag ) back filling bentonite compound ul listed and confirm to relevant international / indian standards around electrode upto ground level. 164 cabling system 165 for 11kv underground cable from 33 / 11kv transformer 1 & 2 to 11kv panel 166 3 core xlpe cable 11 kv grade, high tension xlpe cable, 3 core 300 sq.mm armoured al. conductorsupply of approved high tension xlpe cable ( conforming is 7098 / ii / 85 ) as per isi standard 3 core armoured with alu. solid / stranded conductor isi marked as required 167 termination kit 11 kv xlpe cable o.d. termination, 3 x 240 400 sq. mm 168 supply of approved type cable cover flag stone 200mm width & 32mm to 50mm thick of required length inclusive of transport as required. 169 laying of one number 3 core h.t armoured / unarmoured power cable of grade exceeding 1.1kv but not exceeding 11kv of size not exceeding 300 sq. mm in the existing rcc / hume / stoneware / g.i. pipe / surface in existing trench as required. 170 supply of xlpe insulated power cable ( conforming is 7098 part i ) 1100 volt grade, 1 core / 2 core / 3½ core / 4 core isi marked with alu. stranded / solid conductor, xlpe insulated power cable, al. conductor 171 4 core armoured, 300 sq. mm. 172 4 core armoured, 6 sq. mm. 173 supplying and fixing heavy duty cable gland 174 4 core armoured, 300 sq. mm. 175 4 core armoured, 6 sq. mm. 176 supplying and fixing crimping type alum. lugs as per i.s.s. specification suitable for following size of cable with alu. / copper solid / stranded conductor evenly crimped with high / pressure tool and connected to switch gear / bus / m.c.c.b. / m.c.b. etc. as required complete. 177 4 core armoured, 300 sq. mm. 178 4 core armoured, 6 sq. mm. 179 laying of one number armoured / unarmoured power cable 1.1kv grade of size not exceeding 25 sq. mm direct in ground including excavation in all soil / murrum / soft rock, sand cushioning, protective covering and refilling the pit etc. as required. 180 supply and erection of hot dip g.i. cable tray perforation not more than 17.5% for specific dimensions along with tees, bends. the cable tray shall be hang from ceiling / fixed to wall with necessary angle / flat iron / hanging rod, for ceiling suspensions, clamp, anchor fastener, nuts, bolts, washers, not more than 1.0 mtr. apart complete as per specification to complete the job. the tray 181 600 x 50 x 2 mm thick 182 300 x 50 x 1.6mm thick 183 450 x 50 x 2 mm thick 184 control cables 185 copper control cable 12 core, 2.5 sqmm pvc unarmored 186 copper control cable 8 core, 2.5 sqmm pvc unarmoured 187 copper control cable 4 core, 2.5 sqmm pvc unarmoured 188 copper control cable 2 core, 2.5 sqmm pvc unarmoured 189 cabletranch of 1.5 mtr wide, 1.75 mtr depth with four layer cable laying tray supported by wall mount angles with precast rcc trench cover, water stop, brick work wherever required including cement, reinforced steel, steel angle, flats, frame work cable tray, excavation etc. 190 battery system 191 110 volt, 100ah battery 192 battery charger230 vacinput suitable for 110 volt, 100ah battery 193 direct curent distribution board ( dcdb ) 24 volts indoor floor / wallmounted comprising of 1 no. 2p / 100a dc mccb 5a switch fuse unit as incommer and 8 no. 2p / 40a mccb 5a switch fuse units for each individual outgoing circuit of indoor control panels, indoor / outdoor vcb panels, 1 no. 2p / 40a mccb 5a switch forcontrol room emergency dc lighting including 20% as spare. each incoming & outgoing shall have indicating lamp, 194 safety equipments 195 supplying & fixing of fire extinguisher / refills as per is specification abc type duly refilled 6 kg & ready to use 196 4 buckets set with sand, self supported m.s. stand i / c shed duly painted with red colour as per is. 197 supply of rubber mat 2 x 1.0mtr, 1100v tested 198 supply of hand gloves 33kv tested 199 supply of first aid box complete with medicine & bandage as per specification 200 supply of shock instruction chart duly framed with glass, as reqd. 201 supply and fixing as per specification caution / danger board of approved make with necessary material complete.small size 200 x 150 mm for mv / lt 202 scada part a software prortion 203 remote terminal unit 204 multi function transducer ( 5 amp, 110 v with rs485 modbus communication protocol 205 contact multiplying relays ( cmrs ) 206 heavy duty relay ( hdr ) for cb trip / close ( 48v dc, 2 no, 1 nc ) 207 ldms 208 laser printer 209 ldms software 210 48 v dc power supply ( dcps ) system based on smps 211 router 230 v ac, 2 ge ports, 48xfe, wan speed 200 mbps 212 2 mbps vpn link for connectivity of s / s with scada control center. 213 2kva ups ( for ldms ) with 160 ah, 72 v battery set 214 cat 6 cable 215 scada part b hardware equipment 216 contactors 30 v dc, 10 amp 217 tap position indicator transmitter 218 windingtemperature indicator ( wti ) , dial 150mm , with capilary, mercury swicth type 219 oil temperature indicator ( oti ) , dial 150mm , with capilary, mercury swicth type 220 electromechanical isolator contacts 221 copper control cable 8 core, 2.5 sqmm pvc unarmored 222 copper control cable 4 core, 2.5 sqmm pvc unarmoured 223 copper control cable 2 core, 2.5 sqmm pvc unarmoured 224 rtu base and foundation ( base should be capable of withstanding 200 kg load ) 225 furniture for control roomtable 600mmx 900mm 1no., chair 3no., computer table 1no. ( godrej or equivalent ) 226 ac for scada room:supply, installation, testing and commissioning of split type wall mounted air conditioning unit of following capacity including indoor, outdoor unit fitted with inverter based rotary compressor, copper condenser and first charge refrigerant r410a. the condensing unit working range should be capable for providing cooling between + / 5 deg. c to 50 deg. c & heating within 0 deg. c to 15 deg. c including connection of copper pipe of required size upto 3 mtr., insulation, cordless remote control, auto air swing louvers, wall stand for outdoor unit, connection copper lead wire, condensed water outlet pipe 2 mtr. complete etc as required. outdoor / indoor units should be of same make ( brand ) . 1.8 / 2 tr star rating 3 star 227 civil work 228 fencing of s / s land with barbed wire 229 yard fencing with chain link mesh over rcc beam 230 ms main andwicket gate on rcc column 231 ms sign board, bay indication board & ryb phase indication board 232 design, engineering and construction of control room building including indoor cable trench / duct / tray comprising of battery room, panel room, office room, toilet etc as required, minimum 30mx20m size for accomodating 33kv & 11kv ais panels & control pannels, 415v panels, scada / control room, toilet, battery bank, capacitor bank, ) or as per available land including supply of construction materials, labour, cement, reinforcement steel, frame work, excavation etc, all complete as per detailed technical specification, approved drawing & scope of works. 233 procedure to avoid grass in sub station yard black cotton. by laying stone cursher dust. base rates combined for both the layers detailed in ( e 1 ) and ( e 2 ) in civil stock. 234 approach road ( wbm ) with hume pipe culvert 235 approach road ( rcc with ratio 1:2:4 ) from main gate to power transformer foundation, size ( 20x3 ) mtr 236 approach road , made by 60 mm thick factory made cement concrete paver block of m 30 grade, along the cable trenches upto various equipments in the yard 237 60 mtr. deep 150 mm dia tube well 238 additional digging ( if required ) 150 mm dia tube well including casing beyond 60 mtr 239 1000 liter p / f sintex overhead tank & gi pipe ( with length of 125 mtrs ) fitting for water supply including providing water tap ( 17 no. ) near transformer neutral earthing 240 providing and fixing 5hp submersible pump 241 providing & fixing perforated cable tray 300 mm wide & 2 mm thick fixed on 45x45x5 mm m.s. angle stand grouted in c.c 1:24 242 providing and fixing earth pit of brick massonery 0.6 x 0.6 m inner size with flag stone cover for watering system for 18 no earth pits 243 fire extinguisher cartridge co2 10 kgs 244 construction of retaining wall 1.5 m high as per site requirement 245 ventilation for control bldg ( other than scada room ) :supplying, erecting and testing of approved make exhaust fan heavy duty with mounting frame, blades ac 230 250 complete connection and including, frame bolt / anchor hole fasteners etc. complete finished and asrequired.450mm sweep rpm 900 / 1400 246 cctv 247 supply, installation testing and commissioning of outdoor wdr ir rugged ip dome cameras shall be equipped with 1 / 2.7 or 1 / 2.8 2 mpprogressive scan imager or 1 / 3 4 mp progressive scan imager to capture 1080p resolution at25 / 30 fps or 4 mp at 20 fps images, 2.7–12 mm or 7–22 mm, f1.4, motorized focus / zoom len, h.264 and mjpeg codec, triple stream support, 50 m ( 150’ ) ir distance, depending on scene reflectance, waterproof ( ip67 ) and ik10 vandal resistant camera housing, onvif profile s and g compliant, built inpoe ( power over ethernet ) eliminates, separate power supply and associated wiring, 24 v ac / 12 v dc inputs where poe power is unavailable, supports up to 128 gb micro sdhc ( class 10 ) card for local video storage when network is interrupted. card not included. 248 supply, installation testing and commissioning of 32 channel nvr with 1080p real time live view h.265 / h.264 mjpeg dual codec decoding up to 12 mp resolution preview & playback max 320 mbps incoming bandwidth support 4 sata hdds up to 32tb, supports fisheye video de warping in local and web user interface, supports visual or auditory notifications ( a flashing light, bell, or siren ) complete with ul certification 249 supply, installation testing and commissioning of 24 port poe switch with 4 sfp ports, having security features like port security supports 64 macs per port, auto surveillance vlan, loopback detection automatically disables a port when a loop is detected, cable diagnostics allows administrators to determine cable status, utp cat. 5, cat. 5e ( 100 m max. ) , full / half duplex for 10 / 100 mbps, full duplex for 1000 mbps, auto mdi / mdix adjustment for all twisted pair ports, switching capacity, 56 gbps, maximum 64 bytes packet forwarding rate, 41.7mbps, ports 1 to 24 compliant with 802.3 at 250 workstation with client licensethe work station shall have the following specifications: processor intel @ i5 750 2.66 ghz with internal memory of 4 gb ram. operating system window 7professional 64 bit ( wow 64mode ) or window 7 professional 32 bit nvidia 1 gb independent graphic card. resolution support for cameras 2560x1600 display resolution capable and direct x true colour 32 bit. dual link vdi outputs. clientsoftware shall support dual monitors each displaying 16 cameras simultaneously. a maximum of 32 cameras viewing per workstation at a time.programmable to sequence. 251 cctv colour monitorsupply, installation, testing and commissioning of 32 flat led colour monitors. 252 hard disk providing &fixing of 4 tb hard disk 253 epabx system 254 supply, installation, testing and commissioning of epabx system consist, no. of extension, no of junction, no. of expandable eport, operating console, current on max. load with isdn compatible of approved make and labor as required as per specifications.epabx system consists of 48 nos. extensions, 8 nos of junction & upto 96 nos. of expandable eport, with one operating console, 2 amp max. current 255 float cum boost chargersupplying & fixing float cum boost charger for epabx system of approved make with all necessary material as required as per specifications. 25 amp 48 v float cum boost charger 256 supplying, fixing essential additional accessories to epabx system of approved make with all necessary material as required as per specifications. 257 epabx e 1 card 258 epabx system digital phone with 2 line display ( 32 characters ) with 8 programmable keys. 259 epabx system digital line card 8 line 260 discom supervision charges...

Madhya Pradesh Power Transmission Company Limited - Madhya Pradesh

31084347 procurement of ehv grade i transformer oil procurement of ehv grade i transformer oil , electrical items : , ehv grade i transformer oil for power transformers conforming to all technical particulars as detailed out in annexure i ( volume ii ) attached. the oil should be supplied in road tankers with nitrogen cushioning under positive pressure , ( b ) structure for item 3 ( a ) above , ( a ) 36 kv gapless lightning arrester with terminal connector meeting the technical requirement as per section – iii, annexure iii , ( b ) structure for item 4 ( a ) above , ( a ) 33 kv isolator with earth switch complete with insulators & all accessories meeting the technical requirement as per section – iii, annexure iv , ( b ) structure for item 5 ( a ) above , 33 kv vacuum circuit breaker with structure meeting the technical requirement as per section – iii, annexure v , 33 kv control & relay panel meeting the technical requirement as per section – iii, annexure vi , 33 kv bolted type post insulator structure complete with 33 kv post insulators meeting the technical requirement as per section – iii, annexure vii...

Madhya Pradesh Power Generating Company Limited - Madhya Pradesh

31071582 procurement of l and t make electrical feeder / panel spares of travelling tippers and auxiliaries for 2x600 mw, ph i, sstpp, mppgcl, dongalia procurement of l and t make electrical feeder / panel spares of travelling tippers and auxiliaries for 2x600 mw, ph i, sstpp, mppgcl, dongalia , dc power contactor , ac1 rating: 65 amp, coil voltage: 220 vdc type: mdx65 cat no: cs91585 , add on block , 10 amp, 230 vac contact arrangement: ( 3no+1nc ) cat no: cs94113 , 10 amp, 230 vac contact arrangement: ( 4no ) cat no: cs94112 , 10 amp, 230 vac contact arrangement: ( 2no+2nc ) cat no: cs94114 , control relay ( auxiliary contactor ) , type: mx0 40e ( 4no ) contact arrangement: ( 4no ) coil voltage: 220 vdc , type: mx0 31e ( 3no+1nc ) contact arrangement: ( 3no+1nc ) coil voltage: 220 vdc , type: mx0 22e ( 2no+2nc ) contact arrangement: ( 2no+2nc ) coil voltage: 220 vdc , type: mx0 13e ( 1no+3nc ) contact arrangement: ( 1no+3nc ) coil voltage: 220 vdc , type: mx0 04e ( 4no ) contact arrangement: ( 4no ) coil voltage: 220 vdc , thermal overload relay , current setting: ( 30 60 ) amp, cat no: ss94141oogo , current setting: ( 0.9 1.5 ) amp, cat no: ss94141oomo , current setting: ( 4.5 7.5 ) amp, cat no: ss94141oouo , switch fuse unit , tpn sfu 32 a cat no: fnx 32 , tpn sfu 63 a cat no: fnx 63 , tpn sfu 100 a cat no: fnx 100 , tpn sfu 125 a cat no: fnx 125 , tpn sfu 200 a cat no: fnx 200...

South Eastern Coalfields Limited - Madhya Pradesh

30987244 bids are invited for 50.05.00 vcb shunt trip coil , bossabwna cp primary side p.t fuse plate wiring assembly , htcp2 h.t. control plate wiring assembly , dcpp dc power pack , bobp3 bullet pin 3.3kv , htptl1 potential tranformer 3.3kv , 50.10.00 vcb closing coil , nrmr neutral monitoring relay with resitance , bokudf4 fuse terminal , boabwna hrc ht pt fuse , mcra022a7 aux. contactor, htta3.3 ht bushing , bobc brass cone , t33 ht bushing, boarc vcb aux. rotary switch , vulcan vacuum circuitbreaker , kie/3.3 isolator 400a , heat heater , botp6 mcb ,raptor capacitor trip device , boplaco2 control relay ,vm/so65 voltmeter , bossr overload short circuit relay ,bolso vcb limit switchboq title mine line make spares total quantity : 101...

Madhya Pradesh Madhya Kshetra Vidyut Vitaran Company Limited - Madhya Pradesh

30859280 estimate for bifurcation of existing 11 kv kharai pump feeder from 33 / 11 kv s / s kharai under kolaras r d / c onm dn ii shivpuri 1 140 kg, 8. mtrs. longpcc pole 2 ( labour charge ) 140 kg, 8 mtrs. longpcc pole 3 h beams 152x152 mm. 37.1 kg / meter 9 meter long 4 ( labour charge ) h beams 152x152 mm. 37.1 kg / meter9 meter long 5 aaac raccoon conductor 0.075 sq.inch ( 80 sq.mm. al.eq. ) 6 ( labour charge ) aaac raccoon conductor 0.075 sq.inch ( 80 sq.mm. al.eq. ) 7 11 kv composit polymer disc insulator 8 ( labour charge ) 11 kv composit polymer disc insulator 9 11 kv strain hardware ( t&c type ) fittings 10 ( labour charge ) 11 kv strain hardware ( t&c type ) fittings 11 d.c. cross arms 8 channel ( 100x50x6mm ) 12 ( labour charge ) d.c. cross arms 8 channel ( 100x50x6mm ) 13 11 kv top clamp 65x65x6 mm. angle type 14 ( labour charge ) 11 kv top clamp 65x65x6 mm. angle type 15 aaac dog conductor 0.10 sq.inch ( 100 sq.mm. al.eq. ) 16 ( labour charge ) aaac dog conductor 0.10 sq.inch ( 100 sq.mm. al.eq. ) 17 33 kv ab switch 600 amp with complete accessories. 18 labour chargefor fixing of 33 kv ab switch 600 amp with complete accessories. 19 copper control cable 12 core. 2.5 sq.mm. ( unarmoured ) 20 labour charge forcopper control cable 12 core. 2.5 sq.mm. ( unarmoured ) 21 copper control cable 8 core. 2.5 sq.mm. ( unarmoured ) 22 labour charge forcopper control cable 8 core. 2.5 sq.mm. ( unarmoured ) 23 copper control cable 4 core. 2.5 sq.mm. ( unarmoured ) 24 labour charge forcopper control cable 4 core. 2.5 sq.mm. ( unarmoured ) 25 3ph 4w 3x63.5v lb=5a imax=10a, ht trivector meter, 0.5s, ( for s / s metering ) 26 labour charge for installation of 3ph 4w 3x63.5v lb=5a imax=10a, ht trivector meter, 0.5s, ( for s / smetering ) 27 11kv / 110v, ct / pt 200 100 / 5 amp, outdoor oil immersed type 28 labour charge for installation of 11kv / 110v, ct / pt 200 100 / 5 amp, outdoor oil immersed type 29 9 kv gapless type ( 5 ka ) polymer lightening arrestor 30 labour charge for 9 kv gapless type ( 5 ka ) polymer lightening arrestor with earthing ( set of 3 no ) 31 m.s.flat 50x6mm 32 ( labour charge ) m.s.flat 50x6mm 33 11 kv control & relay panel with numerical static relay for 2 feeder protection 34 labour charge for installation of 11 kv control & relay panel with numerical static relay for 2 feeder protectionincluding stand of suitable size 35 33 kv composite polymer disc insulators 36 labour charge for fixing of 33 kv composite polymer disc insulators 37 33 kv strain harware ( t&c type ) fitting 38 labour charge for 33 kv strain harware ( t&c type ) fitting 39 11 kv.c.ts. ( outdoor dry type ) 200 100 / 5 amps 40 labour charge for handaling & installation of11 kv.c.ts with earthing arrangment . ( outdoor dry type ) 200 100 / 5 amps 41 11 kv vcb, outdoor porcelain clad type with complete structure and accessories for 33 / 11 kv feeder and transformer control 42 labour charge for installation of 11 kv vcb, outdoor porcelain clad type with complete structure and accessories for 33 / 11 kv feeder and transformer control 43 11 kv v cross arm 65x65x6 mm. angle type 44 ( labour charge ) 11 kv v cross arm 65x65x6 mm. angle type 45 11 kv polymer pin insulator 46 ( labour charge ) 11 kv polymer pin insulator 47 p&f perfo cable tray 300 wide, 2 thick fix 45x45x5 ms angle grouted cc 1:24 48 concreting of structures & foundation ( 1:3:6 ) 49 ( labour charge ) concreting of structures & foundation ( 1:3:6 ) 50 concreting of foundation of vcb ( 1:3:6 ) @ 3.5 cmt per vcb plinth 51 labour charge forconcreting of foundation of vcb ( 1:3:6 ) @ 3.5 cmt per vcb plinth 52 t clamp for 33 kv &11 kv bussubstation 53 labour charge for t clamp for 33 kv &11 kv bussubstation 54 marshelling box with 10 no. connectors 55 labour charge formarshelling box with 10 no. connectors 56 sheet metal meter box suitable for h.t. static travector meters with ttb 57 labour charge forfor fixing of sheet metal meter box suitable for h.t. static travector meters with ttb 58 stay set complete without stay wire 16 mm ( painted ) 59 ( labour charge ) stay set complete without stay wire 16 mm ( painted ) 60 stay gi wire 7 / 3.15mm ( 7 / 10 swg ) 61 ( labour charge ) stay gi wire 7 / 3.15mm ( 7 / 10 swg ) 62 g.i. wires 4.0 mm ( 8swg ) 63 ( labour charge ) g.i. wires 4.0 mm ( 8swg ) 64 concreting of stay ( 16 mm / 12 mm ) @0.2 cmt. per stay 65 ( labour charge ) concreting of stay ( 16 mm / 12 mm ) @0.2 cmt. per stay 66 concreting of pcc poles @.03 cmt ( cubic metric ton ) per pole 67 ( labour charge ) concreting of pcc poles @0.3 cmt ( cubic metric ton ) per pole 68 concreting of rail pole / hbeam support @0.56 cmt per pole including muffing of pole 69 ( labour charge ) concreting of rail pole / hbeam support @0.56 cmt per pole including muffing of pole 70 m.s.nuts and bolts 71 earthing coil of 115 turns of 50 mm dia and 2.5 mtr. lead of 4.0 mm g.i. wire 72 earthing for pcc pole 4.00 mm 8 swg g.i wire .8 kg per pole 73 clamp for 140 kg pcc pole ms flat 50x6 mm 74 ( labour charge ) clamp for 140 kg pcc pole ms flat 50x6 mm 75 back clamp for 140 kg pcc pole ms flat 50x6 mm 76 ( labour charge ) back clamp for 140 kg pcc pole ms flat 50x6 mm 77 back filling of poles with boulders 1 78 ( labour charge ) back filling of poles with boulders 79 h beam clampms flat ( 65x8 mm ) 80 ( labour charge ) back clamp for 140 kg pcc pole ms flat ( 50x6 mm ) 81 sgst @ 9% 82 cgst @ 9%...

Madhya Pradesh Power Generating Company Limited - Madhya Pradesh

30848839 procurement of m / s c and s make 415v, lv switchgear spares for 210mw atps mppgcl chachai , 16 a, 415v, 3 pole power contactorcoil voltage 240v ac, make c&sitem code lc1 d173 , 25 a , 415v, 3 pole power contactorcoil voltage 240v ac, make c&sitem code lc1 d253 , 32 a, 415v, 3 pole power contactorcoil voltage 240v ac, make c&sitem code, ( lc1 d323 ) , 40 a415v, 3 pole power contactorcoil voltage 240v ac, make c&sitem code ( lc1 d403 ) , 63 a, 415v, 3 pole power contactorcoil voltage 240v ac, make c&sitem code ( lc1 d633 ) , 80 a, 415v, 3 pole power contactorcoil voltage 240v ac, make c&sitem code lc1 d803 , 115 a 415v, 3 pole power contactorcoil voltage 240v ac, make c&sitem code , lc1 fdp115a , c&s 150 a 415v, 3 pole power contactorcoil voltage 240v ac, make c&sitem code, lc1 fdp150a , 185 a, 415v, 3 pole power contactorcoil voltage 240v ac, make c&sitem code lc1 fdp185a , 225 a, 415v, 3 pole power contactorcoil voltage 240v ac, make c&sitem code, lc1 fdp225a , 400 a, 415v, 3 pole power contactorcoil voltage 240v ac, make c&sitem code, lc1 fdp400a , direct mounting thermal overload relay, with relay range ( 0.10 0.16 ) a, item code:lr1 d09301, make c&s , direct mounting thermal overload relay, with relay range ( 0.63 1.00 ) a, item code:lr1 d09305, make c&s , direct mounting thermal overload relay, with relay range ( 1.00 1.60 ) a, item code:lr1 d09306, make c&s , direct mounting thermal overload relay, with relay range ( 1.60 2.50 ) a, item code:lr1 d09307, make c&s , direct mounting thermal overload relay, with relay range ( 2.50 4.00 ) aitem code:lr1 d09308, make c&s , direct mounting thermal overload relay, with relay range ( 4.00 6.00 ) a, item code:lr1 d09310, make c&s , direct mounting thermal overload relay, with relay range ( 5.50 8.00 ) a, item code:lr1 d09312, make c&s , c&s make direct mounting thermal overload relay with relay range ( 10 13 ) a, item code:lr1 d12316 , c&s make direct mounting thermal overload relaywith relay range ( 13 18 ) a, item code:lr1 d16321 , c&s make direct mounting thermal overload relaywith relay range ( 18 25 ) a, item code:lr1 d25322 , direct mounting thermal overload relay, with relay range ( 23 32 ) a, item code:lr1 d32353, make c&s , direct mounting thermal overload relay, with relay range ( 28 40 ) a, item code:lr1 d32355, make c&s , direct mounting thermal overload relay, with relay range ( 48 57 ) a item code:lr1 d63359, make c&s , direct mounting thermal overload relay, with relay range ( 57 66 ) a, item code:lr1 d63361, make c&s , independent mounting thermal overload relay, with relay range ( 65.0 105 ) a, item code:lr1 f105, make c&s , independent mounting thermal overload relay , with relay range ( 80 125 ) a, item code:lr1 f125, make c&s , independent mounting thermal overload relay, with relay range ( 100 160 ) a, item code:lr1 f160, make c&s , independent mounting thermal overload relay, with relay range ( 160 250 ) a, item code:lr1 f250, make c&s , independent mounting kit for thermal overload relay with relay range item code:la7 d0964, make c&s , independent mounting kit for thermal overload relay with relay range item code:la7 d3264, make c&s , independent mounting kit for thermal overload relay with relay range item code:la7 d4054, make c&s , main contact for 115a, 3p contactor, m / s c&s make item code. la5 ff431hca ( f115 ) , main contact for 150a, 3p contactor, m / s c&s make item code. la5 ff431hca ( f150 ) , main contact for 185a, 3p contactor, m / s c&s make item code. la5 fg431hca ( f185 ) , main contact for 225a, 3p contactor, m / s c&s make item code.la5 fg431hca ( f225 ) , main contact for 400a, 3p contactor, m / s c&s make item code. la5 f400803hca ( f400 ) , 2p, 32 amp, bolted type switch disconnector fuse unit item code: cssdf32b2, make c&s , 3p, 32 amp, bolted type switch disconnector fuse unit item code: cssdf32b3, make c&s , c&s make tpn, 32 amp , din type switch disconnector fuse unit item code: cssdf32d3n, make c&s , 2p, 63 amp, bolted type switch disconnector fuse unit item code: cssdf63b2, make c&s , 3p, 63 amp, bolted type switch disconnector fuse unit item code: cssdf63b3, make c&s , 2p, 63 amp , din type switch disconnector fuse unit item code: cssdf63d2, make c&s , tpn, 63 amp , din type switch disconnector fuse unit item code: cssdf63d3, make c&s , 3p, 63 amp , din type switch disconnector fuse unit item code: cssdf63d3n, make c&s , 3p, 100 amp , din type switch disconnector fuse unit item code: cssdf100d3, make c&s , 2p, 125 amp , din type switch disconnector fuse unit item code: cssdf125d2, make c&s , 3p, 125 amp , din type switch disconnector fuse unit item code: cssdf125d3, make c&s , 3p, 160 amp , din type switch disconnector fuse unit item code: cssdf160d3, make c&s , 3 pole, 400 amp , din type switch disconnector fuse unit item code: cssdf400d3, make c&s , control relay 10 amp with contact configuration ( 2no+2nc ) , with dc coil , item code tca3 dn22, make c&s , control relay 10 amp with contact configuration ( 3no+1nc ) , with dc coil item code tca3 dn31, make c&s , control relay 10 amp with contact configuration ( 4no ) , with dc coil item code tca3 dn40, make c&s , control relay 10 amp with contact configuration ( 2no+2nc ) , with ac coil item code tca2 dn22, make c&s , control relay 10 amp with contact configuration ( 3no+1nc ) , with ac coil item code tca2 dn31, make c&s , control relay 10 amp with contact configuration ( 4no ) , with ac coil, item code tca2 dn40, make c&s , heavy duty overload relay, independent mounting rtrip class 30, relay range ( 45 63 amp ) , item code tr6f63 , make m / s c&s...

Bharat Heavy Electricals Limited - Madhya Pradesh

30509082 e4313050 control relay as per enquiry , control relay 24vdc coil and 2no+2ncauxiliarycontacts & with inbuilt / clip in surgesupressor withoutany external wiring. either offollowing make & partnos to be only offered: group schneider ( cad32bd ) , siemens ( 3rh2122 1bb40 + 3rt2916 1eh00 ) , abb ( nl22e81 +rt5 / 32 ) or equivalent of l&t in mn0 or mo0 series withinbuilt / clip in surge suppressor only. note:vendor hasto quote for these part numbers onlyi.e. other partnumbers will not be accepted, m / s l&t tosubmit fullpart no. of the offered items of mn0 or mo0series , control relay 24vdc coil and 4no auxiliary contacts&with inbuilt / clip in surge supressor withoutanyexternal wiring. either of following make & partnos tobe only offered: group schneider ( cad50bd ) , siemens ( 3rh2140 1bb40 + 3rt2916 1eh00 ) , abb ( nl40e81 +rt5 / 32 ) orequivalent of l&t in mn0 or mo0 series withinbuiltsurge suppressor only. note:vendor has to quote forthese part numbers only i.e. other part numberswillnot be accepted, m / s l&t to submit full part no. oftheoffered items of mn0 or mo0 series , control relay 24vdc coil and 6no+2ncauxiliarycontacts & with inbuilt / clip in surgesupressor withoutany external wiring. either offollowing make & partnos to be only offered: groupschneider ( cad50bd +ladn22 ) , siemens ( 3rh2140 1bb40 +3rh2911 1ga22 + 3rt2916 1eh00 ) , abb ( nl40e81 + ca5 22e +rt5 / 32 ) or equivalent of l&tin mn0 or mo0 series withinbuilt surge suppressor only .note:vendor has toquote for these part numbers onlyi.e. other partnumbers will not be accepted, m / s l&t tosubmit fullpart no. of the offered items of mn0 or mo0series , control relay 110vdc coil and 2no+2ncauxiliarycontacts & with inbuilt / clip in surgesupressor withoutany external wiring. either offollowing make & partnos to be only offered: groupschneider ( cad32fd ) , siemens ( 3rh2122 1bf40 + 3rt2916 1eh00 ) , abb ( nl22e86 +rt5 / 150 ) or equivalent of l&t in mn0 or mo0 series withinbuilt surge suppressor only. note:vendor has toquote for these part numbers only i.e. other partnumbers will not be accepted, m / s l&t to submitfullpart no. of the offered items of mn0 or mo0 series. , control relay 110vdc coil and 5no+3ncauxiliarycontacts & with inbuilt / clip in surgesupressor withoutany external wiring. either offollowing make & partnos to be only offered: groupschneider ( cad32fd +ladn31 ) , siemens ( 3rh2122 1bf40 +3rh2911 1ga31 + 3rt2916 1eh00 ) , abb ( nl22e86 + ca5 31e +rt5 / 150 ) or equivalent ofl&t in mn0 or mo0 series withinbuilt surge suppressoronly . note:vendor has toquote for these part numbersonly i.e. other partnumbers will not be accepted, m / sl&t to submit fullpart no. of the offered items of mn0or mo0 series , control relay 110vdc coil and 6no+2ncauxiliarycontacts & with inbuilt / clip in surgesupressor withoutany external wiring. either offollowing make & partnos to be only offered: groupschneider ( cad50fd +ladn22 ) , siemens ( 3rh2140 1bf40 +3rh2911 1ga22 + 3rt2916 1eh00 ) , abb ( nl40e86 + ca5 22e +rt5 / 150 ) or equivalent ofl&t in mn0 or mo0 series withinbuilt surge suppressoronly. note:vendor has to quote for these part numbersonly i.e. other part numbers will not be accepted, m / sl&t to submit full part no. of the offered items of mn0or mo0 series , 24 vdc on time delay relay with 1co contact.eitheroffollowing make & part nos to be onlyoffered:siemens ( 3rp 1513 1aq308k ) , schneider ( re17ramu ) , abb ( ctere / 1sver550107r2100 ) , l&t ( 11odt4 ) ....

South Eastern Coalfields Limited - Madhya Pradesh

30379676 bids are invited for 122m3755753p 3 pole oil dashpot relay 150/5 , 122m1502003003p 3 pole oil dashpot relay 200/5 , 122m2253004503p 3pole oil dashpot relay 300/5 , vulcan vaccum circuit breaker 3.3kv , heat heater , 120300515 current transformer for o/l , botp6 mcb , boplaco2 control relay , am ammeter , 650605 vcb shunt trip coil , 650405 vcb closing coil , 650400 vacuum interrupter , dcpp dc power pack , lab9vcb33 indicating lamp , boss90375 push button element 1 no +1 nc , bosrp137b test run switch , euvr1 under voltage relay 110v , cbt90m core balance transformer , cbt80m core balance transformer , vmso65 voltmeter , lat2001005 current transformer , 130a0150sov33 ammeter 150/5 for vcb , 130a0200sov33 ammeter 200/5 for vcb , elm7lats earth leakage relay 50 750ma with time lag , elm7dlats80m earth leakage relay 50ma 750ma & 750ma 2a dual setting with time lag with cbct total quantity : 1...

Madhya Pradesh Power Transmission Company Limited - Madhya Pradesh

30147171 procurement of ehv grade i transformer oil procurement of ehv grade i transformer oil , electrical items : , ehv grade i transformer oil for power transformers conforming to all technical particulars as detailed out in annexure i ( volume ii ) attached. the oil should be supplied in road tankers with nitrogen cushioning under positive pressure , ( b ) structure for item 3 ( a ) above , ( a ) 36 kv gapless lightning arrester with terminal connector meeting the technical requirement as per section – iii, annexure iii , ( b ) structure for item 4 ( a ) above , ( a ) 33 kv isolator with earth switch complete with insulators & all accessories meeting the technical requirement as per section – iii, annexure iv , ( b ) structure for item 5 ( a ) above , 33 kv vacuum circuit breaker with structure meeting the technical requirement as per section – iii, annexure v , 33 kv control & relay panel meeting the technical requirement as per section – iii, annexure vi , 33 kv bolted type post insulator structure complete with 33 kv post insulators meeting the technical requirement as per section – iii, annexure vii...

Madhya Pradesh Power Generating Company Limited - Madhya Pradesh

30070271 procurement of l andt make lv components for various lt mcc s panels at 2x600mw, sstpp, mppgcl, khandwa procurement of l andt make lv components for various lt mcc s panels at 2x600mw, sstpp, mppgcl, khandwa , switch disconnector fuse unit (tpn) , sfu fnx 100 , sfu fnx 125 , sfu fnx 160 , sfu fnx 250 , sfu fnx 315 , power contactor (coil volt 240vac) with auxiliary contacts , 3 pole, 22a ac power mnx 22 , 3 pole, 25aac power mnx 25 , 3 pole ,50aac power mnx 50 , 3 pole ,70a ac power mnx 70 , 3 pole 80a ac power mnx 80 , 3 pole, 110a ac power mnx 110 , 3 pole,140a ac power mnx 140 , 3 pole ,300a,ac power mnx 300 , 3 pole ac power ml 12 (300a) , power contactor (coil volt 415vac) with auxiliary contacts , 3 pole,18a, ac power mnx 18 , power contactor (coil volt 240vdc) with auxiliary contacts , 3 pole dc power mx 09 , auxiliary control relay , mx0 22e (coil volt 240 vac) , mx0 40e (coil volt 240 v dc) , add on block , mo ta4 (2no+2nc) , mnx a1 (3no+1nc) , mnx a2 (1no+3nc) , mx a1 (2no+2nc) , overload relay , mn2 range 0.6 1a , mn2 range 0.9 1.5a , mn2 range 1.4 2.3a , mn2 range 4.5 7.5a , mn2 range 6 10a , mn2 range 9 15a , mn2 olr mounting kit , motor protection relay (16 44a)...

Madhya Pradesh Power Transmission Company Limited - Madhya Pradesh

29865576 procurement of overhead transmission line off line fault locator with signature analyzer system procurement of overhead transmission line off line fault locator with signature analyzer system ( tr 43 / 2021 ) , supply of following categories of testing equipments complete with all accessories as described in the section ii of the specification , overhead transmission line off line fault locator with signature analyzer system , ( b ) structure for item 3 ( a ) above , ( a ) 36 kv gapless lightning arrester with terminal connector meeting the technical requirement as per section – iii, annexure iii , ( b ) structure for item 4 ( a ) above , ( a ) 33 kv isolator with earth switch complete with insulators & all accessories meeting the technical requirement as per section – iii, annexure iv , ( b ) structure for item 5 ( a ) above , 33 kv vacuum circuit breaker with structure meeting the technical requirement as per section – iii, annexure v , 33 kv control & relay panel meeting the technical requirement as per section – iii, annexure vi , 33 kv bolted type post insulator structure complete with 33 kv post insulators meeting the technical requirement as per section – iii, annexure vii...

National Judicial Academy - Madhya Pradesh

29740322 supply of electrical equipment for 33 kv electrical sub station in the academy supply of electrical equipment for 33 kv electrical sub station in the academy , supply of electrical equipment for 33 kv electrical sub station in the academy , 33 kv vcb, outdoor porcelain clad type with complete structure and accessories. crompton greaves / abb / bhel , 33 kv ct outdoor oil immersed type 3 core, 300 150 / 5 5 amp, class 0.5. crompton greaves / abb / bhel , 33 kv control & relay panel with static relay for transformer protection. crompton greaves / abb / bhel , 33 kv control & relay panel with static relay for feeder protection. crompton greaves / abb / bhel , 33 kv 3x150 sq mm xlpe cable. finolex / polycab...

Madhya Pradesh Power Transmission Company Limited - Madhya Pradesh

29716458 supply installation commissioning and testing of 06 no. split ac of 2.0 tr capacity with 03 star and above rating supply installation commissioning and testing of 06 no. split ac of 2.0 tr capacity with 03 star and above rating , ac equipment : , supply, installation & commissioning of 2.0 tr capacity split air conditioners with 3.0 star and above rating including all accessories ( electric fittings, clamps, fasteners, additional copper piping, mcb etc. ) for sub ld & backup sldc, mpptcl, bhopal out of preferred makes i.e. blue star, voltas, hitachi, lg, haier, samsung , carrier & forbes only ( latest model ) . , ( b ) structure for item 3 ( a ) above , ( a ) 36 kv gapless lightning arrester with terminal connector meeting the technical requirement as per section – iii, annexure iii , ( b ) structure for item 4 ( a ) above , ( a ) 33 kv isolator with earth switch complete with insulators & all accessories meeting the technical requirement as per section – iii, annexure iv , ( b ) structure for item 5 ( a ) above , 33 kv vacuum circuit breaker with structure meeting the technical requirement as per section – iii, annexure v , 33 kv control & relay panel meeting the technical requirement as per section – iii, annexure vi , 33 kv bolted type post insulator structure complete with 33 kv post insulators meeting the technical requirement as per section – iii, annexure vii...

Madhya Pradesh Power Transmission Company Limited - Madhya Pradesh

29698436 retender for erection of augmentation from 220 / 132kv, 125mva by 220 / 33kv, 200mva x mer at 220kv s / s mpptcl nagda with related equipment and accessories at 220kv s / s nagda under tandc circle nagda 1 erection of 200mva 220 / 132kv x mer with all associates accessories with radiators, marshalling box, conservator etc. 2 dismantling of125 mva 220 / 132 kv transformer with all associated accessories with radiators, marshalling box , bushings , conservators etc. & shifting to all associated accessorieson safe location 3 erection 220 kv circuit breaker 4 erection 220 kv current transformer 5 erection 220 kv lightning arrestor 6 erection 220 kv pt 7 erection 220 kv isolator without earth switch 8 erection 220 kv control & relay panel 9 erection 220 kv post / solid core insulator 10 erection 132 kv isolator without earth switch 11 erection 132 kv current transformer 12 erection 132 kv lightning arrestor 13 erection fixing of ct junction box ( 36 way ) 14 erection fixing of ct junction box ( 64 way ) 15 erection 220 kv main bus structure07 no. 16 erection 220 kv ct structure03 no. 17 erection 220 kv la structure 03 no. 18 erection 220 kv pistructure 45 no. 19 erection 220 kv isolator structure 11 no. 20 erection 220 kv ptstructure03 no. 21 erection 132 kv isolator without earth switch01 no. 22 dismantling of 220 kv la 23 dismantling of 132 kv ct 24 dismantling of 132 kv la 25 dismantling of 132 kv isolator without earth switch 26 dismantling of structure220 kv lastructure03 nos. 27 dismantling ofstructure 132 kv isolator without earth switch 01 no. 28 stringing & jumpring of single zebra conductor 29 stringing & jumpring of double zebra conductor 30 stringing & jumpring of screening conductor with associate gantry coloumn 31 cable laying 2 core 2.5 sq.mm unarmored 32 cable laying 4 core 2.5 sq.mm unarmored 33 cable laying 8 core 2.5 sq.mm unarmored 34 cable laying 12 core 2.5 sq.mm unarmored 35 cable laying 19 core 2.5 sq.mm unarmored 36 cable termination 2.5 sq. mm. 2 core 5cable 37 cable termination 2.5 sq. mm. 4 core 60 cable 38 cable termination 2.5 sq. mm. 8 core 10 cable 39 cable termination 2.5 sq. mm. 12 core04 cable 40 cable termination 2.5 sq. mm. 19 core 10 cable 41 installation of 25mm dia 3000mm long ms rod earth electrodes by directly driving / drilling ( 6” dia ) in to earth including excavation ( irrespective of type of soil encountered ) back filling with mennonite soil, welding to earth conductor etc. 42 m.s. flat ( 75 x8mm ) 43 m.s. flat ( 65x8mm ) 44 m.s. flat ( 50x6mm ) 45 preparation of earth pit ( 1.5x1.5x3mtr ) as per boards drawing no. xii –b 774 which includes excavation ( irrespective of the sol encountered ) embedding of 4 nos. gi pipes of size 40 mm dia 3 meters long, back filling with black cotton soil free from boulders and harmful mixture. these gi pipes are to be welded with m.s flats by making mesh frame and cutting of pipes as also making holes in the pipe for water seepage. the earth pit is to be connected with earth mash of m.s. flat. ( g.i. pipe will be provided by mpptcl ) ....